1 ULTRASONIC TESTING OF RAIL
SANJEEV KUMAR RATHORE S.S.E/(PWAY)/USFD/DHG Div:ahmedabad WESTERN RAILWAY 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

2 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG
AREA CVERED BY70°PROBE 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

3 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG
SRT&DRT ON INDIAN RAILWAY ,FLAW DTECTION BY ULTRASONICS IS CARRIED OUT WITH THE HELP OF TWO DIFFERENT TYPES OF EQUIPMENTS VIZ SINGLE RAIL TESTER AND DOUBLE RAIL TESTER, SRT IS UTILISED ON INDIAN RAILWAY FOR 40 YEARS & DRT IS RECENT ORIGIN TEN YEARS BACK. IN ADDDITIONAL HAND TESTERS OF SOME DESIGNS ARE ALSO BEING USED PROCUREMENT OF USFD EQUIPMENTS SHOULD BE DONE ONLY FROM THE RDSO APPROVED SOURCES 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

4 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG
SINGLE RAIL TESTER SINGLE RAIL TESTER IS CAPABLE OF TESTING ONLY ONE OF THE RAILS AT A T IME AND IS PROVIDED WITH SEVEN PROBE O°,70°CENTRAL FORWARD(CF),70°CENTRAL BACKWARD(CB), 70 °GAUGE FACE FORWARD (GF),70°GAUGE FACE BACKWARD(GB) 70°NONGAUGE FACE FORWARD(NGF), AND 70°NON-GAUGE FACE BACKWARD(NGB) THE NORMAL PROBE IS DETECTING HORIZONTAL DEFECTS IN THE RAIL HEAD,WEB AND FOOT 70°PROBE IS FOR DETECTING TRANSVERSE DEFECT IN HEAD THE SIGNAL RECEIVED FROM THE DEFECTS BY ANY OF THE ABOVE PROBE IS INDICATED ON THE SCREEN,IN ORDER TO FIND OUT THE ORIGIN OF DETECTION 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

5 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG
DOUBLE RAIL TESTER THE DOUBLE RAIL TESTER IS CAPABLE OF TESTING BOTH RAILS AT A TIME. FOR EACH RAIL, SEVEN PROBES HAVE BEEN PROVIDED 0°;70°CENTRAL FORWARD(CF) ,70°CENTRAL BACKWARD(CB), 70 °GAUGE FACE FORWARD (GF), 70°GAUGE FACE BACKWARD(GB) 70°NONGAUGE FACE FORWARD(NGF), AND 70°NON-GAUGE FACE BACKWARD(NGB) THE NORMAL PROBE IS DETECTING HORIZONTAL DEFECTS IN THE RAIL HEAD,WEB AND FOOT 70°PROBE IS FOR DETECTING TRANSVERSE DEFECT IN HEAD THE SIGNAL RECEIVED FROM THE DEFECTS BY ANY OF THE ABOVE PROBE IS INDICATED ON THE SCREEN,IN ORDER TO FIND OUT THE ORIGIN OF DETECTION 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

6 DETAILS OF FREQUENCY &PROBES
TYPE FREQUENCY PROBE RIG SRT DRT NORMAL 4MHZ ONE ONE FOR EACH RAIL 70 CENTRAL 2MHZ TWO(F+B) TWO(F+B) FOR EACH RAIL 70GAUGEFACE 70 NONFAUG FACE TWO 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

7 CALIBRATION&SENSITIVITY SETTING
70°CENTRAL PROBE(F&B) PROBE DIA=20X20 FREQUENCY=2MHZ MODE=T+R RANGE=165 CALIBRATION=ON IIW BLOCK IST PEAK=6.06 CALIBRATION CHECKING=ON IIW BLOCK 25M.M. CURVE ,READ DEPTH= 25M.M. SENSITIVITY=ON SENSITIVITY BLOCK 12 M.M. DIA HOLE F.S.H.=60% HEIGHT REMARK=ADD 10DB GAIN ON SINGLE LINE& D- MARKED RAIL ON DOUBLE/MULTIPLE LINE 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

