Presentation is loading. Please wait.

Presentation is loading. Please wait.

The Fumigation Monitor Company Integrated Fumigation Monitoring &Web Based Data Acquisition Methyl Bromide & Alternatives Conference Surabaya, Indonesia.

Similar presentations


Presentation on theme: "The Fumigation Monitor Company Integrated Fumigation Monitoring &Web Based Data Acquisition Methyl Bromide & Alternatives Conference Surabaya, Indonesia."— Presentation transcript:

1 The Fumigation Monitor Company Integrated Fumigation Monitoring &Web Based Data Acquisition Methyl Bromide & Alternatives Conference Surabaya, Indonesia PART 2

2 Sulfuryl Fluoride SO2F2

3 1.Corrects Temperature Differences 2.Compensates for Pressure Changes 3.Gas Specific NO Interference Gases 4.Calibration (14,000+Sensors) 5.NOT EMF Susceptible 6.Consistent Ideal Gas Law PV=nRT

4 当前位置:办公厅 > 新闻发布 > 图片新闻办公厅 新闻发布 图片新闻 宁波局穿山港办事处启用熏蒸气体检测仪 日前,宁波检验检疫局穿山港办事处在宁波口岸启用了性能先进、携带方便的熏蒸气体检测仪。该仪器能够在 较短的时间内准确检测出集装箱内残留的有毒有害熏蒸气体的浓度,有效保障现场检验检疫人员及作业人员的人身 安全。此前,该办事处已经配备了两台性能优良的通道式放射性检测仪,大量高科技检测设备的投入使用必将进一 步提高穿山港区废物原料通检效率。 相关文档:

5 Warehouse SF Fumigation

6 Gas Added

7

8 Methyl Bromide CH3Br

9

10

11 Shanghai CIQ Quarantine Fumigation

12 start timeDurationContainerPosition 温度 reading(g/m3) MB300 0 MB-ContainIRZR-A 11/5/2008 12:0026 hours011031bottom 22 ℃ 4342.855.9 11/5/2008 12:1320 hours23mins022435bottom 22 ℃ 6363.488.3 11/5/2008 13:4027hours40mins011031top 22 ℃ 3434.242.2 11/5/2008 14:3022hours40mins022435top 23 ℃ 5859.087.2 11/5/2008 14:3528hours35mins011031bottom 23 ℃ 4140.956.3 11/5/2008 14:4028hours40mins011031top 23 ℃ 3534.847.2 11/5/2008 14:5023hours022435bottom 23 ℃ 6261.672.6 11/5/2008 15:1010mins228489bottom 23 ℃ 123 124.0147.2 11/5/2008 15:2029hours20mins011031middle 23 ℃ 4140.655.7 11/5/2008 15:3035mins336106bottom 23 ℃ 8583.9109.2 11/5/2008 15:4045mins401681bottom 23 ℃ 8281.3109.4 Shanghai CIQ Quarantine Fumigation 20-30% Error with Thermoconductivity Monitor (NO P&T Correction)

13 12/17/2007MeBr at Lab Temperature - Spectros Test LV1008 Pr.Temp.PPM perAirMeBrPPMg/m3SpectrosDifference mm Hg°Cg/m3ml Calc.CalcIR-g/m3Calc-Instr.% 748.028264.448000202,4949.49.50.10.7% 753.228262.618000404,97518.918.6-0.3-1.8% 748.228264.378000809,90137.537.4-0.1-0.1% 748.028264.44800012014,77855.956.91.01.8% 748.028264.44800016019,60874.174.70.60.7% 749.728263.84800024029,126110.4110.50.10.1% 749.928263.77800032038,462145.8145.0-0.8-0.6% 749.928263.77800042049,881189.1187.4-1.7-0.9% 750.528263.56780050060,241228.6225.5-3.1-1.3% 751.528263.21800060069,767265.1262.1-3.0-1.1% 751.528263.21800070080,460305.7302.5-3.2-1.0% 752.128263.00800080090,909345.7339.3-6.4-1.8% 752.528262.8680001000111,111422.7418.0-4.7-1.1% USDA Test of Methyl Bromide MBContainIR #LV1008 APPROVED

14 MBContainIR is USDA Approved APPROVED

15 Apples from New Zealand to Japan Compliant Quarantine Pre Shipment Certification

16 APPROVED

17 Web Based Fumigation Monitoring & Data Acquisition

18 Web Based Platforms Hardened Enclosure Advanced Infrared Technology (NDIR) Solid State Electronics Modular Components Multiple Sample Positions Web Based Data Acquisition & Management NEMA Fixed Transportble

19 Encrypted, Flexible,Secure Data Transmission

20 Secured, Encrypted Website

21 Threshold Settings for Action Alerts

22 Main Networking Functions FTP-Based File Transfer

23 USA Federal Register 21 CFR Part 11 Calibrated Fumigant Gas Cylinder Spectros Monitors Pressure and Temperature Calibration Verification Onsite and Individual Fumigation Proof of Compliance Encrypted Transfer of Secured Data Like “Bank Transfer” Government Enforcement PROOF Electronic Notebook: Traceable to Compliance

24 AN ENCRYPTED WEB BASED TRANSFER OF FUMIGATION DATA STEP1: Fumigation Collects CxT Secured Data STEP2: Method Defined CxT has Spectros Issues Certificate Pass/Fail TRACEABLE TO CERTIFIED CALIBRATION GAS STEP3: Good Fumigation gets Spectros Notification to Customer/ Government Agency Protected Server (ENCRYPTED) STEP4: Governing Agency Issues THEIR TRACKING # (Unique and No Way to Counterfeit) STEP5: This # Used by Brokers/Forwarders/Shipping Companies USA FEDERAL REGISTER: Electronic Notebook 21CFR Part 11 China CIQ & Chile SAG

25 Poor Fumigation Monitoring & Proof= Increased Pest Resistance!

26 Thank You Dennis Glennon Ph.D. Chief Technology Officer Spectros Instruments, Inc. 17D Airport Road Hopedale, MA USA Office 508.478.1648 Direct 508.579.6301 dglennon@spectrosinstruments.com


Download ppt "The Fumigation Monitor Company Integrated Fumigation Monitoring &Web Based Data Acquisition Methyl Bromide & Alternatives Conference Surabaya, Indonesia."

Similar presentations


Ads by Google