Schneider Electric is the Global Leader in Pre Fabricated Modular Solutions

Similar presentations


Presentation on theme: "Schneider Electric is the Global Leader in Pre Fabricated Modular Solutions"— Presentation transcript:

1 Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion

2 Schneider Electric is the Global Leader in Pre Fabricated Modular Solutions
In January 2014 Schneider Electric acquired AST Modular the global leader in pre fabricated modular and containerized and modular Data Centers AST leads the pre-fabricated Modular Data Center Market (>20% market share) Over 600 Data Center projects successfully executed to date Projects deployed in over 50 countries First company to build a Tier 3 multi-Container Data Center Pioneered the manufacturing of high quality purpose built containerized data centers (2001) AST customers include IT leaders including IBM, HP, Dell, and Silicon Graphics

3 Schneider Has Deep Experience in Delivering Pre Fabricated Solutions

4 Product Options

5 Our Products Include a Wide Variety of Standard and Pre-fabricated IT Room Solutions
SS Standard ISO MDC – Non-ISO SS Modular Rooms Smart Shelter 20’ & 40’ ISO -All in one containers -Multi container parks 25’ & 45’ NON ISO -All in one modules -Contiguous IT rooms Secure IT rooms -Indoor & Out Door -Secure and any size

6 3 Types of IT Modules for Different Applications
AST IT Modules Compact ISO All-in-One (20ft Enclosure,7Racks, UPS, PDU, Overhead DX Cooling, Standard ISO All-in-One (40ft Enclosure, up to 19 racks, PDU, overhead DX cooling Ruggedized Solutions for Industrial (40ft Enclosure, up to 19 racks, PDU, overhead DX cooling, Ruggedized versions available Multi-Bay IT Modules (25ft – 40ft enclosure, Non-ISO design for more space. Cooling options - In-Row CW Perimeter CW, Air Economizer Cooling, DCIM) Modular Room (20 x 45ft Enclosure,24 Racks, PDU, 3 Perimeter CRACs CW cooling, DCIM)

7 Walk Through Our Demo Module Outside
IT Module – Non ISO ”Wide Tall & Comfortable” Overview Non-ISO design is wider, taller, deeper than container and engineered to provide a spacious, functional workspace for IT personnel Efficient, scalable design allows for custom, multi-module configurations from 20 – 240 racks Multiple cooling solutions for chilled water, DX and air economization (In-row, Perimeter, End-of-Row) Robust frame design simplifies installation and ganging together Best option for a complete configurable space. Walk Through Our Demo Module Outside

8 Multi Module Designs IT Rooms are joined together to form an “open white space” IT room

9 Base Designs – IT Modules
IT Room Modules 90kW All-in-One (40ft Enclosure,10 Racks, UPS, PDU, In-Row DX Cooling, DCIM) 110kW Single Module (40ft Enclosure, 10 racks, PDU, In-Row CW cooling, DCIM) 205kW Single Module (53ft Enclosure,14 racks, PDU, In-Row CW cooling, DCIM) 240kW Dual Module (20 x 45ft Enclosure 22 Racks, PDU, In-Row CW cooling, DCIM) (20 x 45ft Enclosure,24 Racks, PDU, 3 Perimeter CRACs CW cooling, DCIM)

10 90 kW All in One Pre Fabricated Data Center (Non ISO)

11 10 Rack 90 kW N+1 “All in One” Wide Body”
Pre Fabricated Data Center

12 Staging Lobby and Electrical Room 415 Modular Power Distribution
IT Module Detail 2 bay, 24 Rack In-Row, 240kW shown 24 NetShelter Racks Aisle Containment 240kW cooling capacity 415V per rack (2N) Power monitoring, management and controls Fire detection and suppression Staging lobby for outside isolation Staging Lobby and Electrical Room 415 Modular Power Distribution In-Row Cooling Units

13 25’ 5 rack 30 kW N+1 “All in One”

14 20’ 3 rack 30 kW N+1 Data Comm Room

15 Smart Shelter™ Prefab Modular Room Example Phased Deployment View of (4)100 Rack IT Bays
Phase Racks Phase 3 Phase 2 100 Racks Phase 4 Gensets Chillers

16 Smart Shelter™ Secure Prefab Modular Rooms
Expandable rooms are secure, water, dust & fire proof thermally insulated modular IT rooms. Rooms are built sized to any requirement. Installed Indoors or outdoor. Shelters can be disassembled & relocated. Rooms can expanded in a clean method. No construction construction dust or debris affecting expansion while operating. Visiting customers experience a “clean room” secure IT white space.

