Presentation is loading. Please wait.

Presentation is loading. Please wait.

Kane County Energy Plan Update

Similar presentations


Presentation on theme: "Kane County Energy Plan Update"— Presentation transcript:

1 Kane County Energy Plan Update
Strategies Presentation to the Energy and Environmental Committee of the Kane County Board Lindy Wordlaw CNT Energy August 18, 2010

2 Goal for Today: Strategy Basics
Description of strategy Expected annual energy/cost savings per unit Feasibility at countywide implementation Expected annual energy/cost savings countywide Feedback and questions

3 Quick Recap Energy Consumption in Kane County 2040 Energy Forecast

4 Kane County Energy Use (2008)
 Natural Gas 2008 Residential 181,639,334 C&I 158,437,043 Total 340,076,377

5 Kane County Energy Use (2008)
 Natural Gas 2008 Residential 181,639,334 C&I 158,437,043 Total 340,076,377 Electricity  kWh Residential 1,617,248,849 C&I 3,253,629,099 Total 4,870,877,948

6 Average account consumption
2008 Average Consumption/Cost1 Natural gas (in therms) Electricity (in kWh) Residential 1,107 ($1,124) 9,858 ($1,141) C&I 10,941 ($14,237)2 87,266 ($8,295)2 1 Illinois Commerce Commission Electricity and Natural Gas Sales Statistics, 2008 2 Blended rate between Small and Large commercial rates

7 Forecast to 2040 – Business as usual
Residential C&I Electricity (kWh) Gas (therms) 2008 consumption 1,617,248,849 181,639,334 3,253,629,099 158,437,043 Growth factor 1 0.49% -0.57% 0.44% 0.24% Projected 2040 consumption 1,889,025,035 151,285,016 3,747,267,064 170,904,954 1 From the 2010 EIA Annual Energy Outlook -

8 C&I Natural Gas Accounts
Projected Growth 2040 2008 Households 274,085 1 164,060 3 C&I Electric Accounts 62,288 2 37,284 4 C&I Natural Gas Accounts 34,596 2 14,481 5 Provided by Chicago Metropolitan Agency for Planning, GO TO 2040 Scaled based on current ratio of households and C&I accounts U.S. Census Bureau, American Community Survey 2008 ComEd Nicor

9 Types of Strategies Residential / Commercial & Industrial
Occupant energy use Building energy use Appliances and lighting Renewable energy (energy generation)

10 Types of Strategies Residential / Commercial & Industrial
Occupant energy use Building energy use Appliances and lighting Renewable energy (energy generation) REMINDER: Cost savings shown in 2009 prices (doesn’t account for price fluctuations) Countywide shown in aggressive implementation scenario for the year 2040 (not cumulative savings over time) Slide 10

11 Occupant Energy Use

12 Behavior Change (R) Heighten energy efficiency awareness
Simple EE things around the house

13 Behavior Change (R) Heighten energy efficiency awareness
Simple EE things around the house Increase/Decrease thermostat temperatures Reduce 6 light bulb hours/day Replace a/c filter Reduce phantom load Slide 13

14 Behavior Change (R) Heighten energy efficiency awareness
Simple EE things around the house Increase/Decrease thermostat temperatures Reduce 6 light bulb hours/day Replace a/c filter Reduce phantom load Strategy: Behavior Change (R) Targeted Corridor: Urban Renaissance; Critical Growth Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) 50 $34 Electricity (kWh) 674 $79 Total $103 50% HH in 2040 6,808,271 $4,694,984 92,433,741 $10,823,991 $15,518,975 Slide 14

15 Behavior Change (C&I) Increase/Decrease thermostat temperatures
Additional thermostat setback during non-working hours Strategy: Behavior Change (C&I) Targeted Corridor: Urban Renaissance; Critical Growth Per Acct in 2040 Energy Savings Cost Savings Natural Gas (therms) 677 $431 Electricity (kWh) 2060 $163 Total $594 10% Acct in 2040 2,341,388 $1,492,752 12,834,318 $1,016,478 $2,509,230