8 CLASSIFICATION OF RAIL DEFECT (70°-CENTRAL) -1
IN TUNNEL &APP., ON MAJOR BRIDGES,APPROACHES(100MM) IN THE VICINITY OF HOLES NEAR THE WELD X..H>30% V> 20% =IMR 30%≤H≤100% V<20% =O OTHER THAN LOCATION H> 50%,V> 60%=IMR H> 50%,60%>V> 20%=OBS 50%>H> 30%,V> 20%=OBS 30%≤H≤100%, V<20% =O 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

9 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG
CLASSIFFICATION OF RAIL DEFECTS(70°-CENTRAL) S/L-D MARKED-RAILS(10DB)-2 VUL. LOCATION 0%≤H≤100%,20%≤V≤100%=IMR OTHER LOCATION 50%≤H≤100%,20%≤V≤100%=IMR 0%≤H<50%,20%≤V≤100%=OBS 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

10 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG
WELD DEFECTS(AT+FB) PROBE USED NATURE OF DEFECT CLASSIFICATION 70°CENTRAL PROBE ANY TRANSVERSE DEFECT IN THE RAIL HEAD AT THE FOLLOWING LOCATION 1.IN TUNNEL &APP (100M) 2.ON BRIDGE APPROACHES(100MM) 3. IN THE VICINITY OF HOLES NEAR THE WELD (50MM FOR OLD WELD AND 75MM FOR NEW AT WELDFROM THE CENTRE OF WELD ON EITHER SIDE H ≥30%,V≥30% =IMRW ANY TRANSEVERSE DEFECT IN THE RAIL AT TRACK LOCATION OTHER THAN (A) H≥50%,V≥50% H≥50%,60%>V≥20% =OBSW 50%>H≥30%,V≥30% 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

11 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG
70° GFC&NGC(F&B) PROBE DIA=20X20 FREQUENCY=2MHZ MODE=T+R VELOCITY=3230M/S RANGE=165 CALIBRATION=ON IIW BLOCK IST PEAK=6.06 CALIBRATION CHECKING=ON IIW BLOCK 25M.M. CURVE SHOW DEPTH=25M.M. SENSITIVITY=ON SENSITIVITY BLOCK ,SET 5MM DIA HOLE FSH=60% FULL SCEEN HEIGHT 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

12 CLASSIFICATION OF RAIL DEFECTS 70°GF/NGF
IN TUNNEL&APP.,ON MAJOR BRIDGE&APPROACHES(100MM) VICINITY OF HOLESNEAR THE WELD H> 15%,V> 20%=IMR H> 15%,V<20%=O OTHER LOCATION H≥30%,V≥60%=IMR H≥30%,60%>V≥20%=OBS 30%>H≥15%,V≥20%=OBS H≥15%,V<20%=O 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

13 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG
WELD DEFECTS(AT+FB) PROBE USED NATURE OF DEFECT CLASSIFICATION 70°GF/NGF PROBE ANY TRANSVERSE DEFECT IN THE RAIL HEAD ON GF/NGF AT THE FOLLOWING LOCATION 1.IN TUNNEL &APP (100M) 2.ON BRIDGE APPROACHES(100MM) 3. IN THE VICINITY OF HOLES NEAR THE WELD (50MM FOR OLD WELD AND 75MM FOR NEW AT WELDFROM THE CENTRE OF WELD ON EITHER SIDE H ≥15%,V≥20% =IMRW ANY TRANSEVERSE DEFECT IN THE RAILHEADONGF/NGF SIDE AT TRACK LOCATION OTHER THAN (A) H≥30%,V≥60% H≥30%,20%≤V<60% =OBSW 15%≤H≥30%,V≥20% 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

