Presentation is loading. Please wait.

Presentation is loading. Please wait.

Vamos + Exogam Spectrometer

Similar presentations


Presentation on theme: "Vamos + Exogam Spectrometer"— Presentation transcript:

1 Vamos + Exogam Spectrometer

2 Goals VAMOS was designed for spectroscopy studies
using different reaction types in particular induced by low intensity radioactive beams Advantages large acceptance variable mode Coupling with EXOGAM TIARA, DIAMANT INDRA (Neutron Wall) Main working modes magnetic spectrometer separator

3 VAMOS Spectrometer Schematic View
QUADRUPOLES EXOGAM BEAM Focal Plane detection DIPOLE Velocity Filter

4 VAMOS in reality

5 Specifications Quadrupoles (850 A) Q1 Q2 Magnetic length [m] 0.6 0.9
Field gradient [T/m] Bρ full(reduced) Ω [Tm] (2.2) Dipole (850 A) Magnetic field [T] 1.2 Magnetic length [m] 1.57 Deflection radius [m] 1.5 Bρ at 60° [Tm] 1.8 Wien Filter Length [m] 1 Gap [m] 0.15 E [kV] 300 B [T] 0.2

6 Specifications Path length 7.3 m Rotation 0°-90°
Solid angle 100 msr Translation m Momentum ±7 % Focal Plane Dispersion 2.5 cm/% Angle 0°-60° Example: Θ : -100, +100 [mrad] Bρ : (0.97,1,1.03)BNc

7 Light/Fast Ion Detection Dispersive Plane
Drift Chamber X: charge distribution 2 x 64 pads (6.3x50) mm XFWHM ~200 μm Y: drift time YFWHM ~ 500 μm Ionisation Chamber 2 x 7 pads (50x50) mm 1 x 7 pads (50x 170)mm ΔEFWHM ~ 3% Plastic Detector EFWHM ~ 4% Silicon Wall

8 Heavy/Slow Ion Detection
Ionisation Chamber Secondary electron Detector Se-D XFWHM ~ 1 mm YFWHM ~ 2 mm TFWHM ~ 300 ps Mylar emissive foil

9 VAMOS Measurement Resolution Θ 0.1° Φ 0.3° Bρ 0.5% M/q 0.5% q 1/30
Θ 0.1° Φ 0.3° Bρ 0.5% M/q 0.5% q 1/30 M 1/200 Z 1/30 φf θf V M/q M q Z φ θ Yf Xf TOF ΔE E M/q ~ Bρ x TOF M ~ E x TOF2 Z2 ~ E x ΔE ~ ΔE/TOF2

10 EXOGAM 12 closely packed Compton suppressed Ge segmented clover
detectors Efficiency ~ 12% at 1.33 MeV

11

12 Deep Inelastic Collisions measured with VAMOS
dE vs E

13 Deep Inelastic Collisions measured with VAMOS
M vs M/Q

14 Search for 2+ in 54Ca magicity at N=34
-10 -5 f5/2 p1/2 p3/2 f7/2 48Ca 54Ca Large experimental effort to estimate this gap from studies of nearby nuclei. Direct information on this gap is the 2+ energy. Pronounced shell gap in 54Ca

15 Identification spectra
dE vs E dE vs E M vs M/Q

16 Spectra of 50Ca γ-γ projection γ-γ projection γ-γ gate

17 Spectra of 52Ca

18 Recoil (Decay) Tagging
Reaction: + 208Pb -> 222Th + 4n Time stamping: Time correlations measured using the universal clock CENTRUM SetUp: EXOGAM VAMOS at 0º with focal plane at 10º using WIEN filter focal plane detection: SeD, SiWall

19 Recoil Decay Tagging


Download ppt "Vamos + Exogam Spectrometer"

Similar presentations


Ads by Google