MAGNETIC AND ARTICULATING (MNA) BOUGIE ASSISTED BREATHING TUBE PLACEMENT DURING INTUBATION Dalhousie University Senior Design Project Group #7 GROUP MEMBERS: CHRIS CLONEY LAURA HADLEY BRIAN JOSEPH IAN WESTHAVER SUPERVISOR: DR. TED HUBBARD CLIENTS: DR. ANDREW MILNE 1,2, DR. DENNIS DRAPEAU 1 1 DEPARTMENT OF ANESTHESIA – DALHOUSIE UNIVERSITY 2 SCHOOL OF BIOMEDICAL ENGINEERING – DALHOUSIE UNIVERSITY
2
Overview 2 Recap Introducer External magnet Testing Requirements and Recommendations
3
Problem 3
4
4
5
5
6
6
7
Last Semester 7 Bougie, a.k.a. Introducer External Magnet
8
Final Device 8
9
Introducer – Overview 9 Pictures of how the device is made and describing what is coming next Tip selection Design Issues Tip encasement
10
Introducer – Type of Tip 10
11
Introducer – Type of Tip 11
12
Introducer – Type of Tip 12
13
Introducer – Type of Tip 13
14
Introducer – Type of Tip 14 Spherical Magnets Latex Encasing
15
Introducer – Design Issues 15 Pictures of how the device is made and describing what is coming next Flop (Flimsy Tip) Buckling (Force Direction) Tip encasement
16
Introducer – Flop Issue 16 ? Due to Force of Breathing Tube
17
Introducer – Flop Issue 17 ? Due to Force of Breathing Tube
18
Introducer – Flop Issue 18 Seven 5 mm magnets = 35 mm of magnets 55 mm maximum length Leaves 10 – 20 mm plastic
19
Introducer – Buckling Issue 19 Buckling issue occurs when the angle between the trachea and mouth is sharp, and the magnetic tip buckles at the tracheal opening ?
20
Introducer – Buckling Issue 20 ?
21
Introducer – Buckling Issue 21
22
Introducer – Tip Encasement 22 External Magnet brought in
23
Introducer – Tip Encasement 23 ?
24
Introducer – Tip Encasement 24 – Control ? – Too Stiff
25
Introducer – Tip Encasement 25 – Control – Too Stiff Layered Latex Dipping
26
Introducer – Final Design 26
27
External Magnet – Overview 27 Mounting Bracket Pin Handle Magnet Stack Cap
28
External Magnet – Stack Size 28 The size of the magnet stack was chosen through qualitative testing. The final magnet stack was as large as possible but still comfortable for a range of hand sizes.
29
External Magnet - Handle A block of plastic was sized using modeling clay on the intubation mannequin 2”
30
External Magnet - Handle 1 ” Magnets are sized using standard test procedures discussed last term, and a suitable hole is cut
31
External Magnet - Handle Steel mounting bracket is designed to hold magnets, and placed in the new cavity at right
32
External Magnet - Handle Curvature of design intended to give more accurate targeting of trachea, and placement under chin contours
33
External Magnet - Handle Rounded corners for patient and operator safety
34
External Magnet - Handle Holes placed for additional mounting apparatus
35
Testing – Overview 35 Distance Thick Neck Model Time Trials Failure Modes Neck Positioning
36
Testing – Distance 36 External Magnet brought down
37
37 Testing – Distance
38
Testing – Thick Neck Model 38 Thin pieces of rubber representing an obese patient, or a patient with a goiter or tumour.
39
Testing – Time Trials 39 Fourteen completed trials: 12 successful on 1 st attempt 2 successful on 2 nd attempt
40
Testing – Time Trials 40 Fourteen completed trials: 12 successful on 1 st attempt 2 successful on 2 nd attempt
41
Testing – Time Trials Fourteen completed trials: 12 successful on 1 st attempt 2 successful on 2 nd attempt Introducer Only: 8.7 ± 1.4 s (95% CI) Breathing Tube Placement: 21.5 ± 2.0 s (95% CI) 41 **Confidence interval was calculated assuming t-distribution
42
Testing – Neck Contortion 42
43
Destructive Testing – Failure Modes 43 Failure Mode# TrialsForce RequiredDiagram - Notes Tip in tension84.0 ± 1.2 lb (95% CI) One low value of 1.75 lb One ball in tension 33.5 ± 1.5 lb (95% CI) Latex stretched extremely far before rupture Tip in shear314.9 ± 4.0 lb (95% CI) Epoxy crushed but tip did not dislocate **Confidence interval was calculated assuming t-distribution
44
Requirements 44 RequirementResult Medical grade materials Plastics and metal Latex Disposable or easily sterilized Introducer: disposable External Magnet: sterilizable Portable, volume less than 3500 cm 3 Introducer: External Magnet: Light, weigh less than 3 kg Introducer: External Magnet: 1-2 attempts to introduce breathing tube Fourteen Trials 12 of 14 successful on first attempt Less than 25 seconds 8.7 ± 1.4s (introducer only) 21.5 ± 2.0s (total)
45
Recommendations and Unknowns Material change: Nitrile Packaging Cases Contraindications Further testing Cadaver testing Human clinical trial(s) Device inspection, classification and approval 45
46
Anaesthesiologist Using Our Device 46
47
Anaesthesiologist Using Our Device 47 Clients satisfied with level of completion and quality of work Quotations from meetings: “”
48
Questions ? Thank you to: Department of Anaesthesia Dr. Dennis Drapeau Dr. Andrew Milne Department of Mechanical Engineering Dr. Ted Hubbard Peter Jones Shell 48