1 General System Configuration
Figure 3.1 Inputs IC-1600 INTELLIGENT CONTROLLER READER INTERFACE (RI-130) Receive Ground Transmit J13 J5 J12 J15 J1 Data + Data - Enable + Enable - J9 S1 S2 J5 J6 Data + Data - Enable + Output Points Input Power Enable - Max distance”2 miles” CardReader Channels Max distance 500’ Power Supply J18 (24VDC) Ground Battery - Battery + 120VAC 60hz 120VAC 60hz General System Configuration Overview

2 RI-130 DIAGRAM Figure 3.2 Lower board Upper board J13 J14 J12 J15 J5
J5 goes to a channel on an IC-1600 or CE-1600 Figure 3.2 Lower board Upper board J13 J14 J12 J15 J5 J6 S1 S2 Data + Data - Enable + Go Output 0 Common Enable - Go Output 0 Normally Open J12 connects to the card reader Not Used Go Output 0 Normally Closed Shunt Output 1 Common off Shunt Output 1 Normally Open 5VDC Shunt Output 1 Normally Closed 15VDC Output 2 Common Output 2 Normally Open Ground Output 2 Normally Closed Led Data1 Data0 off S1 configures the RI-130’s Go and Shunt time for Degraded Mode Input 0 Door open Detect Input 1 Exit Push-Button Input 2 Tamper Detect Input 3 Common ( J14) Input 4 Input 5 S2 configures the RI-130 System code for Degraded Mode Input 6 12vac/12VDC+ Input 7 12vac/12VDC- Input 8 Ground Input 9 Ground Input 10 Not Used Input 11 J6 is the input power to the RI-130 RI-130 DIAGRAM

3 RI-130 DIAGRAM Figure 5.1 The Door Open Detect Monitor Point J13 J14
“Unauthorized Door Open Reporting” in Card Reader definition Door Sequences “Report Only if Held Beyond Shunt Time” “Report As Forced Entry Detect (FED)” In AG “Forced Entry” is reported as Door opens under Monitor Activity In AG “Forced Closed” is reported as Door Closes under Monitor Activity When the Door is opened, without “Access Granted” or an “Unlock Command” -Shunt Relay Energizes -Door may stay open until Shunt Time expires -If the door is still open after the shunt time, the “Door Held Open” is reported under Monitor Nothing is reported in AG. Both relays reset as door closes Nothing is reported in AG. Both relays reset as door closes. When Access is Granted. Door opens, then Door closes before Go Relay Times out. To Door Contact When Access is Granted. Door opens, then Door closes before Shunt Relay Times out. Nothing is reported in AG. Shunt Relay resets as door closes. Nothing is reported in AG. Shunt Relay resets as door closes In AG “Door Held Open” is reported under Monitor Activity In AG “Door closed” is reported after the door closes under Monitor Activity In AG “Door Held Open” is reported under Monitor Activity In AG “Door closed” is reported after the door closes under Monitor Activity Access is Granted. Door opens, then Door closes after Shunt Relay Times out. Common Door Open Detect

4 RI-130 DIAGRAM Figure 5.2 The Door Open Detect Monitor Point J15 J12
“Unauthorized Door Open Reporting” in Card Reader definition Shunt Common & Normally open “Report Only if Held Beyond Shunt Time” “Report As Forced Entry Detect (FED)” Door Sequences J12 In AG“Forced Entry” is reported as Door opens under Monitor Activity In AG “Forced Closed” is reported as Door Closes under Monitor Activity Door is opened, without “Access Granted” or an “Unlock Command” Will not function Access is Granted. Door opens, then Door closes before Go Relay Times out. Nothing is reported in AG. Both relays stay energized for the whole duration or the relays’ respected times. Nothing is reported AG. Both relays stay energized for the whole duration or the relays’ respected times. J14 J13 To Door Contact Door Open Detect Access is Granted. Door opens, then Door closes before Shunt Relay Times out. Nothing is reported AG. Shunt Relay stays energized for the whole duration of the shunt time. Nothing is reported AG. Shunt Relay stays energized for the whole duration of the shunt time. In AG “Door Held Open” is reported under Monitor Activity In AG “Door closed” is reported after the door closes under Monitor Activity Access is Granted. Door opens, then Door closes after Shunt Relay Times out. Will Not Function


Download ppt "General System Configuration"