Presentation is loading. Please wait.

Presentation is loading. Please wait.

BARREL 3 FIBRE ROUTE ORDER and HARNESS INSTALLATION ORDER]

Similar presentations


Presentation on theme: "BARREL 3 FIBRE ROUTE ORDER and HARNESS INSTALLATION ORDER]"— Presentation transcript:

1 BARREL 3 FIBRE ROUTE ORDER and HARNESS INSTALLATION ORDER]
RH – 5 BARREL 3 FIBRE ROUTE ORDER and HARNESS INSTALLATION ORDER] NEW +Z +Y -Z +Y RH - 6 RH - 7 2 2 +X 1 1 e e RH - 8 Phi 8 e 10 9 Phi 7 e RH - 8 11 8 Phi 6 12 7 2 Phi 5 2 13 6 14 Phi 4 1 RH - 7 5 FSI 1 Readout fibre direction on barrel circumference 15 FSI e 4 Phi 3 RH - 6 +Z end e 16 3 Phi 2 RH - 5 e e Phi 16 17 2 Phi 1 +X e Harness installation order 18 1 Phi 32 e 19 32 e Phi 31 20 31 e FSI FSI 1 21 30 1 Fibre bunch installation order e = either 2 22 29 2 23 28 24 e 25 26 27 e Harnesses are grouped in pairs for clamping eg 2nd and 3rd 4th and 5th e e 1 1 2 2

2 BARREL 3 FIBRE ROUTE HARNESS INSTALLATION ORDER NEW 01. 2004 -Z +Y +Z
LH-1 BARREL 3 FIBRE ROUTE HARNESS INSTALLATION ORDER NEW -Z +Y +Z +Y LH-2 LH-3 2 2 1 +X -X 1 e e LH-4 e Phi 8 Phi 7 e 9 10 11 LH-4 Phi 6 8 12 7 2 2 Readout fibre direction on barrel circumference Phi 5 6 13 Phi 4 14 LH-3 1 5 1 FSI FSI Phi 3 15 e 4 LH-2 -Z end e Phi 2 3 16 e LH-1 2 17 e +X Phi 1 Phi 16 -X Harness installation order e Phi 32 1 18 e 32 Phi 31 19 e 31 e 20 FSI FSI Fibre bunch Installation order e = either 1 30 1 21 29 2 22 2 28 23 e 27 24 e Harnesses are grouped in pairs for clamping eg 2nd and 3rd 4th and 5th 26 25 e e 1 1 2 2

3 +Y BARREL 3 DCS wire ROUTE +Z +Y -Z +X +Z end +X USA15 US15 FSI DCS
= cooling exhaust manifold pipes +X = pipe pair serving harnesses P09 P08 P10 P07 P11 P10 P06 P11 P05 P12 Harness locations DCS wire direction on barrel Circumference DCS wires are installed OVER fibres under clips P04 P13 P14 P03 +Z end P15 P02 P16 P01 USA15 +X US15 P17 Phi 32 P18 P31 P19 P30 P20 P29 P21 P28 P22 P27 FSI P23 P26 P24 P25 FSI DCS Cooling DCS USA15 US15 NEW

4 +Y BARREL 3 DCS wire ROUTE -Z +Y +Z -X +X -Z end +X -X Cooling DCS
US15 USA15 = cooling exhaust manifold pipes -X +X = pipe pair serving harnesses P08 P09 P08 P09 P07 P10 P06 P11 P05 P12 harness locations P04 P13 Cooling DCS P03 P14 P02 -Z end P15 P01 P16 +X -X US15 USA15 Phi 32 P17 P31 P18 P30 P19 FSI DCS wire direction on barrel circumference. DCS wires are installed OVER fibres under clips FSI P29 P20 P28 P21 P27 P22 P26 P25 P24 P23 FSI DCS NEW US15 USA15


Download ppt "BARREL 3 FIBRE ROUTE ORDER and HARNESS INSTALLATION ORDER]"

Similar presentations


Ads by Google