Introduction; iMCB a safety monitoring and energy management system, with smart disconnect features. It has a short circuit protection, leakage protection,

Similar presentations


Presentation on theme: "Introduction; iMCB a safety monitoring and energy management system, with smart disconnect features. It has a short circuit protection, leakage protection,"— Presentation transcript:

1 Introduction; iMCB a safety monitoring and energy management system, with smart disconnect features.
It has a short circuit protection, leakage protection, overload, over current, under voltage, over voltage protection Energy usage reference. Mainly combined with Smart intelligent energy usage safety and management platform, apply normal energy characteristic, failure analyse and statistic information for central database management.

2 2P iMCB Optional F10 (10A), F16 (16A),
F20 (20A), F25 (25A), F32 (32A), F40 (40A). F63 (63A). 1P+N Leakage Protection iMCB Z32 (32A), Z63 (63A) P25 T20

3 iMCB Advantage High Safety Standard; iMCB Intelligent Master Circuit Breaker, with basic MCB short circuit, leakage protection, plus improved overload, over current accurate, added under voltage and over voltage protection, energy usage and trend data. If Circuit Breaker is OFF, manual switch is available, Intelligent leakage and short circuit protection are still active. Short Circuit Protection Trip within 40ms. Prevent fire and further damage. Leakage protection: leakage 30ma, Trip at 100ms, human safety. Over Current(Over Load) Protection;10 sec. delay trip after 5% overload, 5 sec. delay trip after 35% overload, 1 sec. delay trip after 100% overload. Over Voltage (Under Voltage) Protection; Over Voltage 250V alarm warning, trip at 260V or over, under voltage alarm warning at 190V or lower. Spark protection; Trip if spark occurred. High Temperature Protection; Trip if temperature rise to 90 degree C. Surge Protection; Build in Power Supply surge protection up to 15KA. Current High Limit Set; user can customize high current within set limited, 5 sec delay trip if high current reached. Schedule Automatic Leakage Self Test; Monthly schedule available. Real Time Auto and Manual Control; Mobile remote, local push button and manual switch are available.

4 iMCB FEATURES ADVENTAGE OVER TRADITION CIRCUIT BREAKER (1)
Item Feature Range Tradition Circuit Breaker iMCB 1 Short Circuit Protection 5-10 set current, trip at 0.04 sec. Yes, fuse or Trip type, low quality product might failed Yes, using static sensor with silver contact, high quality material and construction. 2 Leakage Protection 30mA current leakage, trip at 0.1 sec. Yes, require high quality Leakage PCBA design, material and construction, risk on cheap brand name. Yes, constructed by professional current leakage sensor, reliable, still operate after circuit breaker Open. 3 Over Load/Current Protection Yes, reliability depends on the loading plate consistance, not accurate Yes, it sensed by electronic, very accurate 4 Low Voltage Alarm below 100Vac NO 5 Over Voltage Protection Yes, Alarm above 250Vac, trip or cut off at 263Vac 6 Spark Trip Protection Spark on connection, Trip Yes, Trip if spark 10 times within 5 seconds 7 Circuit Over heat Protection Real time circuit breaker Temperature Monitoring Yes, Alarm at 70 degree C, Trip at 90 degree C. 8 Surge Protection YES 9 Local Manual Control ON or OFF Control 10 Local push button Control 11 Remote Mobile Control 12 Local Leakage Self Test Local Self Test Push Button Yes, monthly Self Test once a month by Law

5 iMCB FEATURES ADVENTAGE OVER TRADITION CIRCUIT BREAKER (2)
Item Feature Range Tradition Circuit Breaker iMCB 13 Mobile Leakage Self Test Moble Self Test Push Button NO YES 14 Leakage Automatic Self Test Schedule Self Test Configuration YES, Schedule Self Test if set up actived. 15 Circuit Breaker Automatic Recover Set up automatic self recover condition YES, Leakage Self Test, will recover in 5 second if internal circuit Self Test Passed. 16 Energy High Limit Trip on equal or over Energy High Limit Set Up Yes, monitor accurately below set up high limit 17 Operation Logger Operation Trip, Test or Alarm Logger Yes, 12 months log available 18 Moible APP Management 19 Property Management System 20 Energy Monitoring Energy Graphic Display 21 Votage and Current Monitoring Yes, real time monitoring availble. 22 Smart Home APP Interface Intergrate in Smart Home as internet of Thing Yes, allow two way commincation, monitoring and control 23 CCTV APP Interface Yes, a selection of Camera available. 24 Central Management Platform vs internet or VPN Yes, Building Energy Management, Security Platform, Central Data Management

