Presentation is loading. Please wait.

Presentation is loading. Please wait.

Empirical Attenuation Factors Predictions & Observational Data

Similar presentations


Presentation on theme: "Empirical Attenuation Factors Predictions & Observational Data"— Presentation transcript:

1 Empirical Attenuation Factors Predictions & Observational Data
Helen Dawson, Ph.D. US EPA Region VIII Denver, CO Ian Hers, Ph.D. Golder Associates Vancouver, BC, Canada Robert Truesdale RTI International RTP, North Carolina

2 Empirical Attenuation Factors
Evaluations (Helen Dawson) 2004 Evaluations (Ian Hers) Future Evaluations (Robert Truesdale)

3 Measured Attenuation Factors 2001-2002 Database Summary
15 sites, 15 VOCs, 274 total residence/chemical combinations 35 BTEX; 239 CHC residence/chemical combinations 99 sites with IA > 10-6 IA RBC (84 CHC, 14 BTEX) 68 sites with IA > 10-5 IA RBC

4 2001 – 2002 Empirical Attenuation Factors Groundwater-to-Indoor Air
All residences and chemicals with concentrations above MDLs

5 Factors evaluated (2001 – 2002) Chemical type Foundation type
Soil type Depth to source

6 2001 – 2002 Empirical Attenuation Factors Chlorinated Hydrocarbons vs
2001 – 2002 Empirical Attenuation Factors Chlorinated Hydrocarbons vs. BTEX

7 2001 – 2002 Empirical Attenuation Factors Influence of Foundation Structure?
Groundwater

8 2001 – 2002 Empirical Attenuation Factors Influence of Foundation Structure?

9 2001 – 2002 Empirical Attenuation Factors Influence of Soil Type?

10 2001 – 2002 Empirical Attenuation Factors Depth to Groundwater?

11 2001 – 2002 Empirical Attenuation Factors Conclusions
Measured attenuation factors range from 10-2 to 10-7 with median values around 10-4. Influence of foundation type, soil type, and depth to water on the empirical attenuation factors is unclear. Higher ranges of attenuation factors are observed for BTEX compounds; median value is around 10-5.


Download ppt "Empirical Attenuation Factors Predictions & Observational Data"

Similar presentations


Ads by Google