Siemens Applied Automation Process Gas Chromatography NeSSI – Lets Do It.pptSlide 1; IFPAC; February 22, 2006 Let’s Do It! Using NeSSI IFPAC: February.

Similar presentations


Presentation on theme: "Siemens Applied Automation Process Gas Chromatography NeSSI – Lets Do It.pptSlide 1; IFPAC; February 22, 2006 Let’s Do It! Using NeSSI IFPAC: February."— Presentation transcript:

1 Siemens Applied Automation Process Gas Chromatography NeSSI – Lets Do It.pptSlide 1; IFPAC; February 22, 2006 Let’s Do It! Using NeSSI IFPAC: February 2006

2 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 2; IFPAC; February 22, 2006 Process Gas Chromatography A Bit Of Philosophy Some projects are easy to get started: A clear goal One way to proceed with one set of benefits and problems A clear task to do Some projects are more difficult to get started: Various overlapping objectives Multiple, valid ways to proceed with differing benefits and problems Several tasks to be accomplished This is particularly true when the benefits and problems must be estimated and you are lacking in practical experience because you’re dealing with a new idea.

3 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 3; IFPAC; February 22, 2006 Process Gas Chromatography So What Does a Project Manager Do?  Stick to a schedule  Stick to a budget  Sometimes, you need to do something – maybe ANYTHING – even if it’s not perfect – in order to get things going.  This can be true EVEN if you’re dealing with possible rework later on.  On a project intended to result in the benefits of doing a thing better: ► The costs continue to occur even if you do nothing; ► The benefits NEVER occur if you do nothing!

4 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 4; IFPAC; February 22, 2006 Process Gas Chromatography Sometimes… …you just have to shoot the engineer and start production.

5 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 5; IFPAC; February 22, 2006 Process Gas Chromatography The NeSSI Vision SAM HMI Dumb Analyzer Smart Analyzer HMI SAM HMI Air Power Air Power

6 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 6; IFPAC; February 22, 2006 Process Gas Chromatography The Vision – One More Point SAM HMI Dumb Analyzer Ax

7 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 7; IFPAC; February 22, 2006 Process Gas Chromatography The NeSSI Vision SAM HMI Dumb Analyzer Smart Analyzer HMI SAM HMI Air Power Air Power

8 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 8; IFPAC; February 22, 2006 Process Gas Chromatography Doing This Today Dumb Analyzer Smart Analyzer HMI Air Power Air Power Air

9 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 9; IFPAC; February 22, 2006 Process Gas Chromatography The Benefits  Reduced Cost ► Size – space consumption ► Utility consumption ► Engineering ► Assembly ► Maintenance  Higher Availability ► Better intrinsic reliability ► Higher MTBF ► Shorter MTTR ► Reduced training cost for maintenance / repair ► Parallel paths – back up hardware – fail-safe design  Improved Performance ► Reduced volumes ► Shorter flow paths ► Other?

10 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 10; IFPAC; February 22, 2006 Process Gas Chromatography Pieces Of the NeSSI Idea  New mechanical components ► Modular ► Standardized mounting platform ► Interchangeable function  New electrical interconnection ► Serial connection – plug in ► Intrinsically safe ► Self-identifying components  New smart design features (SAM) ► Helpful HMI ► Programmability ► Standardized, transportable user programming

11 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 11; IFPAC; February 22, 2006 Process Gas Chromatography Tabulating the Benefits X X X X X X X X O X O XX X O X - X X X X

12 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 12; IFPAC; February 22, 2006 Process Gas Chromatography The NeSSI Vision SAM HMI Dumb Analyzer Smart Analyzer HMI SAM HMI Air Power Air Power

13 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 13; IFPAC; February 22, 2006 Process Gas Chromatography The NeSSI Vision – Partial Implementation PLC HMI Dumb Analyzer Smart Analyzer HMI SAM HMI Air Power Air Power Vendor selection: Fieldbus CAN Open I2C Other Vendor selection

14 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 14; IFPAC; February 22, 2006 Process Gas Chromatography A Bit More On the Bus Question  Fieldbus ► Advantages: Intended for field process use; well defined; widely deployed; device definition available; IS available… ► Disadvantages: ??; Join in costs; stack costs; development knowledge; support resources  CAN Open ► Advantages: Inexpensive; very rugged chip set; very widely deployed; device definition available ► Disadvantages: ??; IS not yet available; intended for automotive, not process  I2C or Other ► Advantages: Extremely inexpensive; very widely known; no development overhead; electrical devices defined ► Disadvantages: IS by third party; not originally intended for outside the box; device definitions may be limited

15 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 15; IFPAC; February 22, 2006 Process Gas Chromatography Another Note  The bus questions is only ONE of the issues awaiting standardization  The bus question is probably the LEAST difficult issue!

16 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 16; IFPAC; February 22, 2006 Process Gas Chromatography So again – so MUCH is there now… PLC HMI Dumb Analyzer Smart Analyzer HMI SAM HMI Air Power Air Power Vendor selection: Fieldbus CAN Open I2C Other Vendor selection

17 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 17; IFPAC; February 22, 2006 Process Gas Chromatography So – why wait?  Mechanical components are here  Electrical interface is here in a variety of forms ► NeSSI standard not agreed = > limited interchangeability = > some components not available ► Intrinsic safety not standardized = > field inspection required  SAM can be implemented by PLCs and some “smart” analyzers in a variety of ways ► HMI features controlled by PLCs ► Interchangeability of software modules is limited  So, there are some limitations that are not available until the NeSSI committee completes it’s actions ► Many valuable benefits are here, however  There might be a cost of retrofit in the future – IF it was desirable in the future to shift to a pure NeSSI standard ► The architecture and philosophy is available now ► Retrofit costs might not be extensive ► The retrofit itself is optional

18 Siemens Applied Automation NeSSI – Lets Do It.pptSlide 18; IFPAC; February 22, 2006 Process Gas Chromatography Conclusions  Users should implement with what is available now ► Use “closest available” from their preferred supplier ► Be sure “closest available” is in the same direction as NeSSI is going ► Don’t worry if “closest available” does not exactly match in the future ► Plan to field retrofit IF desirable and needed  Siemens ► Plans to support this approach using our available busses now ► Plans to continue to support the NeSSI efforts toward full standardization


Download ppt "Siemens Applied Automation Process Gas Chromatography NeSSI – Lets Do It.pptSlide 1; IFPAC; February 22, 2006 Let’s Do It! Using NeSSI IFPAC: February."