API 6A VR Plug Work February 2016 Report David Zollo / Tom Lambert

2 4” HPVR Testing Update Proof test conducted at 30K and room temperature (2x). Tested to working pressure (20Kpsi) 10x at room temperature. Visual inspection of plug and o-ring conducted. No damage to either plug or o-ring O-ring was 80 duro FKM but material is not specified in 6A (PMR to address application) Plug tested was manufactured from k material Testing completed at -20F to +300F Reporting – Per Tom Lambert – Still awaiting validation report from Stress Engineering. Tom will send design package for API file No other HPVR sizes have been tested  