Presentation is loading. Please wait.

Presentation is loading. Please wait.

Continuous Carbon and NHy Measurements

Similar presentations


Presentation on theme: "Continuous Carbon and NHy Measurements"— Presentation transcript:

1 Continuous Carbon and NHy Measurements
Eric S. Edgerton, ARA, Inc. EMEP PM Measurement and Modeling Workshop New Orleans, LA, USA 4/20-23/04 EMEP

2 Outline Continuous Carbon Continuous NHy (NH3)
R&P 5400 (SEARCH) Aethelometer (SEARCH) Sunset Labs Particulate Carbon Analyzer (Turner, Robinson) Continuous NHy (NH3) An idea for constraining secondary OC EMEP

3 5400 Schematic EMEP

4 5400 Principle of Operation
Collect particles in metal impactor (0.12 µM Dp50) for 60 minutes, or longer Measure ambient CO2 in analytical loop Heat impactor in 1-4 temperature plateaus, volatilize carbon (final T C) Heat afterburner to 750C, complete combustion to CO2 Quantify ΔCO2 via NDIR (Li-Cor) Repeat (w/o collection step) for artifact (residual) correction Note: For a 1-hour sample, the system produces 19 ppm of CO2 per ug-C/m3 EMEP

5 5400 Precision Jefferson Street – July 2001
TC (ug/m3) EMEP

6 5400i TC vs. TOR TC Jefferson Street, GA - 2001
SEARCH 5400i tends to under predict in winter, but over predict in summer EMEP

7 5400f TC vs. TOR TC Jefferson Street, GA – 2003/4
EMEP

8 Aethelometer Operation
Collect particles on quartz filter tape at controlled flow Monitor absorbance continuously with reference ands sensor beam Advance tape at pre-set time interval or preset absorbance Wavelength-specific conversion to BC (1-minute + time resolution) Nafion drier (SEARCH sites) Activated carbon monolith EMEP

9 Comparison of AETH-BC and TOR-EC at Jefferson Street (Atlanta), GA
We see a consistent relationship across SEARCH sites, with regression slopes between 0.5 and 0.7 EMEP

10 Time Series of 1-minute AETH-BC Jefferson Street (Atlanta), GA (nafion drier and carbon monolith)
Dislocations observed virtually always at virtually all SEARCH sites, noise is instrument specific EMEP

11 Sunset Labs Carbon Analyzer
slide courtesy of Jay Turner, STLU EMEP

12 Sunset Labs Temperature Program
slide courtesy of Jay Turner, STLU EMEP

13 EMEP

14 Pittsburgh Air Quality Study: Carbonaceous Aerosol Samplers
CMU Denuder Sunset in situ Denuder PM2.5 Sunset in-situ OC/EC Analyzer Teflon All Quartz filters analyzed using Sunset Instruments and NIOSH protocol Denuder PM2.5 Quartz CIF Denuder Dynamic Blank Sample PM2.5 Quartz CIF Schematic of different samplers. Definitions of OC & EC shown are the values used in subsequent slides. Rutgers & Carnegie Mellon OC = Sample (Q+CIF) – Dynamic Blank (Q+CIF) EC = Sample Q – Dynamic Blank Q Source: Allen Robinson, Carnegie Mellon University; Barb Turpin Rutgers University EMEP

15 Comparison of Sunset Labs In Situ with Integrated Samples
Excellent agreement except for EC. Note that good agreement with CMU denuder sampler indicates that negative artifact from a denuded in situ not a problem presumably because of short sampling time of in situ? Problems with EC due to refractory build up on in situ filter. This causes premature evolution of EC and biases in split. We changed in situ filter a lot (every few days) during Pittsburgh Supersite. Paper in preparation on this issue. Source: Allen Robinson, Carnegie Mellon University; Barb Turpin Rutgers University EMEP