16 Ceiling Fans (R) For use with air conditioning
Assumes 3% savings per thermostat degree increase Assumes all housing units built since 1980 have fans Not enough data to calculate for use with space heating

17 Ceiling Fans (R) For use with air conditioning
Assumes 3% savings per thermostat degree increase Assumes all housing units built since 1980 have fans Not enough data to calculate for use with space heating Strategy: Ceiling Fans (R) Targeted Corridor: Urban Renaissance; Critical Growth Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) $0 Electricity (kWh) 66 $8 Total 30% HH in 2040 3,768,722 $441,317 Slide 17

18 Building Energy Use

19 Retrofitting Existing Buildings (R)
Whole-home approach Assumes 30% energy savings, based on research/practice Smaller implementation countywide assumed, due to cost (But largest potential for energy savings) Slide 19

20 Retrofitting Existing Buildings (R)
Whole-home approach Assumes 30% energy savings, based on research/practice Smaller implementation countywide assumed, due to cost (But largest potential for energy savings) Strategy: Retrofits (R) Targeted Corridor: Urban Renaissance Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) 166 $114 Electricity (kWh) 2,068 $203 Total $317 6% HH in 2040 2,723,309 $1,877,994 34,001,889 $3,981,621 $5,859,615

21 Retrofitting Existing Buildings (C&I)
Whole-building approach Assumes 30% energy savings, based on research/practice Smaller implementation countywide assumed, due to cost Funding opportunities in both sectors (But largest potential for energy savings) Strategy: Retrofits (C&I) Targeted Corridor: Urban Renaissance Per Acct in 2040 Energy Savings Cost Savings Natural Gas (therms) 1,482 $945 Electricity (kWh) 18,048 $1,429 Total $2,374 6% Acct in 2040 3,076,276 $1,961,280 67,450,807 $5,342,104 $7,303,384

22 About Energy Codes State adopted mandatory energy codes: IECC (International Energy Conservation Code) Commercial and residential Applies to -New construction -Renovation -Additions

23 About Energy Codes State adopted mandatory energy codes: IECC (International Energy Conservation Code) Commercial and residential Applies to -New construction -Renovation -Additions Does not apply to -Historic buildings -Buildings not covered by code -buildings not using electricity/fossil fuels for comfort conditioning

24 About Energy Codes State adopted mandatory energy codes: IECC (International Energy Conservation Code) Commercial and residential Applies to -New construction -Renovation -Additions Does not apply to -Historic buildings -Buildings not covered by code -buildings not using electricity/fossil fuels for comfort conditioning All municipalities must comply (no home rule) and/or can enact strong codes

25 About Energy Codes Are municipalities in Kane County aware?
Have they adopted the new code? Potential training/enforcement issues

26 About Energy Codes Estimated energy savings: 15% (Higher when going from no code at all) Strategy: Energy Code (R) Targeted Corridor: Urban Renaissance; Critical Growth Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) 83 $57 Electricity (kWh) 1,034 $121 Total $178 100% HH in 2040 9,110,070 $6,282,304 113,743,845 $13,319,404 $19,601,709

27 About Energy Codes Estimated energy savings: 15% (Higher when going from no code at all) Strategy: Energy Code (R) Targeted Corridor: Urban Renaissance; Critical Growth Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) 83 $57 Electricity (kWh) 1,034 $121 Total $178 100% HH in 2040 9,110,070 $6,282,304 113,743,845 $13,319,404 $19,601,709 Strategy: Energy Code (C&I) Targeted Corridor: Urban Renaissance; Critical Growth Per Acct in 2040 Energy Savings Cost Savings Natural Gas (therms) 741 $472 Electricity (kWh) 9,024 $715 Total $1,187 100% Acct in 2040 18,527,964 $11,812,503 225,636,096 $17,870,379 $29,682,882

28 Green Building for New Construction (R)
Green Building (e.g. LEED) = sustainable building approach Energy savings + water + materials + air quality, etc… Assumes 30% energy savings Trends show commercial sector as lead, then residential

