Download presentation
1
PRESENTATION iNELS 1 1 1
2
CHARACTERISTICS iNELS® is a smart wiring system designed especially for: switching dimming control and measurement monitored state of object integration of multimedia installation bus CIB: communication and power supply units actors (receivers) and sensors (transmitters) and data telegrams IDM software-assigned functions and operating parameters Presentation iNELS 2 2 2
3
SYSTEM OPTIONS OF iNELS
switching and dimming of lighting Detection of indoor and outdoor movement and light intensity motion control blinds, shutters, awnings, garage, doors, entrance gates etc. management systems, heating and air conditioning control various appliances (with interlocks on selected priorities) integrated electronic security alarm Remote Access (GSM and Internet) visualization - IDM, iMM Presentation iNELS 3 3
4
THE POSSIBILITY APPLICATION OF iNELS
Houses (lighting, heating, air conditioning, ventilation, blinds, etc.) Presentation iNELS 4 4 4
5
THE POSSIBILITY APPLICATION OF iNELS
Apartment buildings (plus common area management) Presentation iNELS 5 5 5
6
THE POSSIBILITY APPLICATION OF iNELS
Cottages (plus remote access) Presentation iNELS 6 6 6
7
THE POSSIBILITY APPLICATION OF iNELS
Hotels and restaurants (the central feature scenes) Presentation iNELS 7 7 7
8
INSTALLATION BUS CIB communication protocol is an internal (company)
communication protocol is an internal (company) response time of the entry into a central unit to output up to 150 ms free topology: Linear Linear Star Tree and their combinations Tree Star Presentation iNELS 8 8 8
9
PARAMETERS INSTALLATION BUS CIB
CU2-01M separate branches directly to CIB - 4 more branches CIB via external masters CP separate branches directly to CIB - 8 more branches CIB via external masters total length of one branch (line) CIB may be 550 m on each branch 32 HW addresses, is 32 units iNELS 1A maximum load for each branch of the CIB Presentation iNELS 9 9 9
10
PARAMETERS INSTALLATION BUS CIB
1 CIB branch: The physical limit 1A Logical limit 32 address Length 550m Total: Number of iNELS units CU2-01M 192 CP-1000 320 Presentation iNELS 10 10 10
11
SYSTEM BUS TCL2 System with linear bus topology
System with linear bus topology Connecting external master module MI2-02M, which allow increasing the number of branches (lines) installation bus CIB Maximum length of TCL2 bus is 300 m Recommended cable J-Y(St)-Y 2x2x0.8 Ends with a resistance with value 120 Ω Presentation iNELS
12
SUMMARY - GENERAL PRINCIPLES FOR THE MANAGEMENT BUS
GENERAL PRINCIPLES FOR THE MANAGEMENT BUS Accumulation of bus lines with power lead : We recommend to avoid accumulation the power lead. Alternatively, a minimum distance from power lines 30 cm Conditions for bus line : Recommended cables Electromagnetic interference is avoided Cable at any point is mechanically damaged Cable must not be mechanically stressed (must be respected technology installation procedures, temperature, bend radius, modes of attachment) Presentation iNELS
13
DESIGN OF SYSTEM ELEMENTS
M DI/AC TI/AI Modul „M“ - Installation on DIN rail DO AO B DI/AC TI Box „B“ - installation into a wiring box DO AO E/G DI TI Wall drivers DO Presentation iNELS
14
Central Unit CU2-01M Ethernet 10/100 Mbit/s power 27.2V DC, 24V DC
27.2 VDC CIB 1 CIB 2 TCL2 RS232 Ethernet 10/100 Mbit/s power 27.2V DC, 24V DC 2x interfaces CIB 1x interfaces TCL2 1x serial chanel RS-232 2x PSM Ethernet 10/100base 4x DI (IN1 - IN4) 1x DO integrated WEB server SW IDM, SCADA/HMI Reliance, OPC server PSM 4x DI 1x DO Presentation iNELS
15
External Master CIB MI2-02M
TCL2 2 branch of CIB bus more (identifying, addressing and configuration of units), data processing and transfer them to CU2-01M Circle switch 1x TCL2 LED diod Circle switch is used for setting the address of MI2-02M on the TCL2 bus CIB LEDs for identification communication on the CIB bus CIB Presentation iNELS
16
GSM Gate - GSM2-01 32 phones numbers
27.2 VDC RS232 32 phones numbers 48 outgoing SMS each on a 20-digit 32 incoming SMS each on a 20-digit RMSA defined dialing phone numbers and ringing for 20 sec and end You can define actions on incoming calls Presentation iNELS
17
Bus separator for power supply BPS2-02M
27.2 VDC 2x CIB ensures the correct power of two branches (lines) CIB, separates power supply units from peripheral and communication master terminals for connection 27.2VDC source AKU terminals for connecting back- up battery terminals +27 V and GND for power supply and CU GSM2 27.2 VDC AKU 2x CIB interfaces Presentation iNELS
18
Connections of BPS2-02M A CU2-02M
Presentation iNELS
19
Connections of BPS2-02M A MI2-02M
Presentation iNELS
20
2x, 4x, 8x a 14x DI balancing option for alarm
