Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data Quantum Data - Overview.

Similar presentations


Presentation on theme: "Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data Quantum Data - Overview."— Presentation transcript:

1 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data Quantum Data - Overview Mission Statement – Quantum Data invents test instruments that help manufacturers bring next-generation audio, video, and control products to market – faster and without interoperability problems. History – Quantum Data was founded in 1979 by Allen and Ann Jorgensen and has been at the leading edge of programmable video test generator technology since its inception. Over the years, the company has expanded the scope of its products to include other types of video test equipment. – You’ll find Quantum Data instruments in the Authorized Test Centers and design laboratories and production facilities of major consumer electronics and information technology manufacturer’s throughout the world.

2 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort - Overview General – A Video Electronics Standards Association (VESA) Standard. – DisplayPort is a digital display interface standard (approved May 2006, current version 1.1 approved in April of 2007). – Defines a new license-free, royalty-free, state-of-the-art digital audio/video interconnect. – Envisioned to replace both DVI and VGA interface. Applications – Connecting a computer and its display. – Connects PCs, computer monitors, graphic cards. – Can be used for internal display panels. – TV displays. – Projectors.

3 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort - Architecture

4 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort – Aux Channel Operation Aux Channel provides – Device services (Content Protection & EDID) – Device services over I2C emulation Content Protection (HDCP) EDID – Link services (link training) - Negotiates how DisplayPort devices communicate during link training, including: Number of Lanes (1, 2, 4) Lane Rate (1.62Gb/s or 2.7Gb/s) Equalization Levels Aux Channel Operation – AUX CH of DisplayPort is a half-duplex, bi-directional channel – Source device is the master - AUX CH Requester – Sink device is the slave - AUX CH Replier – Source device initiates request transactions – Sink device responds with a reply transaction

5 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort – Two Hot Plug Types IRQ (interrupt request) pulse - 0.5ms to 1ms – Source Device must read the link / sink status field of the DPCD and take corrective action. Hot plug event pulse - longer than 2ms – Source must read the receiver capability field and link / sink status field of the DPCD and take corrective action.

6 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort – Test Requirements Physical layer testing (main link and aux channel) Pattern testing – Timings and test patterns Link layer testing – Compliance and debug tools HDCP testing – Compliance and production Functional testing – Signal analysis, EDID, etc. DDC/CI (MCCS)

7 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data Quantum Data’s DisplayPort Test Solutions Pattern testing – Supports VESA timings up to 268MHz pixel rates (higher pixel rates supported soon). – Over 300 test patterns with the ability to create custom patterns and bitmaps, animated images. Configurability – One (1), 2 & 4 lane configurations with user-specified selection of each to override link training. – Lane rates of 1.62Gb/s & 2.7Gb/s with user-specified selection of each to override link training. – Standard configurability of 880 series Link layer compliance testing, for… – Sources devices. – Sinks devices. – HTML reports provide pass/fail status and test details (coming soon). HDCP testing – Compliance Testing for… Sink devices – approved by VTM (for VESA) as an authorized tool. Source devices (coming soon) and production. – Production Testing for… Sink devices. – HTML reports provide pass/fail status and test details (coming soon). Aux channel sniffer (coming soon) – Logs link layer transactions such as link training – Logs HDCP, EDID & hot plug circuit transactions – Messaging interface supports for real time analysis or post test analysis EDID viewing – On connected display – HTML report

8 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data Pattern Testing of DisplayPort Sinks Timings (formats) - Supports VESA timings up to 268MHz pixel rates (higher pixel rates/resolutions supported soon). – Discrete Mode Timing (DMT) – Coordinated Video Timing (CVT) Test patterns – Over 300 standard static and animated test patterns – ImageShift – animate any static test pattern – Import bitmaps and jpegs – Create custom images with graphics SDK API

9 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data 880 Series DisplayPort Configurations 882E Series configurations supported – DisplayPort Tx card – DisplayPort Tx card with Rx card – (coming soon) DisplayPort Tx card with ACA (aux channel sniffer) (Future) 880 Series possible configurations – DisplayPort Tx card & Rx card & ACA card (aux channel sniffer) – DisplayPort Tx card & Rx card & HDMI Tx

10 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data 880 Series DP Programmability One (1), 2 and 4 lane configurations with user- specified selection of each to override link training. Lane rates of 1.62Gb/s & 2.7Gb/s with user-specified selection of each to override link training. Standard configurability offered by 880 series, including: – Timing parameters such as vsync, hsync, resolution, etc. – Bit depths: 6, 8 & 10 – Sampling modes: 4:4:4 & 4:2:2 – Color component gating – Colorimetry: RGB or YCbCr – Component scaling – ramp up/down color component values throughout entire range

