Presentation is loading. Please wait.

Presentation is loading. Please wait.

Volume 109, Issue 12, Pages (December 2015)

Similar presentations


Presentation on theme: "Volume 109, Issue 12, Pages (December 2015)"— Presentation transcript:

1 Volume 109, Issue 12, Pages 2501-2510 (December 2015)
The Impact of Collagen Fibril Polarity on Second Harmonic Generation Microscopy  Charles-André Couture, Stéphane Bancelin, Jarno Van der Kolk, Konstantin Popov, Maxime Rivard, Katherine Légaré, Gabrielle Martel, Hélène Richard, Cameron Brown, Sheila Laverty, Lora Ramunno, François Légaré  Biophysical Journal  Volume 109, Issue 12, Pages (December 2015) DOI: /j.bpj Copyright © 2015 Biophysical Society Terms and Conditions

2 Figure 1 (a) Femoral trochleas from 1-day-old foals. The rectangle represents the region of interest (ROI) assessed. (b) A 4 μm thick section cut from the same region perpendicular to the articular surface, stained with picrosirius red, and imaged with polarized light microscopy to reveal the collagen structure of the articular epiphyseal growth cartilage overlying the subchondral bone in the lower part of the image. Scale bar: 2 mm. The nonvascular articular cartilage has a lamellar appearance at the surface (white asterisk). The vascularized epiphyseal growth cartilage of the epiphysis (dotted line), lies between the growth cartilage and ossification front. The rectangle represents the ROI imaged with SHG. (c) SHG image of central area of an unstained 10 μm thick cartilage slice in the central area of epiphyseal growth cartilage. Scale bar: 100 μm. To see this figure in color, go online. Biophysical Journal  , DOI: ( /j.bpj ) Copyright © 2015 Biophysical Society Terms and Conditions

3 Figure 2 (a) Experimental setup used for SHG and I-SHG (∗) microscopy. The delay control is achieved through two calcite prisms placed between two half-waveplates at 810 nm and full-waveplates at 405 nm so that the fundamental beam exhibits a retardation compared with the reference SHG beam. The black arrow indicates the optical axis. (b) Interferometric pattern obtained from the calibration of the glass plate, using a Y-cut quartz plate as the sample. This is used to link the glass plate angle to the reference phase. The blue line is the fit on the theoretical pattern described in Stolle et al. (45), modulated by a Gaussian envelope in red. To see this figure in color, go online. Biophysical Journal  , DOI: ( /j.bpj ) Copyright © 2015 Biophysical Society Terms and Conditions

4 Figure 3 (a) SHG image and (b) I-SHG image of cartilage (images are graduated in microns). The blue rectangle indicates the ROI used in Fig. 4. Pixels with SHG intensity below 50 counts are displayed in yellow in the I-SHG image. To see this figure in color, go online. Biophysical Journal  , DOI: ( /j.bpj ) Copyright © 2015 Biophysical Society Terms and Conditions

5 Figure 4 (a) SHG image and (b) I-SHG image of cartilage (blue rectangle of Fig. 3). Pixels with SHG intensity lower than 50 counts are displayed in yellow. (c–f) The histograms of Φexp in the rectangles in (a) and (b). The lines over the data are Gaussian fits. The histogram (c) (calculated over 2400 pixels) has two phase peaks at −0.67π with σ = π/4 ± π/50 and at 0.34π with σ = π/3 ± π/50. The green histogram in (d) (calculated over 1500 pixels) has only one peak at 0.22π with σ = π/14 ± π/600. The blue histogram in (e) (calculated over 500 pixels) has two peaks at −0.83π with σ = π/9 ± π/150 and at 0.24π with σ = π/6 ± π/120. The red histogram in (f) (calculated over 1500 pixels) has only one peak at −0.76π with σ = π/16 ± π/1000. To see this figure in color, go online. Biophysical Journal  , DOI: ( /j.bpj ) Copyright © 2015 Biophysical Society Terms and Conditions

6 Figure 5 (a) SHG image of cartilage. (b) Polar plot of the SHG intensity as a function of the incident polarization. The black circles correspond to the experimental measurements obtained from ψ = 45° to ψ = 285°, and the red line shows the extension of these measurements on a full 0° to 360° range. The blue arrows indicate the maximum (Ipar) and minimum (Iperp) intensity used to compute the anisotropy parameter r. (c and d) Bar plots of respectively the mean anisotropy and the mean SHG intensity for polarization parallel to the collagen fibrils over the pixels in the corresponding rectangles in (a). The error bars indicate the standard deviations calculated over all the pixels (respectively 420, 256, 648, and 2601 pixels) in the ROIs. Statistical significance was tested using nonparametric Wilcoxon-Mann-Whitney (NS, no significant difference, ∗p < 0.05, ∗∗p < 0.01). To see this figure in color, go online. Biophysical Journal  , DOI: ( /j.bpj ) Copyright © 2015 Biophysical Society Terms and Conditions

7 Figure 6 (a) f ratio as a function of the standard deviation of the phase distribution. The black dots are obtained by numerical simulations, the black line is a spline, and the colored rectangles represent the calculated f ratios corresponding to the same-colored regions in Fig. 4. (b) Normalized value of the mean SHG intensity in function of the f ratio. The black dots are the results from the numerical simulations (average over 1000 random samples) and the colored rectangles are the experimental <Ipar>, corresponding, respectively, to the same-colored rectangles in Fig. 4. Error bars indicate the standard deviations. Here the x-value of (a) (σ) and the y-value of (b) (SHG intensity) are measured parameters whereas the f ratio is calculated numerically. The similarity between experimental and calculated data was evaluated with Pearson’s chi-squared test (p < −16) using R software (R Development Core Team, R Foundation for Statistical Computing, version 3.0.3). To see this figure in color, go online. Biophysical Journal  , DOI: ( /j.bpj ) Copyright © 2015 Biophysical Society Terms and Conditions

8 Figure 7 (a) HSV image merging Fig. 3, a and b, in which the SHG intensity and phase are represented respectively by the value and the hue of the color. Red arrows indicate regions similar to the blue ROI in Fig. 4 a with a phase transition corresponding to a low SHG intensity. Scale bar: 100 μm. (b) Image merging the SHG intensity (red) and the map of anisotropy parameter r (green). White arrows highlight regions of high anisotropy but low SHG intensity (no red). Scale bar: 100 μm. (c) Correlation histogram between the SHG intensity and the interferometric contrast (Pearson coefficient 0.6). (d) Correlation histogram between the SHG intensity and the anisotropy parameter (Pearson coefficient 0.3). To see this figure in color, go online. Biophysical Journal  , DOI: ( /j.bpj ) Copyright © 2015 Biophysical Society Terms and Conditions


Download ppt "Volume 109, Issue 12, Pages (December 2015)"

Similar presentations


Ads by Google