Download presentation
Presentation is loading. Please wait.
Published byWilfred Owen Modified over 5 years ago
1
Critical parameter of burst pressure measurement in development of bypass grafts is highly dependent on methodology used Sandip Sarkar, MA, MRCS, Claire Hillery, BSc, PhD, Alexander Seifalian, PhD, George Hamilton, MD Journal of Vascular Surgery Volume 44, Issue 4, Pages (October 2006) DOI: /j.jvs Copyright © 2006 The Society for Vascular Surgery Terms and Conditions
2
Fig 1 Summary of the different burst pressure-measuring techniques.
Journal of Vascular Surgery , DOI: ( /j.jvs ) Copyright © 2006 The Society for Vascular Surgery Terms and Conditions
3
Fig 2 Burst pressures obtained via the different measuring techniques. Data are mean ± SD of six experiments. Keys: *P < .001 vs no latex lining; †P > .05 vs 0.2 mL/min; ‡P < .05 vs 0.2 mL/min; §P > .05 vs 50 mL/min. Journal of Vascular Surgery , DOI: ( /j.jvs ) Copyright © 2006 The Society for Vascular Surgery Terms and Conditions
4
Fig 3 Subjecting the graft with an interconnected porous structure to intraluminal pressure of 300 mm Hg leads to “sweating” of water through the wall. Journal of Vascular Surgery , DOI: ( /j.jvs ) Copyright © 2006 The Society for Vascular Surgery Terms and Conditions
5
Fig 4 The aneurysmal point is a more accurate term than burst pressure, defined as the point at which further infusion at the same rate does not result in any increase in pressure (in this case 347 mm Hg). Journal of Vascular Surgery , DOI: ( /j.jvs ) Copyright © 2006 The Society for Vascular Surgery Terms and Conditions
Similar presentations
© 2024 SlidePlayer.com Inc.
All rights reserved.