17 Echain cable management
IT Module – ISO Shipping Container Schneider specific features Seismic Rack Mount Echain cable management Sliding Rail System 17

18 Base Designs - Power Modules
250kW 20ft Enclosure with UPS, Switchgear, cooling, DCIM 500kW 40ft Enclosure with UPS, Switchgear, cooling, DCIM 1.2 MW Skid mounted, UPS, Switchgear, DCIM Power Modules

19 Critical Output Switchboard Fire Suppression System
Enclosed Power Modules Air Conditioners 500kW Module Symmetra N+1 UPS(250/500kW) 5 min Runtime Switchboard w/ integrated ATS Power monitoring, management and controls Environmental cooling Fire Suppression UL Listed Critical Output Switchboard 500kW Symmetra PX UPS The goal was a complete Schneider Electric solution. These key components would likely be the same or similar components, equipment and systems that you might fine in an electrical room supporting today’s data centre. Most of the equipment can be serviced from the front. UPS: The Symmetra PX system can provide 500kW of UPS conditioned power or configured as N+1 for greater redundancy. The UPS System provides 5 minutes of runtime. Cooling: The InRow coolers provide the necessary temperature and humidity control for installation outdoors or indoors. These precision cooling machines provide a 2N configuration for the module. SquareD Switchgear: QED switchboards have been properly sized to delver the primary power to your mechanical equipment along with the necessary input power for the Symmetra PX UPS system. A set of PLC controlled breakers is configured as part of the primary switchboard to allow normally open and normally closed transition between utility and generator. All breakers with the switchgear are metered. In addition, Powerlogic Scada with a 21 inch touch screen display allows for access to this critical information at the touch of a screen. The 500kVA transformer is downstream of the output switchboard and provides the option of 480V to 415V to the IT loads. Management: Lastly, the module ships with a complete fire detection and suppression system along with physical threat and environmental management ( Netbotz). All system and equipment data is aggregated to a modbus gateway and available through an Ethernet switch with a fiber port Fire Suppression System Primary Switchboard

20 Skid Mounted Power Module
1.2 MW Skid Shown Allows for quick deployment within an existing building that is scalable for larger data centers. N+1 UPS MW UPS 5 min Runtime Switchboard w/ integrated ATS Power monitoring, management and controls

21 Cooling Modules Cooling Modules 500kW Hydronics Modules
(Support 3-250kW Chillers) 1000kW Hydronics Modules (Support kW Chillers) Chiller Skids & Enclosures Packaged Chiller, pump, and Tank with connecting piping 250kW – 1.2 MW Packaged Air Cooled Chillers - Options with and without free cooling Ecobreeze ISO frame 50kW increments up to 400kW of total cooling capacity (DCIM)

22 AST Cooling Offer – CW & DX (Pending UL Certification)
AST added Capability Chilled Water Block Unit – CWB kW Chilled water room cooling for prefabricated IT modules without raised floors Fits both ISO and Non-ISO prefab modules Designed to operate at higher water temperatures (15C) Top return with front supply air discharge Humidifier and electric reheat control options Hot Corridor Heat Exchanger– HCX kW - 40 kW Overhead cooling for prefabricated ISO IT modules Chilled Water or Direct Expansion No floor space - located over the racks and hot aisle/corridor Maintenance all done from hot aisle/corridor Requires chilled water plant or remote condensing unit

23 AST Cooling Offer – Air Economizer
Natural Free Cooling Unit – NFC 50 kW Indirect Free Cooling for small or constrained data center spaces Independent operating unit Heat Pipe heat exchanger isolating indoor and outdoor air Chilled Water, Direct Expansion, Humidity Control and Evaporative Cooling Options Flexibility to have external heat rejection for mechanical cooling as required - Chilled Water Plant or External Condensing Units Direct Free Cooling Unit – DFC 75 kW Direct Free Cooling for small or constrained data center spaces Uses air directly from outside for free cooling Chilled Water, Direct Expansion, Humidity Control and Evaporative Cooling Options Flexibility to have external heat rejection for mechanical cooling as required - Chilled Water Plant or External Condensing Units

24 Global References Education - Canada Utility - Australia
Healthcare - Italy Military - Europe

25 Global References IT Software Company Government Customer – US
Global Bank – Denmark Cloud Service Provider – Iceland

26 Mission-Critical Services
Consulting and Planning – Assessment, analysis, strategic planning and O&M program development services. Design and Construction– Engineering, design-build and construction project management of facility expansions and new facility projects. Commissioning – Data center and LEED commissioning from project inception to integrating testing. Operations and Maintenance – Managed Services and on-site Critical Facility Management. Energy Management– Energy assessments, system optimization, and efficiency improvement projects. Alarm and Incident Management – 24x7 remote monitoring services through the Schneider International Operations Center (NOC). Schneider Electric offers a suite of service solutions for the entire lifecycle of the data center. Lifecycle Service Solutions

27 Design-Build Benefits
2/2012 12/2013 Schneider Design Build Outcomes Singular Accountability/Project Ownership Fully Integrated Project Delivery Speed to Market – Reduced Project Timelines Fewer Change Orders – Less Cost Overruns Continuous Project Budgeting and Scheduling Datacenter/Mission Critical Specific Team Skill Set Competitively Bid All Major Cost Items

28 Discussion, Questions and Answers
Thank you Scott Fleming Pre Fabricated Data Center Specialist (925)

29 IT Module – ISO Shipping Container
Overview ISO shipping container is defined to 8ft wide and lengths of 10ft, 20ft, 40ft, and 53ft in U.S. Containers are designed to be strong, rugged, environmentally sound and easily transportable anywhere in the world 8ft width limits usable space for hot and cold aisles. Height is also limited Schneider has unique solutions for slide racks and flexible cable trays to allow full access to front and rear of racks to overcome space limitations Overhead cooling units (DX and CW) are available to maximize rack space

30 DX – Chilled Water – Direct Air – Indirect Air
One-Size Does Not Fit All Power 200kW – 1.2MW IT Space 5 Racks – 200 Racks Cooling DX – Chilled Water – Direct Air – Indirect Air