A Closed Perfusion System With Heparin Coating and Centrifugal Pump Improves Cardiopulmonary Bypass Biocompatibility in Elderly Patients  Lena Lindholm,

Similar presentations


Presentation on theme: "A Closed Perfusion System With Heparin Coating and Centrifugal Pump Improves Cardiopulmonary Bypass Biocompatibility in Elderly Patients  Lena Lindholm,"— Presentation transcript:

1 A Closed Perfusion System With Heparin Coating and Centrifugal Pump Improves Cardiopulmonary Bypass Biocompatibility in Elderly Patients  Lena Lindholm, ECCP, PhD, Martin Westerberg, MD, Anders Bengtsson, MD, PhD, Rolf Ekroth, MD, PhD, Eva Jensen, MD, PhD, Anders Jeppsson, MD, PhD  The Annals of Thoracic Surgery  Volume 78, Issue 6, Pages (December 2004) DOI: /j.athoracsur Copyright © 2004 The Society of Thoracic Surgeons Terms and Conditions

2 Fig 1 Cardiopulmonary bypass (CPB) time and interleukin-6 (IL-6) concentrations during rewarming in the biocompatible group (squares) and in the conventional group (triangles). There was a significant correlation between the two variables (p < 0.001). The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2004 The Society of Thoracic Surgeons Terms and Conditions

3 Fig 2 Soluble complement fragment (sC5b-9) and polymorphonuclear (PMN) elastase concentrations during rewarming in the biocompatible group (squares) and in the conventional group (triangles). There was a significant correlation between the two variables (p < 0.001). The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2004 The Society of Thoracic Surgeons Terms and Conditions