1 19th Catia/SmarTeam Users’ Forum
CATIA V5 R23 How does the Product Engineering Optimizer workbench can help you improving your design? HIE ISOLDE TUNER Virtual Pivot Concept 02/04/2015 19th Catia/SmarTeam Users’ Forum

2 19th Catia/SmarTeam Users’ Forum
HIE ISOLDE TUNER DEVICE OVERVIEW 02/04/2015 19th Catia/SmarTeam Users’ Forum

3 HIE Isolde QW cavity tuner
Niobium sputtered on bulk copper substrate 4.5 K, MHz, 6 MV/m , 10 W Coarse tuning done by mechanical trimming Requested fine tuning range 36 kHz, resolution 0.5 Hz Initial Cu-Be “oil can” shape design Costly sensitivity 11 kHz/mm Range 100 kHz higher than required Range of fine tuning range based on uncertainty frequency at cold during testing prototypes Flat plate design Machined to 0.3 mm in OFE copper + optimised tip gap Courtesy of : Kurt Artoos Walter Venturini Delsolaro

4 HIE Isolde QW cavity tuner
OFE Cu : improved temperature margin for Nb layer for power dissipated (L. Alberty) Drawback: mechanical stresses in the tuning plate, very local plastification during first cycle Not a problem Courtesy of : Kurt Artoos Walter Venturini Delsolaro

5 HIE Isolde QW cavity tuner
Motorization tuner outside cryostat for reliability and cost reasons Operation under traction (small range available in push, 0.6 mm at tuning plate) 1.8 Nm bi phase stepper motor with torque limiter at 1 Nm. Micro stepping 8000 steps/turn 1 mm pitch lubricated M6 Metric screw in bronze Measured resolution motor 0.1 to 0.2 µm Hysteresis under load : 1 to 2 µm Reliability feature: Motor completely exchangeable without Dismounting the cryomodule (includes possible exchange of vacuum passage pulling rod ) Courtesy of : Kurt Artoos Walter Venturini Delsolaro

6 HIE Isolde QW cavity tuner
Tuner lever system: Compact system Two levers with Ti double knife edge pivots Flexural link between two levers Divides motion + forces by factor 10 with very low friction Courtesy of : Kurt Artoos Walter Venturini Delsolaro

7 HIE Isolde QW cavity tuner
Courtesy of : Kurt Artoos Walter Venturini Delsolaro

8 19th Catia/SmarTeam Users’ Forum
HIE ISOLDE TUNER DEVICE OVERVIEW 02/04/2015 19th Catia/SmarTeam Users’ Forum

9 19th Catia/SmarTeam Users’ Forum
HIE ISOLDE TUNER DEVICE KINEMATIC 02/04/2015 19th Catia/SmarTeam Users’ Forum

10 19th Catia/SmarTeam Users’ Forum
STUDY INPUTS – KEY DATAS Stepping motor : 8000 steps/rotation Motor Stroke : +50mm / -6mm Tuning plate distortion : -5mm / +0,6mm Reduction ratio tuner stroke / motor stroke : 1/10 Very narrow space beneath the cavity Tuning range : Hz Tuning accuracy : +/- 0,5 Hz  Tuning plate theoretical resolution accuracy : +/- 40 nanometers !!! No stick/slip phenomenon allowed due to the requested resolution ! Necessity to use friction-free pivots + a virtual pivot due to the lack of space + resolution requirements 02/04/2015 19th Catia/SmarTeam Users’ Forum

11 19th Catia/SmarTeam Users’ Forum
HIE ISOLDE TUNER KINETIC SKELETON 02/04/2015 19th Catia/SmarTeam Users’ Forum

12 19th Catia/SmarTeam Users’ Forum
THE PRODUCT ENGINEERING OPTIMIZER WORKBENCH 02/04/2015 19th Catia/SmarTeam Users’ Forum

13 19th Catia/SmarTeam Users’ Forum
THE PRODUCT ENGINEERING OPTIMIZER WORKBENCH Driving parameter Driven parameter Target Value (imposed parameter) Optimization verification tool result Optimization rule Optimization automation tools 02/04/2015 19th Catia/SmarTeam Users’ Forum

14 19th Catia/SmarTeam Users’ Forum
THE PRODUCT ENGINEERING OPTIMIZER WORKBENCH 02/04/2015 19th Catia/SmarTeam Users’ Forum

15 HIE Isolde QW cavity tuner Results
Pei Zhang Small cycles hysteresis 100 cycles 3Hz Variation due to pressure change 0.08Hz/step Larger cycles hysteresis 0.6Hz 0.11Hz/step Courtesy of : Kurt Artoos Walter Venturini Delsolaro 15

16 HIE Isolde QW cavity tuner
Full tuner range 39 kHz Fatigue testing show no significant changes in behavior tuner Back lash when changing from pull to push due to change of contact in knife edge pivot (not expected operation situation) The hysteresis and resolution correspond to what was measured on the motor. This could be further reduced by using Planetary roller screws (not required for HIE ISOLDE) Coarse range 39 kHz Pull to push Courtesy of : Kurt Artoos Walter Venturini Delsolaro

17 19th Catia/SmarTeam Users’ Forum
THE PRODUCT ENGINEERING OPTIMIZER FAQ Need help to handle this powerful tool ? A dedicated FAQ is available on the CERN CAD Service website : CERN CAD Service / FAQ / CATIA - Knowledge & Optimizer / Optimization in CATIA 02/04/2015 19th Catia/SmarTeam Users’ Forum

18 19th Catia/SmarTeam Users’ Forum
SPECIAL THANKS !!! I would like to warmly thank M. Benoît Lepoittevin for the great support he has provided to me on the Product Engineering Optimizer workbench all along this project. 02/04/2015 19th Catia/SmarTeam Users’ Forum