Presentation is loading. Please wait.

Presentation is loading. Please wait.

SPRAY-DOWN OVERLAYMENT APPLICATION SPRAY-DOWN. THE BENEFITS OF OVERLAYMENT REPAIR EXISTING SURFACES PROFITABLE ELIMINATE REMOVAL SAVES TIME ON EXISTING.

Similar presentations


Presentation on theme: "SPRAY-DOWN OVERLAYMENT APPLICATION SPRAY-DOWN. THE BENEFITS OF OVERLAYMENT REPAIR EXISTING SURFACES PROFITABLE ELIMINATE REMOVAL SAVES TIME ON EXISTING."— Presentation transcript:

1 SPRAY-DOWN OVERLAYMENT APPLICATION SPRAY-DOWN

2 THE BENEFITS OF OVERLAYMENT REPAIR EXISTING SURFACES PROFITABLE ELIMINATE REMOVAL SAVES TIME ON EXISTING SURFACES TRANSFORMS EXISTING SURFACES TO GIVE THE APPEARANCE OF BRICK, TILE OR STONE

3 SPRAY-DOWNAPPLICATION PREPARE YOUR SURFACEPREPARE YOUR SURFACE PRIME WITH A PRIMERPRIME WITH A PRIMER APPLY YOUR BASE COAT (GRAY OR WHITE)APPLY YOUR BASE COAT (GRAY OR WHITE) TROWEL OR SQUEEGEE YOUR BASE COAT COVERING THE ENTIRE SURFACETROWEL OR SQUEEGEE YOUR BASE COAT COVERING THE ENTIRE SURFACE 60 POUNDS COVERS UP TO 56 SQUARE FEET AT 1/8” THICK60 POUNDS COVERS UP TO 56 SQUARE FEET AT 1/8” THICK

4 ALLOW BASE COAT TO DRY THOROUGHLYALLOW BASE COAT TO DRY THOROUGHLY LAY THE FIRST PIECE OF STENCILLAY THE FIRST PIECE OF STENCIL ALL STENCIL SHOULD BE PLACED “MEMORY-SIDE” DOWNALL STENCIL SHOULD BE PLACED “MEMORY-SIDE” DOWN STENCIL

5 SPRAY ADDITIONAL BASE COAT IN AREAS WHERE THE STENCIL NEEDS TO BE WEIGHTED DOWN FURTHERSPRAY ADDITIONAL BASE COAT IN AREAS WHERE THE STENCIL NEEDS TO BE WEIGHTED DOWN FURTHER REPEAT UNTIL THE ENTIRE STENCIL IS DOWNREPEAT UNTIL THE ENTIRE STENCIL IS DOWN OPTION ONE: STENCIL

6 COLOR COAT/TOP COAT COLORPAX DRY PIGMENT DRY PIGMENT PRE-MEASURED PRE-MEASURED MIXES DIRECTLY INTO OVERLAY MIX MIXES DIRECTLY INTO OVERLAY MIX LIQUID COLOR LIQUID PIGMENTLIQUID PIGMENT MIXES DIRECTLY INTO OVERLAY MIXMIXES DIRECTLY INTO OVERLAY MIX

7 IF BASE COAT IS DRY, RE-APPLY PRIMER WITH PUMP SPRAYERIF BASE COAT IS DRY, RE-APPLY PRIMER WITH PUMP SPRAYER APPLY THE TOP COAT MIXED WITH THE DESIRED COLORANTS (LIQUID COLOR OR COLORPAX)APPLY THE TOP COAT MIXED WITH THE DESIRED COLORANTS (LIQUID COLOR OR COLORPAX) SPRAY THE TOPCOAT TO ACHIEVE THIN, EVEN COVERAGESPRAY THE TOPCOAT TO ACHIEVE THIN, EVEN COVERAGE NO ADDITIONAL TEXTURING IS REQUIREDNO ADDITIONAL TEXTURING IS REQUIRED APPLYING COLOR COAT

8 REMOVE STENCIL AS SOON AS THE OVERLAY CHIPS FREELY FROM THE STENCIL (SAME-DAY)REMOVE STENCIL AS SOON AS THE OVERLAY CHIPS FREELY FROM THE STENCIL (SAME-DAY) USE A WIRE BRUSH TO DETAIL JOINTSUSE A WIRE BRUSH TO DETAIL JOINTS DO NOT LEAVE STENCIL IN OVERNIGHTDO NOT LEAVE STENCIL IN OVERNIGHT PULLING YOUR STENCIL

9 CHIPS MAY BE BLOWN OFF WITH LEAF BLOWERCHIPS MAY BE BLOWN OFF WITH LEAF BLOWER SEAL TO THE OVERLAY MANUFACTURER’S SPECIFICATIONSSEAL TO THE OVERLAY MANUFACTURER’S SPECIFICATIONS CLEAN & SEAL

10 CHIPS MAY BE BLOWN OFF WITH LEAF BLOWERCHIPS MAY BE BLOWN OFF WITH LEAF BLOWER SEAL TO THE OVERLAY MANUFACTURER’S SPECIFICATIONSSEAL TO THE OVERLAY MANUFACTURER’S SPECIFICATIONS CLEAN & SEAL

