Measurement of static and dynamic compliance during mechanical ventilation. A tidal volume is delivered, causing a peak in airway pressure; dynamic compliance.

Similar presentations


Presentation on theme: "Measurement of static and dynamic compliance during mechanical ventilation. A tidal volume is delivered, causing a peak in airway pressure; dynamic compliance."— Presentation transcript:

1 Measurement of static and dynamic compliance during mechanical ventilation. A tidal volume is delivered, causing a peak in airway pressure; dynamic compliance is calculated at the peak inspiratory pressure (PIP). A short pause is applied before expiration to eliminate airway pressure caused by gas flow, and airway pressure decreases to a plateau (PPLAT). Static compliance is calculated during the plateau. A. Normal response. B. Low lung compliance causes a global increase in airway pressure and a decrease in both static and dynamic compliance. C. High airway resistance increases peak airway pressure but does not change the plateau pressure; dynamic compliance is decreased but static compliance is unchanged. Source: Pulmonary Physiology, Medical Physiology: The Big Picture Citation: Kibble JD, Halsey CR. Medical Physiology: The Big Picture; 2015 Available at: Accessed: January 03, 2018 Copyright © 2018 McGraw-Hill Education. All rights reserved


Download ppt "Measurement of static and dynamic compliance during mechanical ventilation. A tidal volume is delivered, causing a peak in airway pressure; dynamic compliance."