Binary input - IM2-20B, IM2-40B, IM2-80B, IM2-140M CIB 12 VDC 1x TI CIB 12 VDC 14x DI CIB 12 VDC 1x TI CIB 12 VDC 1x TI 2x DI 4x DI 8x DI 2x, 4x, 8x a 14x DI balancing option for alarm 14x DI contact inputs can be defined as NC / NO output 12V DC / 75 mA (150 mA) for power of alarm units Presentation iNELS
21
4x AI the common terminal GND
Temperature input - TI2-40B, Analog input ADC2-40M CIB CIB 1x AI CIB 4x TI 4x AI the common terminal GND input - U, I a RTD selectable ranges A / D converter resolution 14 bit For powering passive resistive sensor termin al with a reference voltage 5.4V 4x TI 3x AI 4x TI - connection resistance temperature sensors TC/TZ only in version IDM Presentation iNELS
22
Dimming actuator - LM2-11B
CIB CIB 1x TI switching and dimming load RLC autodetection of load 1x TI 1x a 2x DI (230V AC) 1x a 2x AO (250 VA) 1x DI 1x AO Presentation iNELS
23
Dimming actuator - DA2-22M
switching and dimming load RLC, LED, (ESL) CIB CIB 1x TI 1x TI 1x a 2x DI (230V AC) 1x a 2x AO (500 VA) Setup load and minimum brightness with potentiometers on the front side. potential at terminal L on DA2-22M is recommended to protect the safety element corresponding to the connected load (fuse characterized. F) 2x DI 2x AO Presentation iNELS
24
Dimming actuator - DIM-6
CIB 1x AI 10 kW switching and dimming load RLC hw setup of load (jumper) 1x AO (2000 VA) 1x AI (0-10 V, 1-10 V) modular expandable up to VA 1x DI 1x AO Presentation iNELS
25
Dimming actuator - LBC2-02M
CIB CIB 1x DO control dimmable ballasts for fluorescent tube 2x AO (1-10 V) 2x DO (RO) (16 A/4000 VA AC1) 2x AO 1x DO Presentation iNELS
26
Switching actuator - SA2-01B, SA2-02B
CIB CIB 1x TI CIB CIB 1x TI switching appliances and loads 2x DO (RO) - floating switching contact Relay contact 16 A/4000 VA AC1 - SA2-01B, 8 A/2000 VA AC1 - SA2-02B 1x DO 1x DO 1x DO Presentation iNELS
27
Shutters actuator - JA2-02B , JA2-02/DC
motion control shutters, blinds etc. CIB 1x TI CIB 1x TI JA2-02B - 2x RO 4 A/1000 VA AC3 JA2-02B/DC - 2x RO - drives with supply voltage of 24V DC, direction of rotation is controlled by changing the polarity of the motor L DOWN UP ◄ ◄ U Presentation iNELS
28
Switching actuator - SA2-02M, SA2-04M
CIB CIB CIB CIB 1x DO switching appliances and loads 2x DO (RO) - SA2-02M - floating switching contact 16 A/4000 VA AC1 4x DO (RO) - SA2-04M – floating switching contact 16 A/4000 VA AC1 1x DO 1x DO 1x DO 1x DO 1x DO Presentation iNELS
29
Switching actuator - SA2-012M
CIB 230 V AC 4x DO switching appliances and loads 12x DO (RO) – switching contact 8 A/2000 VA AC1 each of four identical outputs switching the same potential power for unit is 230V AC 4x DO 4x DO Presentation iNELS
30
Analog output - DAC2-04B, DAC2-04M
CIB CIB CIB CIB 1x TI 4x AO V, 1-10V control devices that are controlled by this signal (dimmable ballasts of fluorescent lamps, dimmers, thermoelectric valves, servo drives, instrumentation element) 4x AO 4x AO Presentation iNELS
31
Thermovalve controler - HC2-01B/AC, HC2-01B/DC
switching thermoelectric heads 0/1 CIB CIB 1x TI CIB CIB 1x TI HC2-01B/AC – 1x DO V AC Maximum peak current A/230V AC HC2-01B/DC – 1x DO - 24V DC Maximum peak current A/30V DC 1x AO V 1x DO 1x DO 1x AO Presentation iNELS
32
Multifunction control unit - SOPHY2, SOPHY2-L
sensor of the human voice ambient light intensity sensor 1x DI 4x DI 1x TI - integrated temperature sensor IR receiver IR transmitter 6x DI CIB 1x DI design in a LOGUS90 Presentation iNELS
33
Wall Switch - WSB2-20, WSB2-40, WSB2-80
integrated micro-switches with a low stroke design: WSB x DI, 2x DO CIB CIB WSB x DI, 4x DO WSB x DI, 8x DO 1x TI - integrated temperature sensor design in a LOGUS90 Presentation iNELS
34
Termoregulator - IDRT2-01
control temperature and heating circuit 1x TI Mode 1x AI - correction in the range +/- 3°C 2x DO indicate LED design in Logus90 State Korekce Presentation iNELS
35
Touch screen - EST2, EST2/RGB
3,5“ touch screen It consists of 3 (4) iNELS elements : IM2-140M, IDRT2, KEY2-01, (ADC2-40M) 2(3) main screen: With configurable icons, with digital controller for temperature corection, (screen for RGB control) design in a LOGUS90 Presentation iNELS
36
EST2 configurable icons
Option 4-12 icons 48 different icons in librery Distinguishes between long and short press configuration is setup via binary inputs IM2-140M Design in a LOGUS90 Presentation iNELS
37
EST2 termostat a RGB control
Presentation iNELS
38
EST2 connection for control RGB
Presentation iNELS
39
THANK YOU FOR YOUR ATTENTION
THANK YOU FOR YOUR ATTENTION Martin Ševela Product manager P a l a c k e h o | Ho l e s o v, V s e t u l y | Cz e c h R e p u b l i c t e l . : | f a x : | e l k l k o e p . c om | www. e l k o e p . c om Presentation iNELS
Similar presentations
© 2025 SlidePlayer.com Inc.
All rights reserved.