11 STICKY-BAK™ RECOMMENDED USE PERFORMS BEST ON SMOOTH TROWELED SURFACESPERFORMS BEST ON SMOOTH TROWELED SURFACES AMBIENT TEMPERATURE CONDITIONS BETWEEN 70º-90º FAMBIENT TEMPERATURE CONDITIONS BETWEEN 70º-90º F RECOMMENDED USE WITHIN ONE YEAR OF DATE OF MANUFACTURERECOMMENDED USE WITHIN ONE YEAR OF DATE OF MANUFACTURE AVOID EXPOSURE TO EXTREME TEMPERATURESAVOID EXPOSURE TO EXTREME TEMPERATURES

12 TIPS & TRICKS ALTERNATIVE METHODS FOR ADHERING NON-ADHESIVE STENCIL TO THE SLAB: STAPLINGSTAPLING PLUMBER’S PUTTYPLUMBER’S PUTTY HOLE PUNCH & TAPEHOLE PUNCH & TAPE

13 STAPLING LAY OUT FIRST ROW OF STENCIL “MEMORY SIDE” DOWNLAY OUT FIRST ROW OF STENCIL “MEMORY SIDE” DOWN TRIM TO LENGTH, ALLOWING A FEW EXTRA FEET FOR ADJUSTMENTSTRIM TO LENGTH, ALLOWING A FEW EXTRA FEET FOR ADJUSTMENTS REPEAT UNTIL ENTIRE PATTERN IS LAID OUT AND PRE-TRIMMEDREPEAT UNTIL ENTIRE PATTERN IS LAID OUT AND PRE-TRIMMED ALIGN THE ROWS OF STENCIL AND STAPLE (OR TAPE) THE OVERLAPPING JOINTSALIGN THE ROWS OF STENCIL AND STAPLE (OR TAPE) THE OVERLAPPING JOINTS THE COMBINED WEIGHT OF THE ASSEMBLED STENCIL HELPS KEEP IT FLAT AGAINST THE SLABTHE COMBINED WEIGHT OF THE ASSEMBLED STENCIL HELPS KEEP IT FLAT AGAINST THE SLAB

14 PLUMBER’SPUTTY PLACE A SMALL WAD OF PLUMBER’S PUTTY (NON-RESIDUE, OIL-FREE) ON THE UNDERSIDE OF THE STENCILPLACE A SMALL WAD OF PLUMBER’S PUTTY (NON-RESIDUE, OIL-FREE) ON THE UNDERSIDE OF THE STENCIL REPEAT AT INTERVALS OF 18-24 INCHES, OR AS OFTEN AS NECESSARY TO HOLD YOUR STENCIL FLAT AGAINST THE SLABREPEAT AT INTERVALS OF 18-24 INCHES, OR AS OFTEN AS NECESSARY TO HOLD YOUR STENCIL FLAT AGAINST THE SLAB TEST ON A SMALL SCALE TO ENSURE COMPATIBILITY WITH YOUR PRODUCTSTEST ON A SMALL SCALE TO ENSURE COMPATIBILITY WITH YOUR PRODUCTS

15 HOLE PUNCH & TAPE REQUIRES A LARGE DIAMETER HAND PUNCH (3/8 – 7/16 INCH)REQUIRES A LARGE DIAMETER HAND PUNCH (3/8 – 7/16 INCH) PUNCH HOLES IN THE STENCIL AT INTERVALS OF 18-24 INCHESPUNCH HOLES IN THE STENCIL AT INTERVALS OF 18-24 INCHES PLACE A SMALL STRIP OF TAPE OVER EACH HOLE, SECURING THE STENCIL TO THE SLAB THROUGH THE PUNCHED HOLESPLACE A SMALL STRIP OF TAPE OVER EACH HOLE, SECURING THE STENCIL TO THE SLAB THROUGH THE PUNCHED HOLES DUCT TAPE WORKS WELLDUCT TAPE WORKS WELL

16 TRIAL & ERROR THERE ARE MANY METHODS OF LAYING OUT STENCIL FOR SPRAY-DOWN OVERLAYMENT — FIND THE METHOD WHICH WORKS BEST FOR YOUTHERE ARE MANY METHODS OF LAYING OUT STENCIL FOR SPRAY-DOWN OVERLAYMENT — FIND THE METHOD WHICH WORKS BEST FOR YOU START WITH A SMALL TEST BEFORE COMMITTING TO A PARTICULAR TECHNIQUESTART WITH A SMALL TEST BEFORE COMMITTING TO A PARTICULAR TECHNIQUE VARIATIONS IN HUMIDITY AND TEMPERATURE MAY IMPACT YOUR SUCCESSVARIATIONS IN HUMIDITY AND TEMPERATURE MAY IMPACT YOUR SUCCESS BE AWARE OF THE CONDITIONS WHICH CONTRIBUTE TO BLEED-UNDERBE AWARE OF THE CONDITIONS WHICH CONTRIBUTE TO BLEED-UNDER

17


Download ppt "SPRAY-DOWN OVERLAYMENT APPLICATION SPRAY-DOWN. THE BENEFITS OF OVERLAYMENT REPAIR EXISTING SURFACES PROFITABLE ELIMINATE REMOVAL SAVES TIME ON EXISTING."

Similar presentations


Ads by Google