1 Page1 2010 Dynapack GHG Reduction

2 Page2 GHG Reduction Plan Purpose: To reduce GHG emissions and offer a comfortable, healthy work environment. Scope: Investigate the facilities of Dynapack and improve its efficiency to reduce the GHG emission. Target: Reduce CO2e 1.29% of current emission in 2010 improvement activities. In 2010 inventory, Dynapack have9797.40 tonnes CO2e/Year.

3 Page3 GHG Reduction Plan Plan: Jan~Dec’10 1. Utilize Car Pool - To Reduce Car Traveling between Dynapack sites and suppliers’ site. 2. Reduce Lights Usage - Illumination improvement and then reduce the lights and light starters to save electricity usage. 3. Add frequency conversion air compressor - Add frequency conversion air compressor and save electricity usage. 4. Power reduction - The improvement of ventilation system. 5. Water reduction - Rebuild bathroom faucet

4 Page4 Identify the Concept of Scope Scope 1: Direct GHG emissions occur from sources that are owned or controlled by the company, for example, emissions form combustion in owned or controlled boilers, furnaces, vehicles, etc.; emissions from chemical production in owned or controlled process equipment. Scope 2: GHG emissions from the generation of purchased electricity consumed by the company. Purchased electricity is defined as electricity that is purchased or otherwise brought into the organizational boundary of the company.

5 Page5 Organizational & Operational Boundaries Dynapack Taiwan KunshanWujiang Scope 1Scope 2Scope 1Scope 2Scope 1 Purchased Electricity TransportationPurchased Electricity TransportationPurchased Electricity CO2 CH4 N2O

6 Page6 Plan-1 : Utilize Car Pool to Reduce Car Traveling - Reduce 72.925 tonnes CO2e/year Note : 2.63kg CO2e/L of diesel 2.3 kg CO2e/L of gasoline 20092010 Reduce CO2e/year (Tonnes) Diesel Usage (L)7117090890 72.925 Gasoline Usage (L)2157336458 CO2e (kg) of Diesel187177.1239040.7 CO2e (kg) of Gasoline49617.983853.4 CO2e (kg) of total236795322894.1 Output(PCS)1508133625146713 CO2e (Kg) of one PCS0.01570.0128

7 Page7 Plan-2 : Reduce Lights Usage - Reduction: 2.919 tonnes CO2e/year ItemLight ReductionDescription Reduce CO2e 1 Illumination improvement- Reduce the lights and light starters to save electricity usage 2.919tonnes AreaNO. of light Reduce Hrs (H) Power(W)Day Energy saving (KWh) Reduce CO2e (tonnes) Workshop 661093652168.1002.162 OFFICE AREA 21119365758.8350.757 Note : 0.997 kg CO2e/KWh, Taiwan Power Corporation, www.taipower.com.twwww.taipower.com.tw Result :

8 Page8 Plan-3 : Add frequency conversion air compressor - reduce 15.808 tonnes CO2e/year Note : 0.997 kg CO2e/KWh ItemDescription Est energy saving Reduce CO2e (tonnes/year) 1 Add frequency conversion air compressor 15855.6 KWh/year15.808

9 Page9 Plan-4 : Power reduction - reduce 34.423 tonnes CO2e/year Note : 0.997 kg CO2e/KWh, Taiwan Power Corporation, www.taipower.com.tw www.taipower.com.tw ItemDescription Est energy saving Reduce CO2e (tonnes/year) 1 The improvement of ventilation system 34527.06 KWh/year34.423

10 Page10 Plan-5 : Water reduction - reduce 0.339 tonnes CO2e/year Note : Reduced 0.194 kg CO2e / tonne water ItemDescription Water energy saving Reduce CO2e (tonnes/year) 1 Rebuild bathroom faucet 1749.6 T/year0.339

11 Page11 2010 Dynapack CO2e Reduction DescriptionReduce CO2e (Tonnes/Year) Est. Total CO2e Reduction (Tonnes/Year) Plan 1Car pool72.925 126.414 Plan 2Reduce light & light starter 2.919 Plan 3Add frequency conversion air compressor 15.808 Plan 4The improvement of ventilation system 34.423 Plan 5 Rebuild bathroom faucet 0.339

12 Page12 Summary and Future Plan 2010 GHG Reduction Result: Reduced 1.29% ( 126.414 tonnes/9797.40 tonnes) CO2e through 2009 improvement activities. Future Plan: 1% emission reduction per year. a. Power reduction. (Reduce overtime, lighting) b. Fuel usage reduction. (Transportation reduction due to overtime reduction)