1 Energy Meters ME

2 Aims You need to keep control of your power consumption,
to follow the power consumption by sector, unit, workshop, to better manage your electrical installation and optimize your building energy efficiency Schneider Electric has designed the ME for the sub-metering of active energy (rms) consumed by a single phase or three phases electric circuit.

3 Scope of application Commercial & Industry
shops in shopping centers, airports, railway stations, hospitals … Shared spaces, offices, workshops, machines Energy Efficiency (new rules to save energy in some countries) Exhibitions Trade and fun fairs, camping sites, mobil-homes, caravans, bungalows, weekly street market, marinas, quaysides. energy generation: windmills, solar energy, photo-voltaics, fuel … Commentaires :

4 Scope of application Residential & small Commercial ME1zr (1P+N)
apartments, houses, Seasonal rentals, bed and breakfast, Camping sites: mobil-homes, caravans, bungalows Commentaires : ME1zr (1P+N)

5 ME Kilowatt hour meters: a complete range
Direct three-phase+neutral ME4 63A Direct three-phase ME3 63A Direct single-phase ME1 63A Class 1 40 to 6000A Through CT’s three-phase+neutral or three-phase ME4zrt

6 ME Energy Meters The ME kilowatt hour meters:
comply with the IEC standard are available in 8 versions, according to their options: Single-phase 3-phases 3-phases + N Global Meter ME ME ME4 + Partial meter ( with reset: zero ) ME1z + Remote ( remote transfer ) ME1zr ME3zr ME4zr Partial meter + Remote + CT ME4zrt ( zrt ) DIRECT 63 A Via CT

7 Improvements on the last version
Class 1 Lead sealing accessory (for direct measurement versions) Complies with new standards: IEC & IEC (accuracy) Marking improvement Icons rather than text when possible rather than Imp Rather than Pulse Clarification: Imax: 63A Ib: 10A rather than 10(63)A Adding of the consumption in VA Individual date – code Note about the individual calibration and tester reference Instruction leaflet improvement More languages: 16 More technical data’s: ex I start Explanation about the flashing meter indicator utilization Explanation about error messages

8 Direct single-phase ME
spare room for the comb Pulse output for Remote transfer ( r ) flashing meter indicator Total or partial meter display 5-digits + decimal point 2-module width Push-button: total or partial meter display. Partial meter reset ( z ) Lead sealing accessory voltage and current inputs 230 V AC, direct 63A, 50/60Hz no power supply

9 Direct three-phase ME3 (without Neutral)
Pulse output for Remote transfer ( r ) flashing meter indicator 4-module width Total or partial meter display 5-digits + decimal point Push-button: total or partial meter display. Partial meter reset ( z ) Lead sealing accessory Voltage and current inputs - 3X230 V AC, 3X400 V AC direct 63 A, 50 and 60 Hz no Power supply

10 Direct three-phase ME4 (with Neutral)
Pulse output for Remote transfer ( r ) flashing meter indicator Total or partial meter display 5-digits + decimal point 4-module width Push-button: total or partial meter display. Partial meter reset ( z ) Lead sealing accessory voltage and current inputs - 3X230/400 V AC direct 63 A, 50 and 60 Hz no Power supply

11 Three-phase ME4zrt with CT
pulsing contact ( r ) Voltage inputs N, L1, L2, L3 3X230/400, 3X230, 3X400 V AC 50 and 60 Hz flashing LED : counting witness 4-module width 5-digit LCD display + decimal point total or partial read out partial meter reset ( z ) Current inputs L1, L2, L3 via CT 40 to 6000 A

12 Marking on the side Eco design (see the certificate)
Individual calibration Designed by Schneider Electric Tester reference C36 Date – code for traceability Manufactured and calibrated in a Schneider plant in Grenoble for a better quality monitoring

13 ME: Advantages Compactness
Complies with new standards: IEC & IEC (accuracy) Direct measurement up to 63 A No CT’s No auxiliary Power Supply Cabling and wiring saving True RMS Metering Accuracy unchanged in unbalanced mains supply Stores the data in EEPROM in the event of a main failure Measurement via CT from 40 to 6000 A Partial meter with resetting Remote transfer output Single-phase products are compatible with the comb Manufacturing in France in a Schneider plant

14 Application example 1: Check metering solution
Master PLC Slave remote I/O Vijeo Look Scada system Schneider Electric New Zealand propose a simple and attractive solution using a Telemecanique Twido PLC and a Merlin Gerin DIN mounted Pulsed Kwh meter with ME counters.

15 Application example 2: Grocery stores & supermarkets
sub-metering, load distribution ME4zrt ME3zr ME1zr Heating Commentaires : Lighting Furnaces Refrigeration

16 Annex: IEC Standards for Meters
61036 Past Now Energy meters Energy Sub-meters ME EMC safety Active Energy The ME is fully compatible with the and with the accuracy part of the