Presentation is loading. Please wait.

Presentation is loading. Please wait.

Building Core Elements and Design

Similar presentations


Presentation on theme: "Building Core Elements and Design"— Presentation transcript:

1 Building Core Elements and Design

2 The typical floor plate of the standard commercial office structure contains the following:
Vertical Circulation Core Open Lease Space Optional public corridor.

3 Building Core Core

4 Lease Area Core Tenant Lease Space

5 Lease Depth Core Lease Depth Tenant Lease Space

6 Optional Corridor Core Lease Depth Tenant Lease Space

7 Tenant Lease Area

8 Elements of the Building Core

9 The Building Core of the Commercial building contains
Passenger Elevators & Lobby

10 The Building Core of the Commercial building contains
Passenger Elevators & Lobby Service Elevator

11 The Building Core of the Commercial building contains
Passenger Elevators & Lobby Service Elevator Service Elevator Vestibule

12 The Building Core of the Commercial building contains
Passenger Elevators & Lobby Service Elevator Service Elevator Vestibule Mechanical Room

13 The Building Core of the Commercial building contains
Passenger Elevators & Lobby Service Elevator Service Elevator Vestibule Mechanical Room Vertical Chase

14 Passenger Elevators & Lobby
M W

15 Service Elevator M W

16 Service Elevator Vestibule
M W

17 Mechanical Room M W

18 Vertical Chase M W

19 The Core also consists of
Fire Egress Stairs

20 The Core also consists of
Fire Stairs Restrooms

21 The Core also consists of
Fire Stairs Restrooms Drinking Fountain Vestibule

22 Fire Egress Stairs M W

23 Public Restrooms M W

24 Public Restrooms M W

25 Core Location The Building Core can take any of basic locations relative to the floor plate. Central Core Off- set Core Exterior Core Split Core

26 Central Core Location In the central core the lease depth is relatively equal around the core of the building.

27 Central Core Location

28 Central Core Location

29 The Tenant can lease the entire floor plate
Central Core Location In the central core the lease depth is relatively equal around the core of the building. The Tenant can lease the entire floor plate

30 Central Core Location Core Lease Depth Tenant Lease Space

31 Or the tenant can lease a portion of the floor plate.
Core Location Or the tenant can lease a portion of the floor plate.

32 Central Core Location Core Lease Depth Tenant Lease Space

33 Bruce Graham John Hancock Bldg. Chicago, Ill.
Central Core Location Bruce Graham John Hancock Bldg. Chicago, Ill.

34 Frank Gehry New York Times Headquarters
Central Core Location Frank Gehry New York Times Headquarters

35 Central Core Location

36 Core Location

37 Off- Set Core Location The off Set-Core places the core off center creating differing lease depths.

38 Off- Set Core Location Lease Depth 1 Lease Depth 2 Core Lease Depth 3

39 This provides greater leasing options.
Off- Set Core Location The off Set-Core places the core off center creating differing lease depths. This provides greater leasing options.

40 Off- Set Core Location Lease Depth 1 Core Lease Depth 2

41 Henry Cobb Electicite de France Paris, France
Off- Set Core Location Henry Cobb Electicite de France Paris, France

42 Jean Nouvel Torre Agbar Barcelona, Spain
Off- Set Core Location Jean Nouvel Torre Agbar Barcelona, Spain

43 Split Core Location The Split core divides the core with a central space, all components of the core are accessed from this central space.

44 Split Core Location Core Core Tenant Lease Space

45 Split Core Location

46 Off- Set Core Location This eliminates the need for any peripheral access corridor and lease space can extend right up to the walls of the core elements.

47 Split Core Location Tenant Lease Space Core Core

48 Murphy / Jahn, Deutsche Post
Split Core Location Murphy / Jahn, Deutsche Post

49 Cesar Pelli International Finance Center II
Split Core Location Cesar Pelli International Finance Center II

50 Split Core Location The Split Core can be divided in any number of ways. It should be noted that this increases the depth of the core and therefore the size of the floor plate.

51 Split Core Location Core Core Core Core Tenant Lease Space

52 Split Core Location The lease area can here too be divided but access must still be maintained to two means of egress in case of fire.

53 Split Core Location Tenant Lease Space Core Core Core Core

54 Split Core Location Norman Foster Swiss Re

55 Split Core Location

56 Exterior Core Location
In the Exterior Core configuration the core is pulled either to one side or edge. If the core is pushed to one side creating a ‘dead wall’ this can be used to advantage where poor views or party walls present a problem.

