TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD.

Similar presentations


Presentation on theme: "TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD."— Presentation transcript:

1 TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD WORK INSTRUCTION Trained and capable of performing this work: Date: Supervisor or engineer giving Approving to perform: Operator 2 Operator 5 Operator 6 Operator 4 Operator 1 Operator 3 On this page is information about operators that are trained and certified to perform this Standard Work. The operators signing below have read this SWI and have successfully performed the work described in it in the presence of the Supervisor or Engineer signing in the second column on the date in the third column.

2 TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD WORK INSTRUCTION Safety Requirements:Safety glasses In Process Check 1) 2) 3) 4) 5) Inductance and resistance testing station Operator Maintenance 1) 2) 3) 4) 5) Material / Components 1) 2) 3) 4) 5) Tools & Fixtures 1) Resistance meter (Harris Instruments, 5012-05) 2) Inductance meter (Sencore, LC53) 3) Inductance Meter Resistance Meter Inductance Test Fixture Resistance Test Fixture

3 TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD WORK INSTRUCTION Safety Requirements:Safety glasses In Process Check 1) Verify that wire insulation is not in connection. 2) 3) 4) 5) Operator Maintenance 1) 2) 3) 4) 5) Material / Components 1) Stator winding assembly 2) 3) 4) 5) Tools & Fixtures 1) Inductance test fixture 2) Inductance meter 3) 4) 5) 2. R-S Set the phase selector on test fixture to R-S. 1. Connect test fixture to meter 3. R S T Connect red wire to R, white to S and black or blue to T.

4 TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD WORK INSTRUCTION Safety Requirements:Safety glasses In Process Check 1) 2) 3) 4) 5) Operator Maintenance 1) Verify inductance meter calibration is current. 2) 3) 4) Material / Components 1) Print 2) 3) 4) 5) Tools & Fixtures 1) 2) 3) 4) 5) 4. Turn ON the inductance meter and set the correct range. 5. Compare the value measured on the inductance meter to range on print sheet. If not within range, notify Supervisor. 6. R-T Change the phase selector to R-T setting.

5 TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD WORK INSTRUCTION Safety Requirements:Safety glasses In Process Check 1) 2) 3) 4) 5) Operator Maintenance 1) 2) 3) 4) 5) Material / Components 1) 2) 3) 4) 5) Tools & Fixtures 1) 2) 3) 4) 5) 8. S-T Change the phase selector to the S-T setting. 7. Compare the value measured on the inductance meter to range on print sheet. If not within range, notify Supervisor. 9. Compare the value measured on the inductance meter to range on print sheet. If not within range, notify Supervisor.

6 TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD WORK INSTRUCTION Safety Requirements:Safety glasses In Process Check 1) Make sure the wire insulation in not within the connection 2) 3) 4) 5) Operator Maintenance 1) Verify resistance meters calibration is current. 2) 3) 4) Material / Components 1) 2) 3) 4) 5) Tools & Fixtures 1)Resistance meter 2)Resistance test fixture 3) 4) 5) 10. Plug the connectors from the resistance test fixture into the resistance meter. 12. R, S T Connect red wire to R, white to S and black or blue to T. 11. R-S Set the phase selector on test fixture to R-S.

7 TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD WORK INSTRUCTION Safety Requirements:Safety glasses In Process Check 1) 2) 3) 4) 5) Operator Maintenance 1) 2) 3) 4) 5) Material / Components 1) 2) 3) 4) 5) Tools & Fixtures 1) 2) 3) 4) 5) 14. Compare the value measured on the resistance meter to range on print sheet. If not within range, notify Supervisor. 13. Turn ON the resistance meter and set the correct range. 15. R-T Change the phase selector to R-T setting.

8 TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD WORK INSTRUCTION Safety Requirements:Safety glasses In Process Check 1) 2) 3) 4) 5) Operator Maintenance 1) 2) 3) 4) 5) Material / Components 1) 2) 3) 4) 5) Tools & Fixtures 1) 2) 3) 4) 5) 16. Compare the value measured on the resistance meter to range on print sheet. If not within range, notify Supervisor. 18. Compare the value measured on the resistance meter to range on print sheet. If not within range, notify Supervisor. 17. S-T Change the phase selector to the S-T setting.

9 TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD WORK INSTRUCTION Safety Requirements:Safety glasses In Process Check 1) 2) 3) 4) 5) Operator Maintenance 1) 2) 3) 4) 5) Material / Components 1) 2) 3) 4) 5) Tools & Fixtures 1) 2) 3) 4) 5) 20. Turn off the resistance and inductance meters. 19. Disconnect the stator from the test fixture. 21. Coil the wires of stator.

10 TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD WORK INSTRUCTION Signatures of Authorization Production:Manufacturing:Quality:Design:Other: Revision:Date:Reason for Change:Editor: A10/30/2006New SWI Introduction.Tony Dick


Download ppt "TITLE: Resistance and Inductance Testing SWI:REVISION:DATE:PAGES:WORK STATION: Resistance-InductanceA1/1/2014# OF 103015 Technology in Motion STANDARD."