Presentation is loading. Please wait.

Presentation is loading. Please wait.

THE VOLUMETRIC MASS TRANSFER COEFFICIENT kLa AND METHODS OF

Similar presentations


Presentation on theme: "THE VOLUMETRIC MASS TRANSFER COEFFICIENT kLa AND METHODS OF"— Presentation transcript:

1 THE VOLUMETRIC MASS TRANSFER COEFFICIENT kLa AND METHODS OF
THE VOLUMETRIC MASS TRANSFER COEFFICIENT kLa AND METHODS OF MEASUREMENT

2 Mass Balance of Oxygen in Unit Liquid Volume
FIG. 2.7 Schematic diagram of the mass balance of oxygen transfer in unit liquid volume

3 Mass Balance of Oxygen in Unit Liquid Volume (Cont’d)

4 Mass Balance of Oxygen in Unit Liquid Volume (Cont’d)

5 Mass Balance of Oxygen in Unit Liquid Volume (Cont’d)

6 Mass Balance of Oxygen in Unit Liquid Volume (Cont’d)

7 Mass Balance of Oxygen in Unit Liquid Volume (Cont’d)

8 Methods of Measurement of KLa in a Bioreactor

9 Chemical Methods of KLa Measurement
FIG Schematic diagram of a stirred tank batch reactor

10 In Situ Measurement of KLa, QO2, and CL
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor

11 In Situ Measurement of KLa, QO2, and CL
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor (Cont’d) The Bioreactor Vessel is Equipped with: ● The D.O. Probe, Connected to a D.O. Analyzer. ● Chart Recorder: To Measure Signal from D.O. Probe and Measure On-line the D.O. Concentration in the liquid phase of the Bioreactor.

12 In Situ Measurement of KLa, QO2, and CL
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor (Cont’d) ● The D.O. Probe Measures the PyO2 Partial Pressure (PyO2) of dissolved O2 in the liquid phase, which means that it measures HO2CL. Where: HO2 = Henry’s Constant for O2 in Water CL = D.O. Concentration In the Liquid Phase (Mass of O2/L)

13 In Situ Measurement of KLa, QO2, and CL
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor (Cont’d) Fig Set up of a Stirred tank Bioreactor with Dissolved Oxygen Probe, pH probe and accessories.

14 ● Turning air ON and OFF while Maintaining the same R.P.M. we can:
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor (Cont’d) ● Turning air ON and OFF while Maintaining the same R.P.M. we can: Record the D.O. Probe Output in the Chart Recorder. From these Data, we can get KLa, QO2, CL* at given in-situ Bioreactor Conditions.

15 ● The ON-OFF Operation takes 5 min, during which time:
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor (Cont’d) ● The ON-OFF Operation takes 5 min, during which time: Cell Concentration X (g /L)  Constant. We make sure that the D.O. Concentration CL never falls below the critical oxygen concentration CCRT, which means that the respiration rate coefficient QO2 = QO2Max = Constant. ● Using the D.O. probe output and a recorder we measure directly the D.O. concentration as a function of time, t.

16 In Situ Measurement of KLa, QO2, and CL
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor While we maintain the same R.P.M. of the bioreactor impeller, we turn the AIR-OFF. During the AIR-OFF period the following conditions apply: ● Rate of Supply of O2 = 0 ● No Air Present in the Bioreactor ● KLa = 0 because a = 0, no air bubbles present ● Using Eq. 2.2 for O2 Mass Balance, we have: ● We know cell concentration X by measuring it. Therefore, we calculate QO2 because we also measure the slope – QO2X.

17 In Situ Measurement of KLa, QO2, and CL
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor ● Fig.1 Shows D.O. concentration CL inside the bioreactor = f(t) when Air is turned Off and On, always keeping the R.P.M. of the impeller the same to provide good mixing of the liquid phase. ● After a period of about 5 min, a liquid sample is taken from the bioreactor to measure the cell concentration X (g dry wt./L). ● The KLa, QO2, and CL* values correspond to that specific fermentation time and given cell growth conditions. ● We can do many AIR-OFF and AIR-ON measurements to get all three parameters KLa, QO2, and CL* as a function of total batch fermentation time.

18 In Situ Measurement of KLa, QO2, and CL
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor FIG.1 Transient Air-Off, Air-On Experiment in a Bioreactor System

19 In Situ Measurement of KLa, QO2, and CL
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor ● During the AIR-OFF period the D.O. concentration CL is plotted as a function of time t from which we get the slope = - QO2X, as shown in Fig. 2. FIG. 2 D.O. concentration CL as function of time during AIR-OFF period.

20  From the CL vs. time (t) data we can get
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor  AIR-ON Period During this period the following oxygen mass balance equation applies:  From the CL vs. time (t) data we can get

21 In Situ Measurement of KLa, QO2, and CL
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor ● Re-arranging Eq. 2.2 and solving for CL we get Eq. 2.9 ● By plotting CL vs at a given fermentation time, t, we can get the slope which is equal to

22 In Situ Measurement of KLa, QO2, and CL
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor (Cont’d) ● and therefore, the value of KLa is found, and the intercept also gives the value of ● During the Air-On Period: CL* = Constant QO2 = Constant KLa = Constant CL, dCL/dt vary with time t

23 In Situ Measurement of KLa, QO2, and CL
In Situ Measurement of KLa, QO2, and CL* During Cell Growth in a Bioreactor FIG D.O. concentration CL as function of [dCL/dt + QO2X] during AIR-ON period.

24 GENERALIZED VIEW OF BIOPROCESS

25 TYPICAL BIOPROCESS FLOW SHEET


Download ppt "THE VOLUMETRIC MASS TRANSFER COEFFICIENT kLa AND METHODS OF"

Similar presentations


Ads by Google