Presentation is loading. Please wait.

Presentation is loading. Please wait.

Cath Lab Catastrophes : Prevention & Management Strategies

Similar presentations


Presentation on theme: "Cath Lab Catastrophes : Prevention & Management Strategies"— Presentation transcript:

1 Cath Lab Catastrophes : Prevention & Management Strategies
CRT 2013 , Washington DC February 23-26th,2013 Cath Lab Catastrophes : Prevention & Management Strategies Fayaz Shawl, M.D., F.A.C.C. Director Interventional Cardiology Washington Adventist Hospital - Takoma Park, Maryland Clinical Professor of Medicine George Washington University - Washington, D.C.

2 Research Support : Boston Scientific Cordis ( J&J ) Medtronic Abbot
Fayaz Shawl, MD Research Support : Boston Scientific Cordis ( J&J ) Medtronic Abbot

3 Cath Lab Catastrophes Crash bypass Urgent bypass P value Results:
OR mortality 6/19 (32%) 1/56 (2%) * Hospital stay (8.04) (8.86) In-hospital mortality9/19 (47%) /56 (5%) * JA Carey,et al, Br Heart J 1994;72:

4 Etiology : Cath lab Catastrophes
Vessel closure (Dissection,thrombus,Spasm, and no-reflow) Introduction of Air, thrombus Perforations Anaphylaxis Major Bleed High Risk Patient

5 Management of Cath lab Catastrophes
Don’t Panic BP support ; Airway Call for an extra-hand QUICK -- Underlying Etiology

6 Cath Lab Catastrophes:
Clinical Features: ♥ Refractory Hypotension ♥ Loss of consciousness ♥ Respiratory arrest ♥ Wide QRS rhythm / PEA ♥ Ventricular Fibrillation ( Refractory) ♥ Chest compressions

7 Cath Lab Catastrophes:
Angiographic and Hemodynamic Features ♥ Occluded vessel (large viable area) ♥ Left main dissection ♥ No reflow in a major vessel (SVG) ♥ Poor clearance of dye (aortic root) ♥ Major Perforation / thrombosis/Air ♥ Narrow pulse pressure ♥ Pulmonary hypertension ♥ Worsening metabolic acidosis

8 Cath Lab Catastrophes:
LVAD ( indications ) Absence of intrinsic rhythm

9 Historical Perspectives- LVAD
Impella 70’s 80’s 90’s ’s

10 Approved Percutaneous LVADs:
1. IABP 2. CPS ( ECMO) 3. Tandem Heart 4. Impella

11 Cath Lab Catastrophes: ? When Death is Imminent
Management (Requiring chest compressions) ♥ Intubation ♥ Continuation of chest compressions ♥ Emergency institution of cardiopulmonary bypass support ( ECMO ) ♥ Replace angiographic access site with CPS cannulae ♥ Flow rate 50 ml/kg/min ♥ Contralateral groin access to re-assess anatomy ♥ Re-Intervention / Emergency Surgery

12 56 yr. Old F, CTO LCX, RCA

13 75yr..male –CTO RCA, for PCI to LAD

14

15

16 CORONARY AIR EMBOLUS

17 CORONARY AIR EMBOLUS

18

19

20 Air Embolus Often from manifold injections (contrast or flush )
and during introduction of devices - TB) Prevention Avoid pressurized flush Back bleed before injecting Small amounts are well tolerated Large amounts cause “Air Lock” Chest Pain Bradycardia Hypotension / Hemodynamic Collapse

21 Air Lock: Management Don’t Panic 100% O2 Morphine, Atropine
Neo-synephrine 0.1 mg. IV I/C Epinephrine 1:10,000 dil. Turn patient Suction / Flushing IABP LV assist Devices (for refractory hemodynamic collapse)

22 85 yr. female – Class III – PCI - LAD

23 DES X 23mm- 16 Atm-

24 Type III…………

25 Prolonged Balloon Inflation

26 Refractory Cardiac Arrest- VF

27 Covered Stent- with CPS

28 Still in VF- stable Hemodynamics'… On CPS – 4L/min- Note long sheath

29 Post – Covered Stent – Defib. To NSR

30

31 Coronary Perforation Occurs in between 0.1% - 0.7%
More with ablative devices More with oversizing the devices Hydrophilic guide wire, Temp. Pacemaker Early recognition is key to a successful outcome Highest mortality among all PCI complications

32 JOSTENT (PTFE) To Treat Coronary Perforations
Overall Perforation Rate 0.45% (49 / 10,945) PTFE (n=12) Non-PTFE (n=37) P-value In-Hospital Outcome QMI (%) 8 23.5 0.29 Cardiac Tamponade (%) 82 <0.001 Bypass Surgery (%) 18 88 Death (%) 35 0.28 C. Briguori et al, Circulation 2000

33 Coronary Perforation Rapid recognition is key
Cardiac tamponade and hemodynamic collapse can occur in minutes. Prolonged inflation- ( up to 10 min) of an oversized balloon at low pressure. Reversal of anticoagulation pericardiocentesis Coils, Covered stents (require post-dilation, high pressure) Javaid et al Am J Cardiol 2006; 98: 911-4

34 Preventive Measures Make sure – indication for PCI
Watch the tip of the guide wire Sizing of the device( small vessel, tortuous , Bend points) During CTO: (confirm the distal end of balloon). Undersize- CB, ROTO, ( Bends) Do not oversize Stent ( small vessels)-do simple balloon or leave them alone- ALWAYS CHECK ANGIO, before removing stent balloon– if you see—just inflate the same balloon

35 Standby CPS for Elective Interventions
Total Number of Interventions at Washington Adventist Hospital from 4/1988 to 2/2000 N = 23,472 Refractory Cardiopulmonary Arrest in the cath lab N=39 (0.2%) Abrupt closure N=26* *(no reflow in 8 & air E in one) Perforation N=7 LM dissection N=5 Pulmonary edema N=1 Surgery N=10 Survived N=7 Expired N=3 Re-intervention N=29 Survived N=24 Expired N=5 Shawl, et al., J ACC 2001( Abs.)

36 Standby CPS for Elective Interventions
Cardiopulmonary Arrest (Imminent death) Overall survival Percutaneous interventions Emergency surgery 39 (0.2%) 31/39 (79%) 24/29 (83%) 7/10 (70%)

37

38 74 yr. old male – NSTMI – PCI to mid LAD

39

40

41

42

43

44

45

46

47

48

49


Download ppt "Cath Lab Catastrophes : Prevention & Management Strategies"

Similar presentations


Ads by Google