Presentation is loading. Please wait.

Presentation is loading. Please wait.

1 FITTING INSTRUCTIONS DUCOSUN UNIFIT Cubic & Linear.

Similar presentations


Presentation on theme: "1 FITTING INSTRUCTIONS DUCOSUN UNIFIT Cubic & Linear."— Presentation transcript:

1 1 FITTING INSTRUCTIONS DUCOSUN UNIFIT Cubic & Linear

2 2 Product DUCOSUN UNIFIT Cubic & Linear

3 3 Parts Breakdown Cubic 150 series louvre blade Code : P15102-10 Linear 200 series louvre blade Code : P11938-10 Cubic 200 series louvre blade Code : P11921-10 Linear 300 series louvre blade Code : P11939-10 Cubic 300 series louvre blade Code : P11922-10 Cubic 100 series louvre blade Code: P15232-10 DUCOSUN UNIFIT Cubic & Linear

4 4 Parts Breakdown Linear 200 type I series R.H. end plate ALU plate 3mm Code : G0002102 (PT081050) Linear 300 type I series R.H. end plate ALU plate 3mm Code : G0002105 (PT081076) Linear 200 type I series L.H. end plate ALU plate 3mm Code : G0002101 (PT081049) Cubic 200 type I series end plate ALU plate 3mm Code : G0002100 (PT081057) Linear 300 type I series L.H. end plate ALU plate 3mm Code : G0002104 (PT081075) Cubic 300 type I series end plate ALU plate 3mm Code : G0002103 (PT081068) DUCOSUN UNIFIT Cubic & Linear

5 5 Parts Breakdown Cubic 150 type I series R.H. end plate ALU plate 3mm Code : G0002210 (PT081050) 0° Unifit for Cubic 150 series louvre blades Code : G000 (T11952-10) End plateCubic 100 Type I ALU plate 3mm Code: G0105050 0° Unifit for Cubic 200 & 300 series louvre blades Code : G0001875 (T11932-10) Unifit 0° forCubic 100 Code: G0105070 45° Unifit for Linear 200 & 300 series louvre blades Code : G0001870 (T11952-10) DUCOSUN UNIFIT Cubic & Linear

6 6 Parts Breakdown Countersunk screw, M5x55 to DIN 7991 Code : G0000216 Self-locking hexagon nut M8 to DIN 985 Code : G0000162 M8x20 T-head bolt Code : G0000150 (PT01003) Self drilling screw hex 6.3x32 stainless steel, to DIN 7504 K Code : G0000300 Flat washer M5 to DIN 125, A2 grade stainless steel Code : G0000176 Countersunk screw 4.8x16 DIN 7504-O Code: G0105040 DUCOSUN UNIFIT Cubic & Linear

7 7 Parts Breakdown M8 washer, to DIN 125-1 A Code : G0000174 M8 washer plate Code : G0000166 (PT030253) M8x20 hexagonal bolt, to DIN 933 Code : G0000215 Self-tapping screw M6x30 to DIN 7500 Code : G0000113 Hex head bolt M8x20, to DIN 933 Code : G0000209 Lock nut M5, to DIN 985 Code : G0000165 DUCOSUN UNIFIT Cubic & Linear

8 8 Parts Breakdown Linear 300 series blades connection set Code : S5000061 Cubic 300 series blades connection set Code : S5000071 Linear 200 series blades connection set Code : S5000060 Cubic 150 series blades connection set Code : S5000072 Cubic 200 series blades connection set Code : S5000070 Cubic 100 series blades connection set Code : S5000069 DUCOSUN UNIFIT Cubic & Linear

9 9 Assembly & Fitting 1. Preparing the support profiles a.Bolt the bottommost L-shaped profile down to the support profiles with M8x80 mm hex head bolts (G0000200) (ensure the bolts will thread all the way through the support profiles), the corresponding washers (G0000174) and lock nuts (G0000162). b.Tighten the other L-shaped profiles down using M8x25 mm T-head bolts (G0000150) and the corresponding washers and lock nuts. DUCOSUN UNIFIT Cubic & Linear

10 10 Assembly & Fitting 2. Securing the support profiles to the wall a. Secure the support profiles to the wall using wall anchors. DUCOSUN UNIFIT Cubic & Linear

11 11 Assembly & Fitting 3. Fitting the UniFit series blade holders to the support profiles a.First, loosely secure the 2 washer-plates (G0000166) to the UniFit series blade holders with 2 M8x20 mm bolts (G0000215) and 4 washers (G0000174). b.Next, slide the bottommost UniFit blade holder (a 45° holder, for example) in the support profiles, ensure that it is properly positioned and tighten the M8x20 mm hex head bolts (G0000215). DUCOSUN UNIFIT Cubic & Linear

12 12 Assembly & Fitting 3. Fitting the UniFit series blade holders to the support profiles c.Next, starting from the top, fit the pre-assembled UniFit series blade holders to the support profiles using washer plates and repeat the previous step for each UniFit series blade holder to be fitted at the centres specified. DUCOSUN UNIFIT Cubic & Linear

