1 WITCH: Status & Outlook
A. Lindroth, M. Beck, B. Delaure, V. Golovko, V. Kozlov, I. Kraev, T. Phalet, N. Severijns, S. Versyck USE the Löpsedelsmetoden, utgå från en egen fråga per minut föredrag: Exactly what will he talk about? Which are the possible choices? Which choices have they made? Why? What will their capacity be with these choices? How are they limited?

2 Contents Brief reminder/introduction to WITCH Recent developments
The next 12 months Ideas for long-term improvements Tell them rapidly what the contents is of each of these points

3 Brief reminder/introduction to WITCH: Motivation
Other physics possible: EC/b+ F/GT e- shake-off And more ...

4 Brief reminder/introduction to WITCH: The Set-up

5 Recent developments: Trap structure!

6 Recent developments: Vertical Beamline

7 Recent developments: MCP & Ion Source Tests

8 Recent developments: Crane

9 Recent developments: other
Control System:basic version almost ready – see other presentation Cabling Web readout: not quite done yet Organization in racks spectrometer electrodes & top chamber designed electronic magnet-system readout/control

10 The next 12 months Top chamber & electrode structure
Trapping tests: ion source and stable rextrap bunches Some sort of recoil spectrum Optimization Simulations/preparations for long-term improvements Tendering of electrode structure is going on via cern now Fill gaps/expand Ctrl Sys (due to rapid development)

11 Ideas for future improvements: Cryogenic Traps
Biggest contribution to response function width: thermal motion in traps! We’ll be looking carefully at SHIPTRAP!

12 Ideas for future improvements: A Tape Station used in a new way
Since recoil nuclei are counted directly in an MCP, that detector will be contaminated  only decays leading to stable daughters can be studied. Solution: tape station for secondary e-creation WE SOMETIMES SAY IN THE WITCH GROUP THAT WE ARE TAKING THE STEP TO A GENERAL RECOIL SPECTROMETER. In the present version that is not true. We also think of doing some developments to allow TOF measurements of spectra x kV ion e- mcp Tape station

13 Summary Several developments have been finished recently, and few remain as we approach a period of systematic tests WITCH will be doing systematic trapping tests, and possibly get some sort of recoil spectrum this radioactive-beam period 2004 will show the principle with decent precision, the set-up and method will be refined and potentially present limits on ”a” will be reached After 2004, or so, larger upgrades of WITCH might be started