6

7 6 Channel Demo Box

8 8 Channel Demo Box

9

10

11

12 POWER SUPPLY MODULE P25 Application, Indoor usage, AC50Hz, 220Vac range, within 45C Environmental temperature, power supply for intelligent circuit breaker low voltage DC, and power surge protection. Normal working condition 2.1 Environmental temperature -5~45 Degree C 2.2 Installation location below 2000m 3. Product code description 4. Main features 12 DC with circuit breaker power supply, 15KA surge protection, maximum 15KA leakage current, 0.1 second trigger on 30ma trip protection.

13 SINGLE PHASE CIRCUIT BREAKER WITH LEAKAGE PROTECTION ,1P+N Z63
Indoor usage, 220V, operation below 45 C room temperature. Normal Operation Condition; 2.2 environmental temperature -5 ~45 C 3. Function as current leakage when over 30mA, provide 0.1 second Trip protection. 3.1 Short circuit protection, power shortage, circuit breaker trip at 0.04 second protection. 4. Protection; 4.1 Over voltage protection: input over 260V, trip at less than 10 seconds, warning over 250V, and lower than 190V. 4.2 Sparkling Protection; terminal wire and connector sparkling, trip protection. 4.3 Lightening Protection; maximum current suppression at 15KA 4.4 Over Current Limitation; tripped after 5 seconds 4.5 Automatic Leakage self test; optional monthly self tested. 4.6 Automatic recover on leakage protection after 5 seconds 4.7 Manual Automatic Control in one module; mobile phone remote, push button switch, or leverage control.

14 SINGLE PHASE CIRCUIT BREAKER, 2P with leakage protection F32
Indoor usage, 220V, operation below 45 C room temperature. Normal Operation Condition; 2.2 environmental temperature -5 ~45 C 3. Function as current leakage when over 30mA, provide 0.1 second Trip protection. 3.1 Short circuit protection, power shortage, circuit breaker trip at 0.04 second protection. 4. Protection; 4.1 Over voltage protection: input over 260V, trip at less than 10 seconds, warning over 250V, and lower than 190V. 4.2 Sparkling Protection; terminal wire and connector sparkling, trip protection. 4.3 Lightening Protection; maximum current suppression at 15KA 4.4 Over Current Limitation; tripped after 5 seconds 4.5 Automatic Leakage self test; optional monthly self tested. 4.6 Automatic recover on leakage protection after 5 seconds 4.7 Manual Automatic Control in one module; mobile phone remote, push button switch, or leverage control.

15 SINGLE PHASE CIRCUIT BREAKER , 2P with leakage protection F20
Indoor usage, 220V, operation below 45 C room temperature. Normal Operation Condition; 2.2 environmental temperature -5 ~45 C 3. Function as current leakage when over 30mA, provide 0.1 second Trip protection. 3.1 Short circuit protection, power shortage, circuit breaker trip at 0.04 second protection. 4. Protection; 4.1 Over voltage protection: input over 260V, trip at less than 10 seconds, warning over 250V, and lower than 190V. 4.2 Sparkling Protection; terminal wire and connector sparkling, trip protection. 4.3 Lightening Protection; maximum current suppression at 15KA 4.4 Over Current Limitation; tripped after 5 seconds 4.5 Automatic Leakage self test; optional monthly self tested. 4.6 Automatic recover on leakage protection after 5 seconds 4.7 Manual Automatic Control in one module; mobile phone remote, push button switch, or leverage control.

