Rest and Stress Systems NetECG Systems Holter Systems PC Based ECG Systems.

Similar presentations


Presentation on theme: "Rest and Stress Systems NetECG Systems Holter Systems PC Based ECG Systems."— Presentation transcript:

1

2 Rest and Stress Systems NetECG Systems Holter Systems PC Based ECG Systems

3  Wireless (Bluetooth ® ) communication  Integrated 3D motion detection  Pacemaker Detection  Low Power Consumption  Greyscale LCD Holter Systems  1, 2, 3 independent channels or 12-CH ECG New Holter ECG Recorder

4  Wireless (Bluetooth ® ) communication  Integrated 3D motion detection  Pacemaker Detection  Low Power Consumption  Greyscale LCD  1, 2, 3 independent channels or 12-CH ECG New Holter ECG Recorder Holter Systems

5  Recording duration: 24, 48, 72 hours, 1 week  Recording rate: 128, 256, 512, 1024 Hz  ADC resolution: 16 bit  Dynamic range: +/- 20 mV  CMRR: 120dB  Powered by only 1 AAA battery Holter Systems

6  Recording duration: 24, 48, 72 hours, 1 week  Recording rate: 128, 256, 512, 1024 Hz  ADC resolution: 16 bit  Dynamic range: +/- 20 mV  CMRR: 120dB  Powered by only 1 AAA battery

7 Holter Systems New USB-02 Wireless Interface  Fully compatible with Windows ® XP, Vista, and 7 (32/64 bit)  Wireless Bluetooth ® connection  Simple, quick pairing  Convenient, reliable, easy to use

8  Electrode connection check before recording  Effective filtering method  Effective filtering method Good quality ECG signal Holter Systems

9 Fast and reliable analysis with editing possibilities  Precise QRS detection  QRS template classification

10 Holter Systems Several types of computed parameters  Arrhythmia analysis  HR and Patient motion graphs  HR and Patient motion graphs  SAECG  ST level and slope  QT, QTc graphs

11 Holter Systems Several types of computed parameters  Atrial fibrillation  Heart rate turbulence  Microvolt T alternans  Pacemaker analysis  Blood pressure graphs  HRV time and frequency

12 Internet Holter Systems Informatics support  Network application  Record, report forwarding  Interfaces CLIENT SERVER Record FTP Server CLIENT SERVER Email Server Record

13 Rest and Stress Systems NetECG Systems Holter Systems PC Based ECG Systems

14 Wireless Resting And/Or Stress Test Device  Low Power Consumption  12 channels resting and/or stress ECG  Wireless Bluetooth ® connection  Built-in Blood Pressure Monitor  Small size, compact build-up  Dynamic range: +/-20 mV  Sampling rate: 1000 Hz  Frequency response: 0.05 … 150 Hz  A/D resolution: 16 bit  Powered by 2 AA batteries  CMRR: 120 dB Rest and Stress Systems

15 Resting ECG  5, 10, 20s and long record (up to 7 hrs)  5, 10, 20s and long record (up to 7 hrs)  Built-in diagnostic system  Built-in diagnostic system  Comparison of ECG records  Comparison of ECG records

16 Rest and Stress Systems Large ergometer and treadmill database  17 ergometer, 18 treadmill protocols  17 ergometer, 18 treadmill protocols  MasterStep protocol  Walking protocol

17 Rest and Stress Systems Several types of computed parameters  HR, BP  Double product, MET  SAECG  ST level and slope, HR- ST loop  ST level and slope, HR- ST loop  Several kinds of printable reports  Several kinds of printable reports

18 Rest and Stress Systems Alarm and stop criterias  Heart rate  ST level  BP systole  BP diastole

19 Internet Informatics support  Network application  Record, report forwarding  Interfaces CLIENT SERVER Record FTP Server CLIENT SERVER Email Server Record Rest and Stress Systems

20 NetECG Systems Holter Systems PC Based ECG Systems

21 Platform Android is a trademark of Google Inc. NetECG Systems

22

23 The product is ideal to use in an emergency car, because: „The tablet is easy to use, it is small and mobile.” „Wireless technology eliminates the inconvenience of using cables.” „Records are easy to upload to an emergency centre where they are immediately evaluated by Cardiospy’s „cloud” application.” „It immediately provides feedback on the patient’s condition.” „It performs a preliminary analysis of the patient on his way to the hospital.” „The patient receives the appropriate treatment sooner as patient registration takes less time.”


Download ppt "Rest and Stress Systems NetECG Systems Holter Systems PC Based ECG Systems."