14 SENSITIVITY SETTING BLOCK TOP-VIEW
11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

15 SENSITIVITY SETTING BLOCK SIDE VIEW
11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

16 SENSITIVITY SETTING BLOCK (END VIEV)
11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

17 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG
ACTION TO BE TAKEN AFTER DETECTION OF DEFECTS CLASSIFICATION PAINTING ON BOTH FACES OF WEB ACTION TO BE TAKEN INTERIM ACTION IMR/IMRW THREE CROSS WITH RED PAINT THE DEFECTIVE PORTION SHOULD BE REPLACED BY A SOUND TESTED RAIL PIECE OF NOT LESS THAN 5.5M LENGTH( IN CASE OF FISH PLATED TRACK)&4M LENGTH ( IN CASE OF WELDED TRACK) WITHIN 3DAYS OF DETECTION SSE/JE/USFD SHALL IMPOSE SPEED RESTRICTINOF 30KMPH IMMEDIATELY T AND TO BE CONTINUED TILL FLAWEDRAIL/WELD IS REPLACED. HE SHOULD COMMUNICATE TO SECTIONAL JE/PWAY ABOUT THE FLAW LOCATION WHO SHALL ENSURE THAT CLAMPED JOGGLED FISHPLATEIS PROVIDEDWIHIN 24HRS OBS/OBSW ONE CROSS WITH RED PAINT RAIL/ WELD TO BE PROVIDED WITH CLAMPED JOGGLED FISHPLATE WIHIN 3 DAYS.SSEE/JE/PWAY/USFD TO SPECIALLY RECORD THE OBSERVATION OF THE LOCATION IN HIS REGISTER & CHECK IN NEXT TESTING ROUND SSE/JE/PWAY/ USFD TO ADVICE SECTIONAL JE/PWAY FOR PROVIDING JOGGLED FISHPLATE WITHIN 24HRS. KEYMAN WATCH DURING DAILY THAT LOCATION TILL IT IS JOGGLED 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

18 FREQUENCY OF TESTING (ALL MAIN LINE B.G.&M.G.)
ROUTE ROUTE HAVING GMT TESTING FREQUENCY(ONCE IN) ALL MG ROUTE <2.5 5YEARS 3YEARS >5 2YEARS ALL BG ROUTE ROUTES (Rail Head Centre And Gauge Face Corner Testing ≤5 >5≤8 12 MONTH >8≤12 9MONTH >12≤16 6MONTH >16≤24 4MONTH >24≤40 3MONTH >40≤60 2MONTH >60≤80 1 -1/2MONTH >80 1MONTH 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

19 TH.&GFC TESTING OF RAIL (SOME IMPORTANT FACTS)
1.VISUAL INSPECTION OF EQUIPMENT AND ACCESSORIES-DAILY CHECK 2.CALIBRATION OF EQUIPMENT= ONCE A WEEK 3.SENSITIVITY SETTING OF THE EQUIPMENT AND PROBE= ONCE EVERY 3DAYS(CS-3) 4.CHECKING OF EQUIPMENT CHARACTERISTICS=MONTHLY CHECK 5.TESTING ON SINGLE LINE SECTION AND “D” MARKED RAILS ON DOUBLE /MULTIPLE LINE SECTION. ADITIONAL 10DB GAIN IN 70° CENTRAL PROBE IS TO BE EMPLOYED. 6.. ADITIONAL OF 10DB GAIN IS NOT TO BE EMPLOED FOR CLASSIFICATION OF DEFECT IN WELD HEAD. 7.DEFECT AT ANY LOCATION WHICH IS DETECTED BY TWO OR MORE PROBE AND ARE CONSIDERED TO BE CLASSIFIED AS OBS/OBSW BASE ON PEAK PATTERN OF INDIVVSUAL PROBE SHOULD BE CLASSIFIED IMR /IMRW-CS-3 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

20 TH.&GFC TESTING OF RAIL (SOME IMPORTANT FACTS)
7. IN CASE OF TWO OR MORE OBS/OBSW DEFECT ARE LOCATED WITHIN A DISTANCE OF 4.0 MTRE FROM EACH OTHER . SUCH OBS/OBSW DEFECTS SHALL BE CLASSIFIED AS IMR/IMRW-CS-3 8.SENSITIVITY SETTING BLOCK SHOULD BE LENGTH OF 1.5 MTRE-CS-3 9..ANY SWEEPING SIGNAL ON HORIZONTAL BASE LINE THAT DOES NOT EXTEND BEYOND2.5 DIVISION FROM THE LEFT EDGE OF THE SCREEN SHALL BE RECORDED AS GAUGE CORNER CRACKING (GCC) AND NOT OBS CODE DESCRIPTION TRANVERSE FLAW IN HEAD TRANSVERSE CRACK IN FLUSH BUTT JOINT HORIZONTAL CRACK IN FLUSH BUTT JOINT TRANSVERSE CRACK IN I AT WELD HORIZONTAL CRACK IN AT WELD 11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG

21 CALIBRATION BLOCK IIW(VI)
11/9/2018 PRESENTED BY SANJEEV RATHORE S.S.E.(PWAY)/USFD/DHG