T.S SEIUN MARU AUXILIARY BOILER Third Engineer 2019/2/19 ボイラ.

Similar presentations


Presentation on theme: "T.S SEIUN MARU AUXILIARY BOILER Third Engineer 2019/2/19 ボイラ."— Presentation transcript:

1 T.S SEIUN MARU AUXILIARY BOILER Third Engineer 2019/2/19 ボイラ

2 PREFERENCE OF AUX’ BOILER
蒸気出口 ガス出口 2019/2/19 ボイラ

3 PERFORMANCE OF AUX BOILER
Type:MITSUBISHI MC-30D Steam pressure :0.59MPa Feed water temperature :60℃ Evaporation :3000kg/h Main Fuel :C heavy oil 2019/2/19 ボイラ

4 ARRANGEMENT Water drum (top) Evaporation tubes Soot blower
Inspection hall Access Door Outlet for exhaust gas Oil burner Water drum (bottom) Furnace 2019/2/19 ボイラ

5 Atmospheric Condenser
Boiler FO Supply Pump Supplies FO or DO from each service tank to FO burning pump. Forced Draft Fan Supplies air for combustion, pre­purge and post­purge on aux. boiler Soot Blower Operation for Removing the soot attached on the heating tubes of aux. boiler or exh. gas economizer with steam. It has done in periodically to keep the thermal efficiency and prevention of getting damage of heating tubes. Inspection Tank Inspects the oil incorporation into the drain from heating steam drain. So called as Observation tank too. Feed Filter Tank Removes the oil and impurity materials from condensate water (boiler feed water). Atmospheric Condenser As a role , condensation the steam drain from the tank-heating line and several heaters with low temp cooling fresh water. 2019/2/19 ボイラ

6 BOILER FO SYSTEM 2019/2/19 ボイラ

7 BURNER FRONT IGNITER BURNER FDF MOTOR 2019/2/19 ボイラ

8 SAFETY VALVE 2019/2/19 ボイラ

9 Feed Water Control Valve
給水を制御する 2019/2/19 ボイラ

10 WATER LEVEL GAUGE 2019/2/19 ボイラ

11 STEAM SERVICE LINE 2019/2/19 ボイラ

12 AUTOMATIC COMBUSTION TIME CHART
2019/2/19 ボイラ

13 BURNER AUTOMATIC OPERATION
《 START 》 IGNITION to MAIN BURNER STEAM PRESS UNDER 0.49MPa START FO BURNING PUMP & F.D.F. PRESSURE RISE EXTINCTION PILOT BURNER PRE - PURGE ( 90 sec ) IGNITION to HIGH/LOW BURNER IGNITION to PILOT BURNER STEAM PRESS REACH to 0.59MPa WORKING of FLAME EYE EXTINCTION HIGH/LOW BURNER 2019/2/19 ボイラ

14 STEAM PRESS REACH to 0.62MPa
BURNER AUTOMATIC OPERATION 《 STOP 》 STEAM PRESS REACH to 0.62MPa EXTINCTION MAIN BURNER & STOP FO BURNING PUMP POST – PURGE ( 60 sec ) STOP F.D.F. 2019/2/19 ボイラ

15 About the important word・・・
・PREPURGE This operation is for ventilation before the ignition to prevent a backfire . ・POSTPURGE This operation is for ventilation after the extinction to remove the remaining gas inside the combustion chamber. This operation prevent the corrosion . 2019/2/19 ボイラ

16 BOILER WATER TREATMENT
BOTTOM BLOW SURFACE BLOW BOILER WATER ANALYSIS FILTER (FEED FILTER TANK) APPLING THE CHEMICAL (Tertialy Sodium Phosphate) (Sodium Hydroxide) 2019/2/19 ボイラ

17 BOILER WATER ANALYSIS PH (at 25℃) 11.0~11.8 P-ALKALINITY 80 ~600 ppm
M-ALKALINITY ~800 ppm Cl- Max.400 PO ~40 HARDNESS Max.1 ppm 2019/2/19 ボイラ

18 Necessary for BLR water Analysis and treatment
・prevention of sticking the scale When the scale stick on the tube , the place will be superheated. Finally , scale will bring the trouble(burst and crack…).Beside of that, it will be source of decreasing the thermal efficiency. ・prevention of corrosion The place where exposed with boiler water gets the corrotion with efficiency of ionize. ・prevention of carry-over Phenomenon of bringing out the boiler water with steam. It’s will be a source of decreasing the thermal efficiency and corrosion because of impurities inside the boiler water. 2019/2/19 ボイラ

19 SAFETY DEVICE EMERGENCY TRIP ALARM LOWEST WATER LEVEL
FO LOWEST TEMPERATURE FO LOWEST PRESS IGNITION FAIL FLAME FAIL SOURCE FAIL FDF STOP EMERGENCY STOP (BOILER SIDE & C/R) ALARM LOW WATER LEVEL HIGH WATER LEVEL FO LOW TEMPERATURE FO HIGH TEMPERATURE FO LOW PRESS 2019/2/19 ボイラ

20 Burner Maintenance To keep a good combustion , we have a maintenance in regularly . Above all,the accumlation of the carbon around the igniter and pilot burner invite the bad ignition. When the carbon stick around the swirler,it retard the ventilation.

21 PERFORMANCE OF EXH.GAS ECONOMIZER
HEATING SURFACE : ㎡ WORKING PRESSURE : MPa STEAM TEMPERATURE : saturated FEED WATER TEMPERATURE :60℃ CAPACITY : 1000Kg/h 2019/2/19 ボイラ

22 BOILER WATER CIRCURATING LINE
2019/2/19 ボイラ

23 Heating Tube 2019/2/19 ボイラ

24 STEAM LINE & DUMPING SYSTEM
STEAM PRESS OVER 6.8kg/c㎡ 2019/2/19 ボイラ

25 Dumping valve Set Press : 0.67 MPa 2019/2/19 ボイラ

26 Washing the heating tubes