16 Emissions from Biomass Burning
HMS Fire and Smoke Summary for /21/03 Oak Grove EMEP

17 CO and NOy at Oak Grove – 10/21/03
EMEP

18 Comparison of ERs with Literature Values
FUEL NOy (as NO) SO2 PM2.5 TC BC Savannah/Grassland 60 5.4 83 57 3.1 Trop. Forest 15 5.5 88 64 6.4 non-Trop. Forest 28 9 121 78 5.2 Biofuels 27 3.5 92 51 7.6 Ag. Residues 4.3 42 36 7.5 This Study (Fires) 28+/-14 5.0 +/-2/7 195 +/- 54 63 +/- 14 10 +/- 6.1 This Study (Urban)# 147 +/-10 n.d. 33 +/- 8 9.6 +/- 2.1 Andreae and Merlet. Global Geochem Cyclec 15(4): (A&M) # Based on Jefferson Street, Atlanta, GA SEARCH data ER (g/kg CO) EMEP

19 Continuous Measurements of NHy in SEARCH
EMEP

20 SEARCH NH3 and %NHy 4th Quarter 2003
rural- agricultural urban-industrial % NHy urban-res./ind. urban- residential urban- residential NH3 (ppb) % NHy rural- forested rural- forested suburban 0.32 +/- 0.12 0.49 +/- 0.22 2.54 +/- 2.27 EMEP

21 Total Reduced Nitrogen (NHy) Diagram
Hot Pt converts NHy to NO. Hot Mo converts NOy to NO, but is blind to NHy. SEARCH EMEP

22 NO3/NH4 Diagram SEARCH

23 Continuous NH3 vs Denuder NH3 24 Hour Samples
Gaseous NH3 is deduced by subtracting particulate NH4 from NHy SEARCH EMEP

24 Hourly NH3 and particulate-NH4+ Yorkville, GA – November 2003
EMEP

25 Continuous NH3 vs. Wind Direction Yorkville, GA – November 2003
EMEP

26 1.8 km 2.3 km 4.5 km The Smoking Chicken EMEP

27 Continuous NH4+ and NO3- vs
Continuous NH4+ and NO3- vs. Wind Direction Yorkville, GA - November 2003 Wind Direction EMEP

28 WS and WD Yorkville, GA 11/6-8/01
Transport from Atlanta Low Wind Speed EMEP

29 Particulate NO3- and NH4+ Yorkville, 11/6-8/01
EMEP

30 An Idea for Constraining Secondary OC
Primary Secondary Modern OC OC Fossil OC EMEP

31 Simplified OC Source Matrix
Primary Secondary Total Modern Speciation/CMB S peciation , Models, D ifference 14C Fossil Difference Combination of CMB and C-14 data allows calculation of secondary OC by difference. EMEP

32 OC Source Matrix Atlanta, GA – January
Primary * Secondary Total # Modern 64 +/- 15 <5 61 +/ - 5 Fossil 36 39 * 2000 Data: Zheng et al., ES&T, 2002. # from 14Cdata EMEP

33 OC Source Matrix Atlanta, GA – July 2001
Primary* Secondary Total # Modern <5 +/- 10 >50 59 +/ - 6 Fossil 40 * +/- 18 41 * Zheng et al. Source Apportionment of Fine Particles at Atlanta, GA, AAAR 2002 # from 14C data EMEP

34 Summary For TC, R&P 5400f (with modifications) can reproduce filter-based measurements(+/- 15%), but maintenance (data capture) can be problematic. Log cell pressure. For BC, aethelometer provides reliable, high time resolution information, but AETH-BC = 0.6(+/- 0.1) TOR-TC. Dislocations and high resolution noise are annoyances that require further investigation. Log fast data. For OC, TC and possibly EC, early results from Sunset Labs analyzer are promising. Longer term experience necessary. Continuous carbon and NHy data provide valuable insights into sources, processes, etc.


Download ppt "Continuous Carbon and NHy Measurements"