57 Exterior Core Location
Tenant Lease Space

58 Michael Graves Humana Bldg.
Exterior Core Location Michael Graves Humana Bldg.

59 Exterior Core Location

60 Norman Foster Commerzbank
Exterior Core Location Norman Foster Commerzbank

61 Exterior Core Location
Steven Holl 5th Ave. & 42nd

62 Exterior Core Location

63 Exterior Core Location
The Core can also be isolated as a separate mass element independent from the lease floor plate.

64 Exterior Core Location
Tenant Lease Space Core Core

65 Richard Rodgers, 122 Leadenhall St.
Exterior Core Location Richard Rodgers, 122 Leadenhall St.

66 Richard Rodgers Lloyds of London
Exterior Core Location Richard Rodgers Lloyds of London

67 Exterior Core Location

68 Elevator Configurations in Tall Buildings
Different banks of elevators serve different floors A B 1-20 21-40

69 Elevator Configurations in Tall Buildings
Unused Elevator lobbies are used to hold core elements such as restrooms or mechanical M M Lobby W W

70 Elevator Configurations in Tall Buildings

71 Elevator Configurations in Tall Buildings

72 Elevator Configurations in Tall Buildings
Elevator banks drop out of the core as they are no longer needed.

73 Elevator Configurations in Tall Buildings
As elevator banks drop out the space becomes lease space or the floor plate is reduced Lease Space Lobby

74 Elevator Configurations in Tall Buildings
The reduction in the core due to the drop out of elevator banks allows for the increase of lease space or reduction of floor plate allowing the building to “taper”.

75 Elevator Configurations in Tall Buildings
It may become necessary to relocate the fire egress stairs to maintain efficiency of the lease space or for design purposes Lobby

76 Elevator Configurations in Tall Buildings
Fire egress stairs can be are transferred horizontally

77 Elevator Configurations in Tall Buildings
To minimize the square footage of the core on very tall buildings architects can stack the elevator banks and use express elevators to sky lobbies. Banks of elevators service only a set of designated floors while movement between them is achieved by the express system.

78 Elevator Configurations in Tall Buildings
Minoru Yamasaki World Trade Center

79 Lease space can be arranged in basically two general configurations:
Lease Space Planning Lease space can be arranged in basically two general configurations: Perimeter Office Executive Core

80 Their views make them prime locations
Lease Space Planning The Perimeter Office In the perimeter office, private managerial offices line the outside wall of the building. Their views make them prime locations

81 Lease Space Planning Core Tenant Lease Space

82 Lease Space Planning The corners of the building are then the most sought after. These are often reserved for the highest staff level. Architects often facet the buildings corners to create more corner offices.

83 Lease Space Planning The Executive Core Increasingly we see the introduction of the executive core which moves the executive offices to the center of the floor plate. This allows greater light penetration and maximizes the number of people who get a view.

84 Lease Space Planning Core Tenant Lease Space

85 The typical residential core is smaller
Residential Cores The typical residential core is smaller because it will usually not require as many elevators and there is no need for the public restrooms.

86 The Residential Core consists of Fire Stairs
Residential Cores The Residential Core consists of Fire Stairs

87 The Residential Core consists of Fire Stairs Elevator Lobby
Residential Cores The Residential Core consists of Fire Stairs Elevator Lobby

88 The Residential Core consists of Fire Stairs Elevator Lobby
Residential Cores The Residential Core consists of Fire Stairs Elevator Lobby Service Elevator

89 The Residential Core consists of Fire Stairs Elevator Lobby
Residential Cores The Residential Core consists of Fire Stairs Elevator Lobby Service Elevator Vestibule

90 The Residential Core consists of Fire Stairs Elevator Lobby
Residential Cores The Residential Core consists of Fire Stairs Elevator Lobby Service Elevator Vestibule Mechanical Room

91 The Residential Core consists of Fire Stairs Elevator Lobby
Residential Cores The Residential Core consists of Fire Stairs Elevator Lobby Service Elevator Vestibule Mechanical Room Trash Chute

92 Residential Cores

93 Residential Cores

94 It is common to push all major spaces to the perimeter.
Residential Layouts It is common to push all major spaces to the perimeter. Closed spaces such as bathrooms, closets mechanical closets, and kitchens are often pushed toward the core.

95 Residential Cores

96 It also allows for maximum light penetration
Residential Cores This is because code calls for all major rooms to be accessible to the perimeter for fire rescue. It also allows for maximum light penetration

97 Residential Cores


Download ppt "Building Core Elements and Design"

Similar presentations


Ads by Google