Presentation is loading. Please wait.

Presentation is loading. Please wait.

Analysis of niobium material

Similar presentations


Presentation on theme: "Analysis of niobium material"— Presentation transcript:

1 Analysis of niobium material
Konrad Eiler 22/02/2016

2 Contents Nb/Nb 3 mm circular weld by Niowave Metallography Hardness
Nb H8 from Heraeus Tensile tests Konrad Eiler

3 Circular weld Nb Specimen “R” Specimen “180˚” [1] Konrad Eiler

4 Circular weld Nb – metallography
Overlap region (recouvrement) Excessive weld metal Level B: ℎ≤0.65 mm [2] Thickness too low on one side – not related to welding Konrad Eiler

5 Circular weld Nb – metallography
180˚ Linear misalignment Level B: ℎ≤0.3 mm [2] Konrad Eiler

6 Circular weld Nb – hardness profile
Konrad Eiler

7 Circular weld Nb – Conclusions
Imperfections comply with acceptance level B of ISO Low local thickness of 2.5 mm not related to welding No increased hardness in weld pool Higher hardness in one sheet (ca. 80 HV10) Konrad Eiler

8 Nb H8 Heraeus – History [3]
Context: Nb rod from Heraeus, Ø133 mm x 635 mm For forming of beam port by Niowave Very low ductility and high yield strength Material was cold-worked and insufficiently annealed Rod has been sent back for re-annealing Konrad Eiler

9 Nb H8 Heraeus – Metallography
Recrystallisation into the former grains (before re- annealing) Higher degree of recrystallisation after re-anneal Still grains in the cm range in the centre Deformation bands visible Centre Outer radius Konrad Eiler

10 Nb H8 Heraeus – Tensile testing
Ductility improved, but too low Konrad Eiler

11 Nb H8 Heraeus – Hardness Vickers hardness through the rod's cross-section Very high deviation, inhomogeneous microstructure, highest hardness in the centre Konrad Eiler

12 Nb H8 Heraeus – Results Microstructure still not fully recrystallised
RT HV10 Rp0.2 [MPa] Rm [MPa] Ag [%] A [%] Samples 58 130 167 7.3 19.8 Spec [4] <60 50-100 >140 - >30 Microstructure still not fully recrystallised Tensile specimen taken from the same location broke at the same position Properties after re-annealing still not fulfilling the specification Ductility too low Konrad Eiler

13 References [1] ISO , Specification and qualification of welding procedures for metallic materials – Welding procedure test – Part 11: Electron and laser beam welding. ISO, [2] ISO , Welding – Electron and laser beam welded joints – Guidance on quality levels for imperfections – Part 2: Aluminium and its weldable alloys. ISO, [3] K. Eiler: Analysis of large grain size, low ductility niobium material. EDMS , [4] Technical Specification 3301: Pure niobium bars for superconducting applications (RRR 300 grade). EDMS , 2015. Konrad Eiler

14


Download ppt "Analysis of niobium material"

Similar presentations


Ads by Google