16 SINGLE PHASE CIRCUIT BREAKER ,2P with leakage protection T32
Indoor usage, 220V, operation below 45 C room temperature. Normal Operation Condition; 2.2 environmental temperature -5 ~45 C 3. Function as current leakage when over 30mA, provide 0.1 second Trip protection. 3.1 Short circuit protection, power shortage, circuit breaker trip at 0.04 second protection. 4. Protection; 4.1 Over voltage protection: input over 260V, trip at less than 10 seconds, warning over 250V, and lower than 190V. 4.2 Sparkling Protection; terminal wire and connector sparkling, trip protection. 4.3 Lightening Protection; maximum current suppression at 15KA 4.4 Over Current Limitation; tripped after 5 seconds 4.5 Automatic Leakage self test; optional monthly self tested. 4.6 Automatic recover on leakage protection after 5 seconds 4.7 Manual Automatic Control in one module; mobile phone remote, push button switch, or leverage control.

17 SMART SERVER T20 SMART SERVER T20
Application, Indoor usage, within 45C Environmental temperature, provide intelligent Network for circuit breaker control. Normal working condition 2.1 Environmental temperature -5~45 Degree C 2.2 Installation location below 2000m 3. Product code description 4. Main features It’s connectivity features are including Hot spot Control, wireless WIFI access, wire IP45 internet cable, UART serial port communication, data analyze and storage.

18 http://www.snd02.com/pages/login.shtml Demo User Name: gj001
Demo Password: gj123456

19 System Alarm View System Alarm by select Building Block, year, month filter.

20 View System Voltage Data
Select “Voltage Status”. System display last 24 hours voltage usage curse, value be will display if mouse pointer at any data point. Voltage Status report must select by “Block”, “Year”, “Month” condition, then system will display as above condition, value be will display if mouse pointer at any data point.

21 Load Profile Date Report
5. Load Profile Report Select “Load Profile”. System report must select by “Block”, “Year”, “Month”, “Date” condition, then system will display 24 hours data as above condition, individual value be will display if mouse pointer at any data point.

22 Monthly Energy Loading Report
System report must select by “Block”, “Year”, “Month” condition, then system will display selected month data as above condition, individual value be will display if mouse pointer at any data point.

23 List All User Monthly Report
5. List All User Energy Report System report must select by “Block”, “Year”, “Month” condition, then system will display selected month data as above condition in User name, total usage by list.

24

25 GB (S208-F32) GB (S208-Z63) CCC CE certified LVD, EMC, R&TTE IEC or EN?

26 Mobile Phone Smart Operate System

27 Design limitation Leakage protection Z63, Z32
T20 Smart Terminal maximum=24 channel P25 Power Supply and inpluse module Maximum 8 channel 6 pin with casade power supply.. 5 pin with without power supply.. CE certified

28 Technical Specification
meter pull per minutes. I min data pull by ftp or web interface Minimum detectable load for iMCB Server address set at factory or by customer Data handle by user manual Motor pull live test What are the operation temperature

29 T20 reading 100msec per meter, yesterday i was showing 8 plus 1 meter, one cycle was 900msec. data collected in T20 and upload to server every 10 minutes automatic. If you read and control by mobile APPs, it is real time control.. ------ Please confirm if this is done by manual export or can it it be automated by API and/or FTP. If you use Apps pulling, it can be real time, T20 pull every 10 min. or you can FTP retrieve from their server. ---- - what is the minimum detectable load for the MCB Minimum display is 1W for master meter, channel meter minimum 2-3W. --- - can the address for the web server be set by the user or does it need to be done at the manufacturing stage It need to be done at the factory, i will clarify more details later. if the web server is done by the user, do you have documentation that explain how data is handled (format, API, security...) More details later.

30 ---- - what is the rated number of cycle for the motor under no load conditions and at full load
??? please clarify the question again? ---- (any design features to prevent arcing and sparks) Sparks detection: 10 sparks less than 5 seconds, it will trigger the trip protection. --- - what is the operating temperature range? refer to GB 10902,, operation temperature -5 to 40 degree C, it actually can operate at a wider range.

31 2018 February, 3 Phase will be released