29 Green Building for New Construction (R)
Green Building (e.g. LEED) = sustainable building approach Energy savings + water + materials + air quality, etc… Assumes 30% energy savings Trends show commercial sector as lead, then residential Strategy: Green Building (R) Targeted Corridor: Critical Growth Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) 166 $114 Electricity (kWh) 2,068 $242 Total $356 15% HH in 2040 2,733,021 $1,884,691 34,123,154 $3,995,821 $5,880,513 Slide 29

30 Green Building for New Construction (C&I)
Assumed much higher percentage for countywide implementation based on national trends Strategy: Green Building (C&I) Targeted Corridor: Critical Growth Per Acct in 2040 Energy Savings Cost Savings Natural Gas (therms) 1,482 $945 Electricity (kWh) 18,048 $1,429 Total $2,374 100% Acct in 2040 37,055,928 $23,625,007 451,272,192 $35,740,758 $59,365,765 Aurora Police Department Gail Borden Public Library, Elgin

31 Appliances and Lighting

32 Window Air Conditioner Replacement (R)
Assumes housing built before 1980 doesn’t have central air (approximately 91,000 housing units) Best strategies nationwide focus on replacement, not just providing efficient window air conditioners Utility programs Strategy: Window A/C Replacement (R) Targeted Corridor: Urban Renaissance Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) $0 Electricity (kWh) 221 $26 Total 10% HH in 2040 2,028,360 $237,521

33 Central Air Conditioner Replacement (R)
Replacement occurs only when previous system fails (lifespan years) Success increases over time through education + government requirements (e.g SEER) Utility programs Slide 33

34 Central Air Conditioner Replacement (R)
Replacement occurs only when previous system fails (lifespan years) Success increases over time through education + government requirements (e.g SEER) Utility programs Assumes housing built after 1980 does have central air Assumes replacement with 14.5 SEER (versus current standard) Strategy: Central A/C Replacement (R) Targeted Corridor: Urban Renaissance; Critical Growth Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) $0 Electricity (kWh) 467 $55 Total 10% HH in 2040 8,866,929 $1,038,317 Slide 34

35 Refrigerator Replacement (R)
Many homes have second refrigerators; target removal Best strategies nationwide focus on removal of old refrigerators (e.g. avoid the “beer fridge” effect) Upgrade occurs only when previous refrigerator fails Utility programs

36 Refrigerator Replacement (R)
Many homes have second refrigerators; target removal Best strategies nationwide focus on removal of old refrigerators (e.g. avoid the “beer fridge” effect) Upgrade occurs only when previous refrigerator fails Utility programs Strategy: Refrigerator Replacement (R) Targeted Corridor: Urban Renaissance; Critical Growth Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) $0 Electricity (kWh) 500 $59 Total 10% HH in 2040 13,704,250 $1,604,768 Slide 36

37 Refrigerator Replacement (R)
Many homes have second refrigerators; target removal Best strategies nationwide focus on removal of old refrigerators (e.g. avoid the “beer fridge” effect) Upgrade occurs only when previous refrigerator fails Utility programs Strategy: Refrigerator Replacement (R) Targeted Corridor: Urban Renaissance; Critical Growth Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) $0 Electricity (kWh) 500 $59 Total 10% HH in 2040 13,704,250 $1,604,768 Slide 37 FridgeHenge, public art in Santa Fe, NM

38 About Street Lights (C&I)
Huge savings potential for municipalities Efficient lights: Induction; LED Ownership issues (ComEd vs. Municipality) Billed by assumed daylight hours, and type of light/fixture Strategy assumptions: -155 watt light replaced with 55 watt induction light -10 hour/day burn time Strategy: Street Light Replacement (C&I) Targeted Corridor: Urban Renaissance; Critical Growth Per 100 Lights Energy Savings Cost Savings Natural Gas (therms) $0 Electricity (kWh) 43,800 $3,964 Total Over 20 Yrs. (Expected Lifetime of Lights) 876,000 $79,278 Per Municipality

39 About Traffic Lights (C&I)
Huge savings potential for municipalities (lights are on 24/7) Light Emitting Diode (LED) use 80-90% less energy Assumption: 150 watt light replaced by 25 watt light Expected lifetime 5-7 years vs. months Elgin replaced nearly all of their intersections Strategy: Traffic Light Replacement (C&I) Targeted Corridor: Urban Renaissance; Critical Growth Per Traffic Light Energy Consumption Cost STANDARD 8-LIGHT INTERSECTION 10,512 kWh $951 LED 8-LIGHT INTERSECTION 1,752 kWh $159 Over 5 Yrs. 52,560 kWh $4,757 8,760 $793 One Intersection!