13 13 Assembly & Fitting 4. Securing tube sections to the wall a) The tube sections may be replaced with aluminium sections with a MINIMUM wall thickness of 3mm. In this case, the Unifit series blade holders are to be fixed with M6.3x32 mm self drill screws (G0000300) and M5 washers. The tube sections can be fixed to an asymmetric L-shaped profile with M8x80 mm hex head bolts (G0000209) (ensure the bolts go all the way through the support profiles when maximum width is 50 mm), and washers G0000174) and M8 nuts (G0000160). DUCOSUN UNIFIT Cubic & Linear

14 14 5. Securing the UniFit series blade holders to the tube sections UniFit series blade holders can be fixed with 6.3x32 mm self-drilling screws (G0000300) and M6 washers. Start fitting the lowest UniFit series blade holder ; use a gauge to match the centre-to-centre distance between 2 forks. DUCOSUN UNIFIT Cubic & Linear Assembly & Fitting

15 15 Assembly & Fitting 6. Preparing the blades Take the cut to size blades (Linear 200 series blades, for example), fit an end plate at either end and secure them in place with M6x30 mm csk self tapping screws to DIN 7500 M-Z (G0000113) DUCOSUN UNIFIT Cubic & Linear

16 16 Assembly & Fitting 7. Blade fitting Cubic 100 blades are each fixed in position with 2 screws Ø4,8x16 (G0105040) Cubic 200 and Linear 200 series blades are each fixed in position with 2 M4.8x25 mm self-drilling screws (G0000228). Cubic 300 and Linear 300 series blades are secured in position with M5x55 mm countersunk bolts – which pass all the way through the profiles – and with M5 lock nuts. Cubic and Linear 200 series blades Cubic and Linear 300 series blades DUCOSUN UNIFIT Cubic & Linear

17 17 Assembly & Fitting 8. Blade span a.Maximum span between two forks : b.To calculate the strength and stability, please use Duco's calculation program. Mounting with UNIFIT Blade TypeWidthAt Windload of 600Pa800Pa1250Pa UNIFIT (± 115km/h)(± 130km/h)(± 165km/h) Cubic 1000° 40310029002600 Cubic 1500° 403075 Cubic 2000° 403400 Linear 20045° 403400 Cubic 3000° 40390033002200 Linear 30045° 403900 2700 DUCOSUN UNIFIT Cubic & Linear

18 18 Assembly & Fitting 9. Joining of blades I. Cubic & Linear 200 series blades II. Cubic and Linear 300 series blades III Cubic 100 & 150 series blades DUCOSUN UNIFIT Cubic & Linear

19 19 Assembly & Fitting 9. Joining of blades I. Cubic & Linear 200 series blades II. Cubic and Linear 300 series blades III Cubic 100 & 150 series blades DUCOSUN UNIFIT Cubic & Linear

20 20 Assembly & Fitting I. Cubic & Linear 200 series blades a.Insert the locating pin into the first blade first and then fit a type II end plate and secure with self-tapping screws (G0000113). 9. Joining of blades DUCOSUN UNIFIT Cubic & Linear

21 21 Assembly & Fitting b.Insert an adjustable bush Ø 29/75 (G0012000) in the second blade first and then fit a type II end plate and screw it down with self-tapping screws (G0000113). c.Next, gently press the two blades together. CAUTION : Enough clearance should be present to allow the blades to expand. I. Cubic & Linear 200 series blades DUCOSUN UNIFIT Cubic & Linear

22 22 Assembly & Fitting II. Cubic and Linear 300 series blades a.Insert an adjustable bush Ø 29/75 (G0012000) into the right-hand blade first and then fit a type II L.H. end plate and screw it down with four M6x30 mm screws (G0000113) ; start tightening the outer screws, apply anti-seize compound to the threads and use a 12V screwdriver (minimum). (Fig. 3) Fig. 3 Fig. 4 b.Insert a locating pin into the left-hand blade first and then fit a type II L.H. end plate and screw it down with 4 M6x30 mm screws (G0000113) ; start tightening the outer screws, apply anti-seize compound to the threads and use a 12V screwdriver (minimum). (Fig. 4) DUCOSUN UNIFIT Cubic & Linear

23 23 Assembly & Fitting d.Next, gently press the two blades together. CAUTION : Enough clearance should be present to allow the blades to expand. II. Cubic and Linear 300 series blades DUCOSUN UNIFIT Cubic & Linear

24 24 Assembly & Fitting III. Cubic 100 & 150 series blades b. Fit a joint plate to both the left-hand and right hand blades and screw them down with 2 M6x30 mm screws (G0000113) ; start tightening the outer screws, apply anti-seize compound to the threads and use a 12V screwdriver (minimum). (Fig. 3) Fig. 4 a. Secure a fixed fulcrum pin Ø14 (G0001796) to the joint plate (G0002136) with 1 M5x16 mm screw (G0000223) first and then a 14 mm clamping bush MCM-14-03 (G0012010). DUCOSUN UNIFIT Cubic & Linear

25 25 Assembly & Fitting C. Next, gently press the two blades together. CAUTION : Enough clearance should be present to allow the blades to expand. III. Cubic 100 & 150 series blades DUCOSUN UNIFIT Cubic & Linear


Download ppt "1 FITTING INSTRUCTIONS DUCOSUN UNIFIT Cubic & Linear."