1

2 PROPOSED BURNTHROUGH TEST METHOD CALIBRATION GUIDELINES

3 Objective of Testing: Establish Similar Calibration Procedure Produce Similar Exposure From Burner Achieve Similar Test Results

4 Factors That Can Influence Calibration Air Intake Velocity Air Intake Temperature Fuel Flowrate Fuel Temperature Instrumentation (type/size of thermocouple, calorimeter type) Other Adjustments (position of igniters, static disc, tabs) Fuel Type (Jet A, Diesel, Fuel Oil) Environmental Conditions (relative humidity, barometric pressure)

5 Individual Calibration Rigs

6

7 Protective Heat Shield for Burner Components

8

9 Conditioned Intake Air

10

11 Intake Airbox

12 Intake Airbox Mounted to Burner

13 Fuel Temperature

14 Intake Airbox Holding Air Velocity Meter

15 Measurement of Intake Air and Fuel Temperature

16 Temperature Rake Using 1/8” Closed Bead Thermocouples

17 Factory Mounted Static Disc

18 Static Disc Mounted to Igniter Assembly

19 Temperature Profile Bias

20

21

22 Use of Deflection Tabs at Draft Tube End

23 Air Velocity = 2000 ft/min Igniters @ 6:00 Average Temp = 1912 o F Result: Low on ends, too hot in middle Air Velocity = 2000 ft/min Igniters @ 6:00 Average Temp = 1927 o F Result: Too hot in middle Air Velocity = 2000 ft/min Igniters @ 6:00 Average Temp = 1890 o F Result: Low on ends, too hot in middle Effect of Tab Positioning on Temperature

24 Air Velocity = 2000 ft/min Igniters @ 6:00 Average Temp = 1957 o F Result: Low on ends, too hot in middle Air Velocity = 1900 ft/min Igniters @ 6:00 Average Temp = 1951 o F Result: Low on ends, too hot in middle Air Velocity = 2000 ft/min Igniters @ 9:00 Average Temp = 1860 o F Result: All temperatures in range Effect of Tab Positioning on Temperature

25 Location of Flame Enhancement Tab

26 Air Velocity = 1900 ft/min Igniters @ 9:00 Average Temp = 1846 o F Result: All temperatures in range Air Velocity = 2000 ft/min Igniters @ 9:00 Average Temp = 1860 o F Result: All temperatures in range Air Velocity = 2100 ft/min Igniters @ 9:00 Average Temp = 1882 o F Result: All temperatures in range Air Velocity = 2200 ft/min Igniters @ 9:00 Average Temp = 1896 o F Result: All temperatures in range Day 1 Temperature Calibration @ Various Air Velocity Settings

27 Air Velocity = 2000 ft/min Igniters @ 9:00 Average Temp = 1826 o F Result: All temperatures in range Air Velocity = 2100 ft/min Igniters @ 9:00 Average Temp = 1832 o F Result: All temperatures in range Air Velocity = 2200 ft/min Igniters @ 9:00 Average Temp = 1864 o F Result: All temperatures in range Day 2 Temperature Calibration @ Various Air Velocity Settings

28 Air Velocity = 1900 ft/min Igniters @ 9:00 Average Temp = 1863 o F Result: All temperatures in range Air Velocity = 2000 ft/min Igniters @ 9:00 Average Temp = 1887 o F Result: All temperatures in range Air Velocity = 2100 ft/min Igniters @ 9:00 Average Temp = 1913 o F Result: Middle temperatures slightly high Day 3 Temperature Calibration @ Various Air Velocity Settings

29

30 Day 1 Heat Flux Calibration @ Various Air Velocity Settings Date: 11/17/99

31 Day 2 Heat Flux Calibration @ Various Air Velocity Settings Date: 11/18/99

32 Day 3 Heat Flux Calibration @ Various Air Velocity Settings Date: 11/19/99

33

34 Date: 11/23/99

35 Date: 11/24/99

36 Latest Calibration Procedure Temperature: (1850 o F +/- 100 o F) Adjust Fuel Flowrate to 6.0 gal/hr Adjust Burner Intake Air Velocity to 2200 ft/min Heat Flux: (15.2 Btu/ft 2 sec +/- 0.8 Btu/ft 2 sec) After 2-minute warm-up, swing burner into position, allow 1 minute stabilization, take reading for 30 seconds (once per second) and average, swing burner away from flame After 2-minute warm-up, swing burner into position, allow 1 minute stabilization, take reading for 30 seconds (once per second) and average, swing burner away from flame

37 Calibration Tests Using Aluminum Skin

38 Round Robin Burnthrough Testing Material Selection Quick-Failing Material (< 1 minute) Long Duration Passing Material (> 5 minutes) 1-2 Minute Material Combination 2-3 Minute Material Combination

39 Round Robin Burnthrough Testing Purpose To identify problems encountered during calibration of test equipment to ensure similarity between labs To prove similarity of test equipment through testing of identical samples Cataloguing Method for Identifying Materials Ins Thickness (in) - Ins Density (lb/ft 3 ) - Ins Type - Add Barrier - Film - Weight Class (Thickness) 60=0.60 42=0.42 34=0.34 FG=Fiberglass OPF=Oxidized Polyacrylonitrile Fiber PAN=Polyacrylonitrile Fiber RPI=Rigid Polyimide Foam NEX=Nextel Ceramic Paper FOP=Felted OPF NQZ=Needled Quartz CFS=Carbon Fiber Skrim PET1=class 1 polyethylene terepthalate PVF2=class 2 polyvinyl fluoride PI=polyimide FC=fluoropolymer composite Example: 2-42-FG-NEX-PET-1

40 Burnthrough Round Robin Test Results (Imaginary)

41 Burnthrough Test Method Round Robin Task Group Test Facilities Material Suppliers FAATC - Tim Marker CEAT - Anne Mansuet Darchem Flare - Darren Dodd CTA - Anna Villate Boeing - Hank Lutz Daimler Chrysler - Bernd Menken Johns Manville - Becky Wulliman 3M - Tom Tompkins Mexmil - Dave Indyke Accufleet - Jim Davis Akro Fireguard - George Danker International Aero - John Brooks No Fire - Sam Gottfried Orcon - Sherm Smith 3M - Tom Tompkins Johns Manville - Becky Wulliman Mexmil - Dave Indyke Osaka Gas - Yo Ishikawa Inspec Foams - Dan Trahan Schneller - Dale Onderak Facile - Paul Harencak Lamart - Dave Shields Jeheir - Jacques Maillard

42