11 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort – Link Layer Testing Link layer compliance testing of sink devices. Runs link layer compliance test (per spec) on sink devices in batch mode or individually through command line. The following tests are performed: 5.2.1.1 Read One Byte from Valid DPCD Address 5.2.1.2 Read Twelve Bytes from Valid DPCD Address 5.2.1.3Write One Byte to Valid DPCD Address 5.2.1.4Write Nine Bytes to Valid DPCD Addresses 5.2.1.5 Write Nine Bytes to Read-Only DPCD Address 5.2.1.6 Write EDID Offset (One Byte I2C-Over-Aux Write) 5.2.1.7 Read One EDID Byte (One Byte I2C-Over-Aux Read) 5.2.1.8 EDID Read (1 Byte I2C-Over-Aux Segment Write, 1 Byte I2C-Over-Aux Offset Write, 128 Byte I2C-Over-Aux Read) 5.2.1.9 Illegal Aux Request Syntax 5.2.2 EDID Read 5.3.1.1 Successful Link Training at All Supported Lane Counts and Link Speeds 5.3.1.2Successful Link Training with Request of Higher Differential Voltage Swing during Clock Recovery Sequence 5.3.1.3 Successful Link Training to a Lower Link Rate Due To Clock Recovery Lock Failure During Clock Recovery Sequence 5.3.1.4 Successful Link Training with Request of a Change to Pre-Emphasis And/Or 5.3.1.5 Successful Link Training at Lower Link Rate Due to Loss of Symbol Lock During Channel 5.3.1.6 Lane Count Reduction 5.3.1.7Lane Count Increase 5.3.2.1 IRQ_HPD Pulse Due to Loss of Symbol Lock and Clock Recovery Lock 5.3.2.2IRQ HPD Pulse Due to Loss of Inter-lane Alignment Lock 5.4.1.1 Pixel data reconstruction 5.4.1.2 Main Stream Data Unpacking and Unstuffing – Least Packed TU 5.4.1.3 Main Stream Data Unpacking and Unstuffing – Most Packed TU 5.4.2 Main Video Stream Format Change Handling

12 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort – Link Layer Testing Link layer compliance testing for source devices. Runs link layer compliance test (per spec) on source devices in batch mode or individually through command line. The following tests are performed: 4.2.1.1 Source DUT Retry on No-Reply During Aux Read after Hot Plug Event 4.2.1.2 Source Retry on Invalid Reply During Aux Read after Hot Plug Event 4.2.2.1 EDID Read upon Hot Plug Event 4.2.2.2 DPCD Receiver Capability Read upon Hot Plug Event 4.2.2.3 EDID Read 4.2.2.4 EDID Absence Detection 4.2.2.5EDID Corruption Detection 4.3.1.1 Successful Link Training Upon Hot Plug detect 4.3.1.2Successful Link Training at All Supported Lane Counts and Link Speeds 4.3.1.3 Successful Link Training with Request of Higher Differential Voltage Swing during Clock Recovery Sequence 4.3.1.4 Successful Link Training to a Lower Link Rate #1: Iterate at Maximum Voltage Swing 4.3.1.5Successful Link Training to a Lower Link Rate #2: Iterate at Minimum Voltage Swing 4.3.1.6 Successful Link Training with Request of a Higher Pre-emphasis Setting During Channel Equalization Sequence 4.3.1.7 Successful Link Training at Lower Link Rate due to Loss of Symbol Lock During Channel Equalization Sequence 4.3.1.8Unsuccessful Link Training at Lower Link Rate #1: Iterate at Maximum Voltage Swing 4.3.1.9 Unsuccessful Link Training at Lower Link Rate #2: Iterate at Minimum Voltage Swing 4.3.1.10 Unsuccessful Link Training due to Failure in Channel Equalization Sequence 4.3.1.11 Lane Count Reduction 4.3.1.12 Lane Count Increase 4.3.2.1 Successful Link Re-training After IRQ HPD Pulse Due to Loss of Symbol Lock 4.3.2.2Successful Link Re-training After IRQ HPD Pulse Due to Loss of Clock Recovery 4.3.2.3Successful Link Re-training After IRQ HPD Pulse Due to Loss of Inter-lane 4.3.2.4No link re-training required after IRQ HPD pulse 4.4.1.1Pixel Data Steering 4.4.1.2Main Stream Data Packing and Stuffing – Least Packed TU 4.4.1.3 Main Stream Data Packing and Stuffing – Most Packed TU 4.4.2 Main Video Stream Format Change Handling

13 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort – HDCP Testing Compliance Testing – Sink devices – approved by VTM (for VESA) as an authorized tool – (coming soon) Source devices Production Test – Sink devices

14 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort – HDCP Testing Sample of HDCP Compliance Test report – Summary Page.

15 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort – HDCP Testing Sample of HDCP Compliance Test report. Details Page

16 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort - Aux Channel Sniffer Logs link layer transactions such as link training Logs device I2S transactions such as HDCP, EDID & hot plug Messaging interface support for real time analysis or post-test analysis

17 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort - Aux Channel Sniffer Link transactions showing Link Training S A M P L E O N L Y

18 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort - Aux Chan Sniffer (HDCP/EDID) Device transactions showing – EDID – HDCP S A M P L E O N L Y

19 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data DisplayPort – EDID Testing EDID viewing/testing – On connected display – HTML report

20 Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data Quantum Data DisplayPort Roadmap Signal analysis for source tesing – Timing measurements – measures resolution (active/blanking) and vertical and horizontal sync rates – Pixel error testing – compares received frames vs reference frame – Image capture – display component values EDID Emulation – EDID Editor support DDC/CI (MCCS) – Command GUI – Message logging through ACA Audio – Audio signal generation


Download ppt "Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data Quantum Data - Overview."

Similar presentations


Ads by Google