Presentation is loading. Please wait.

Presentation is loading. Please wait.

Volume 95, Issue 3, Pages (August 2008)

Similar presentations


Presentation on theme: "Volume 95, Issue 3, Pages (August 2008)"— Presentation transcript:

1 Volume 95, Issue 3, Pages 1474-1486 (August 2008)
Three-Dimensional Microtubule Behavior in Xenopus Egg Extracts Reveals Four Dynamic States and State-Dependent Elastic Properties  Philipp J. Keller, Francesco Pampaloni, Gianluca Lattanzi, Ernst H.K. Stelzer  Biophysical Journal  Volume 95, Issue 3, Pages (August 2008) DOI: /biophysj Copyright © 2008 The Biophysical Society Terms and Conditions

2 FIGURE 1 Measuring three-dimensional microtubule dynamic instability and elasticity. (a) Illustration (to scale) of the light-sheet imaging arrangement (SPIM). The detection lens in the central SPIM imaging chamber is immersed in water. The light sheet is focused into the chamber from the side and illuminates a single plane of the specimen. (b) The sample cylinder containing the egg extract is attached to a glass capillary and oriented parallel to gravity. The cylinder is located in front of the detection lens and can be moved along three dimensions via a set of linear miniature stages. The detector elements, including the microscope objective lens, are in a horizontal arrangement. Its focal plane is coplanar with the light sheet. The optical sectioning capability introduced by the light sheet profile reduces photobleaching in three-dimensional imaging by a factor of (sample thickness)/(light-sheet thickness) as compared to a conventional microscope, which results in a factor of 20 for experiments of microtubule dynamic instability. (c) The microtubule asters are polymerized in the egg extract inside the Teflon cylinder. The cylinder has a diameter of 2 mm and consists of a Teflon membrane with a thickness of 25μm (bioFOLIE 25, In Vitro Systems & Services, Germany). The membrane has a high transmittance for visible wavelengths and is refractive-index-matched to water (but not water-permeable). Due to the high viscosity of the egg extract, the polymerized asters can be kept in a stable position anywhere inside the cylinder. The distance between the cylinder's surface and the recorded asters is in the order of 100μm. Three-dimensional data are recorded by moving the microtubule asters in small z-steps through the light sheet while simultaneously recording images with the CCD camera. (d) Maximum-intensity projections at nine time points of a three-dimensional dynamic instability time-lapse data set, recorded with SPIM. Scale bar, 10μm. The arrow in the last frame indicates the microtubule that is shown in Fig. 4 a. Tubulin was labeled at a 5% ratio with Alexa-488. Elapsed time is relative to the start time of imaging. For all experiments, imaging starts 1–2min after the onset of microtubule polymerization. Fluorescence was detected via the Carl Zeiss Achroplan W 100×/1.0 lens. Biophysical Journal  , DOI: ( /biophysj ) Copyright © 2008 The Biophysical Society Terms and Conditions

3 FIGURE 2 Automated phase fitting in microtubule length-versus-time diagrams. Manual tracking data of 11 microtubules (gray) and the corresponding dynamic phases automatically computed by the phase-fitting algorithm (black). The spatial error of the length measurements is also indicated in gray. Data set 1 shows a switching from growth to g-pause. Data set 2 illustrates a positive growth contrast with intermediate g-pause. Data set 3 exhibits an example of growth-speed switching. Data set 7 shows a rescue event. Biophysical Journal  , DOI: ( /biophysj ) Copyright © 2008 The Biophysical Society Terms and Conditions

4 FIGURE 3 The three kinetic models of microtubule dynamic instability. (a) The conventional two-state model of microtubule dynamic instability, introduced by Terrell Hill (34). Parameters resulting for our three-dimensional data are indicated. Microtubule pausing is not considered in this model. (b) The three-state model of microtubule dynamic instability, derived by extending the two-state model by one pause state and introducing four additional state transitions. (c) The four-state model, with two independent pause states, comprising the growth state, the shrinkage state, the pause-after-shrinkage (s-pause) state, and the pause-after-growth (g-pause) state. The four-state model considers transitions that involve at most one of the two pause states. Transitions between the two pause states cannot be determined by observation with conventional microscopy and are therefore not quantified. The errors of the average speeds are standard errors of the mean (SE). The errors of the transition frequencies are calculated by dividing the respective frequency by the square root of the number of underlying observation events. The errors of the pause state probabilities arise from unidentified pause phases, i.e., pauses for which the preceding dynamic phases were not observed. Biophysical Journal  , DOI: ( /biophysj ) Copyright © 2008 The Biophysical Society Terms and Conditions

5 FIGURE 4 Three-dimensional mechanics of dynamic microtubules in interphase egg extracts. (a) Maximum-intensity projections of the three-dimensional contour shape of an unconstrained microtubule at 15 time points of a dynamic instability time-lapse data set (Fig. 1 d, arrow). Microtubule bending is caused by thermal fluctuations. Three-dimensional tip deflections and minus-end tangents (green) (Fig. 4 b) are automatically computed from the microtubule tracing points. Images are rotated such that the minus-end tangents are vertically oriented. Scale bar, 10μm. (b) Schematic concept of the three-dimensional deflection measurements. The microtubules are “clamped” at their minus ends, which are embedded in the centrosome's matrix. The deflection ratio d/L is a direct measure of the filament's elasticity. (c) The global statistics of deflection ratios, obtained from n=1817 independent three-dimensional measurements of microtubules with different contour lengths. The red curve indicates the best fit obtained with the one-parameter model (Eq. 18). The resulting effective persistence length, lp=1.8±0.4mm characterizes the entire population of microtubules in the length regime L=10–45μm. The microtubule length distribution has been considered according to Eq. 2. The frequency errors are introduced by data binning. The numerical error of the persistence length includes the error of the fit and a conservative estimate of the spatial error in the deflection measurements (Data S1). (d) Analysis of the persistence length's filament-length dependency. The total statistics was subdivided into the length intervals 10–15, 15–20, 20–22.5, 22.5–25, 25–30, 30–35, 35–40, and 40–50μm. The microtubule length error is the standard deviation of the bin size a/3, with a=2.5or 5μm. The error of the persistence length is calculated as described in Fig. 4 c. (e) Effective persistence lengths for growing (upper, n=1441) and pausing (lower, n=321,) microtubules in the microtubule length regime 10–45μm. Fitting and errors as in Fig. 4 c. Biophysical Journal  , DOI: ( /biophysj ) Copyright © 2008 The Biophysical Society Terms and Conditions


Download ppt "Volume 95, Issue 3, Pages (August 2008)"

Similar presentations


Ads by Google