Presentation is loading. Please wait.

Presentation is loading. Please wait.

The Fill Pattern Monitor For the Australian Synchrotron

Similar presentations


Presentation on theme: "The Fill Pattern Monitor For the Australian Synchrotron"— Presentation transcript:

1 The Fill Pattern Monitor For the Australian Synchrotron
David Peake Supervisors: Dr Roger Rassool Dr Mark Boland

2 The Australian Synchrotron
3 GeV 100 MeV

3 The Storage Ring 720 ns

4 Aims of This Project Quantify beam characteristics
Optimize injection parameters to: increase the maximum stored current increase the lifetime of the beam Lower the frequency of re-injection

5 Initial Beam Profile Injected current is not evenly spread
Current example of beam profile: 720 ns

6 An Ideal Beam Profile Stored current is spread evenly across the entire period 35 ps 720 ns 2 ns

7 û ü û ü Measurement Methods Directly measure the electrons in the ring
Measure the synchrotron light X-rays Visible Light ü û ü

8 The Requirements A photodiode with a super fast rise time
A digitiser with a rapid sampling rate In our device the key component will be a high speed MSM photodiode

9 MSM Photodiode

10 ü ü ü Experimental Setup Fill Pattern Monitor (FPM) DC-30 GHz 14 GHz
Bending Magnet 1 Electron beam X-rays (Not to Scale) Optical Chicane Fill Pattern Monitor (FPM) MSM AMP DIG Visible Light ü ü ü DC-30 GHz 14 GHz 8 GS/s

11

12 Results Tuesday 17th of October – 12:15 am A single bunch was measured

13 How do we know? Need to validate the results against well used diagnostic devices

14 Injection Delay Placed a delay into the injection timing, and injected from the booster ring.

15 Australian Synchrotron Milestone
Two days later, the FPM was used to achieve the following major milestone… A maximum current of 100 mA A beam lifetime of 12 hours (a 50% increase) “Couldn’t get the smiles off their faces”

16 Continuous Top Up Mode The Australian Synchrotron is now capable of running in continuous top up mode This is a world first

17 Summary Able to digitise a single 35 ps light pulse
Can measure the beam profile in real time Information from the FPM has already resulted in a higher maximum current and a 50% increase in beam lifetime.

18 Acknowledgements Dr Roger Rassool Dr Mark Boland
The Accelerator Group at the Australian Synchrotron.


Download ppt "The Fill Pattern Monitor For the Australian Synchrotron"