Presentation is loading. Please wait.

Presentation is loading. Please wait.

May 14, 2014 RAMSHORN POND DAM REHABILITATION PUBLIC INFORMATION SESSION PARE CORPORATION, FOXBORO, MA Allen R. Orsi, P.E., Managing Engineer.

Similar presentations


Presentation on theme: "May 14, 2014 RAMSHORN POND DAM REHABILITATION PUBLIC INFORMATION SESSION PARE CORPORATION, FOXBORO, MA Allen R. Orsi, P.E., Managing Engineer."— Presentation transcript:

1 May 14, 2014 RAMSHORN POND DAM REHABILITATION PUBLIC INFORMATION SESSION PARE CORPORATION, FOXBORO, MA Allen R. Orsi, P.E., Managing Engineer

2  Additional Evaluations  Proposed Design Approach  Additional Design Considerations OUTLINE

3  Upstream Membrane Option ADDITIONAL EVALUATIONS

4  Upstream Membrane Option ADDITIONAL EVALUATIONS

5  Toe Drain Impacts  Reviewed improvements provided by downstream toe drain  Existing Seepage Exit Gradient Factor of Safety = 1.2  With Toe Drain Exit Gradient Factor of Safety = 2.0  Dam safety practice designs for a Factor of Safety = 5.0 ADDITIONAL EVALUATIONS

6  Opinions of Cost  Significant cost impacts associated with contingencies and early stage of design ADDITIONAL EVALUATIONS

7  Recommended Approach  Upstream Cutoff Wall  Durability  Permittability  Schedule  Drawdowns ADDITIONAL EVALUATIONS

8  Proposed Site Plan DESIGN APPROACH

9  Proposed Spillway DESIGN APPROACH

10  Proposed Low Level Outlet DESIGN APPROACH

11  Proposed Upstream Wall DESIGN APPROACH

12  Proposed Parking DESIGN APPROACH

13  Proposed Public Access DESIGN APPROACH

14  Proposed Drainage DESIGN APPROACH

15  Control of Water  Drawdowns  Bypass / Flow Maintenance  Cofferdams  Construction Phasing  Detours / Road Closure  Public Access Information / Signage ADDITIONAL DESIGN CONSIDERATIONS