40 Renewable Energy

41 On-site Renewable Energy (R)
Renewable energy uses sources other than fossil fuels Most viable in Illinois is wind and solar Renewable Energy Portfolio establishes legal requirements for electric utilities Assumptions: electricity; very low implementation due to cost (cheaper at time of construction)

42 On-site Renewable Energy (R)
Renewable energy uses sources other than fossil fuels Most viable in Illinois is wind and solar Renewable Energy Portfolio establishes legal requirements for electric utilities Assumptions: electricity; very low implementation due to cost (cheaper at time of construction) Assumptions: generates enough electricity to supply HH needs Strategy: On-site Renewable Energy (R) Targeted Corridor: Urban Renaissance; Critical Growth Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) $0 Electricity (kWh) 6,892 $807 Total 3% HH in 2040 56,669,815 $6,636,035

43 On-site Renewable Energy (R)
Renewable energy uses sources other than fossil fuels Most viable in Illinois is wind and solar Renewable Energy Portfolio establishes legal requirements for electric utilities Assumptions: electricity; very low implementation due to cost (cheaper at time of construction) Assumptions: generates enough electricity to supply HH needs Should strongly encourage connecting to the grid Strategy: On-site Renewable Energy (R) Targeted Corridor: Urban Renaissance; Critical Growth Per HH in 2040 Energy Savings Cost Savings Natural Gas (therms) $0 Electricity (kWh) 6,892 $807 Total 3% HH in 2040 56,669,815 $6,636,035

44 On-site Renewable Energy (C&I)
Assumptions: electricity; more viable for C&I sector than residential Assumptions: generates enough electricity to supply approximately half of the average business needs Strategy: On-site Renewable Energy (C&I) Targeted Corridor: Urban Renaissance; Critical Growth Per Acct in 2040 Energy Savings Cost Savings Natural Gas (therms) $0 Electricity (kWh) 30,080 $2,382 Total 30% Acct in 2040 562,086,912 $44,517,283

45 Distributed Generation and Combined Heat & Power (C&I)
What are they?

46 Distributed Generation and Combined Heat & Power (C&I)
What are they? Any technology that produces power outside of the utility grid. Here in Kane County: Sherman Hospital, Elgin Fox Metro Water Reclamation District, Aurora

47 Distributed Generation

48 Combined Heat and Power

49 Distributed Generation and Combined Heat & Power (C&I)
Additional benefits beyond renewable capabilities and decreasing reliance on fossil fuels: -Reliability -Security -Decrease in “line losses” Strategy: DG /CHP (C&I) Targeted Corridor: Urban Renaissance; Critical Growth Per Acct in 2040 Energy Savings Cost Savings Natural Gas (therms) TBD Electricity (kWh) Total TBD% Acct in 2040

50 Based on a mix of these strategies
What’s Next 1) Set of 2040 Energy Forecasts Business As Usual Aggressive (aggressive action towards increasing energy efficiency) Moderate (moderate action towards increasing energy efficiency) Conservative (Conservative, limited action towards increasing energy efficiency) Based on a mix of these strategies

51 Followed by Draft/Final Plan Writing County workshop

52 Questions Are there other strategies we should be addressing?
Questions on any calculations or assumptions? Additional feedback?

53 Thank you! Lindy Wordlaw, Senior Planner lindy@cntenergy.org
(773) Kimberly Loewen, Planner (773) Larry Kotewa, Engineer (773) Jessica Spanier, Data Analyst (773)


Download ppt "Kane County Energy Plan Update"