1 I-99 HPC Permeability Testing
Presented By Geoffrey Kurgan 17 May 2002

2 Current Testing AASHTO T 277/ASTM C 1202 14 mixture designs
2 material sources Fly Ash, GGBFS, PC, Silica Fume and multiple ternary mixes Through 56- day test for all combinations Normal curing temperature and conditions Samples fabricated for one year tests

3 Current Testing- Test Setups
Two test setups allow numerous tests to run each day Comparable results on either machine

4

5

6 Future Test Plans AASHTO T 277/ASTM C1202 AASHTO T 259
Accelerated Curing AASHTO T 259 Modified Rapid Migration Test (RMT) Pressure permeability

7 Test Plan

8 Test Plan- AASHTO T 277 Rapid chloride permeability test
Continue fabrication and testing of additional samples Accelerated curing for 28- day test 7 day MC 23C + 21 day MC 38C 7, 28, 56, 90, 180, and 365 day tests

9 Test Plan- AASHTO T 259 Salt ponding test
3% NaCl solution ponded on top surface for 90 day intervals 0.5” slices taken at progressive depths to determine chloride concentration Run for 180 days

10 Test Plan- Rapid Migration Test
Based on test developed in Sweden and modified at the University of Toronto Silver nitrate solution used to highlight penetration depth Seven measurements recorded for average Chalmers Technical University

11 Test Plan- Pressure Permeability
Currently under construction Chloride profile grinding Depth penetration measurement using silver nitrate Darcy’s Law utilized to yield permeability coefficient