1 For Reverse Jet Bag Filter http://www.maniks.com/pilot-operated-pulse-valve.html

2  Maniks Pulse Jet Valve

3  Introduction:  Pulse Jet Valve Function  Working of Pulse Jet Valve  Types of Pulse Jet Valve  Maniks Pulse Jet Valves Features  Why Only Maniks Pulse Jet Valve http://www.maniks.com/pilot-operated-pulse-valve.html

4  Maniks Introduction: Maniks is a leading manufacturer and Supplier of pulse jet valve from last 30 years; we are supplying the Dust Collector Valves to wide range of industries like steel, chemicals, pharmaceuticals, bakery, oil and gas, railways, power etc. Mostly in any industry pulse jet valves are used in dust collector system to clean, gas or air flows, emission fumes. Pulse Jet Valves plays a vital role in any dust collection process, so performance and quality of valves are the major driving factor for all such industries. Our valves are known to give a very good performance in all sorts of industries and under all circumstances.Dust Collector Valves http://www.maniks.com/pilot-operated-pulse-valve.html

5  Pulse Jet Valve Function: Maniks has developed Pulse Jet Valve for reverse pulse jet bag filters which are diaphragm operated. These Dust Collector Valves has only one moving part called as Spare diaphragm. Maniks Pulse Jet Valve has exclusive spring less construction. Because of such design it gives fast opening and closing and that enhance the life of the valve. Due to high speed operation it not only saves the compressed air but also helps to provide shock air wave for removal of dust from filter bags. High flow, long life and quick diaphragm activity result into reliable and economical operation of Pulse Valve.Spare diaphragmPulse Valve http://www.maniks.com/pilot-operated-pulse-valve.html

6  Working of Pulse Jet Valve:  Maniks Pulse Jet Valves are driven by integral solenoid pilot operator. At the point when the valve is charged, the trapped air above pulse valve diaphragm is quickly exhausted causing quick opening of main diaphragm pulse valve. When the pilot valve is discharged, air escapes through drain gap of primary pulse jet valve to adjust the diaphragm pressure and immediately closes the valve. valve http://www.maniks.com/pilot-operated-pulse-valve.html

7  Duty Cycle: The relative duty time cycle for ac voltage is 20% and for DC voltage is 10 %.This implies energised time is maximum 1/5th of de-energised time for AC and 1/10th for DC voltage. http://www.maniks.com/pilot-operated-pulse-valve.html

8  Installation: Mounting in any location will not affect Pulse Jet Valve operation. However good designing practice is to avoid scale and consolidated water entering valve body for disturbance free performance. Standard end connections of BSP are provided. http://www.maniks.com/pilot-operated-pulse-valve.html

9  Pulse Jet Valve Specifications:  Electrical Standard Voltage  AC 50Hz… 24/220 Volts  DC… 24/Volts  fluctuation – + – 10%  20 W DC Current  19 VA AC Current  Maximum Medium Temperature 650C  Maximum Ambient Temperature 550C http://www.maniks.com/pilot-operated-pulse-valve.html

10  Maniks Pulse Jet Valves Features:  Low Air Consumption  Provides a more active (high force) and efficient (low air consumption) cleaning of the filter by ◦ Shorter response time ◦ Larger flow ◦ Higher peak pressure ◦ Special geometry of diaphragm and seat http://www.maniks.com/pilot-operated-pulse-valve.html

11  Why Only Maniks Pulse Jet Valve  For decades, we’ve been leading manufacturers of pulse jet valves to various hardware producers (OEMs) and to customers of dust collector valve in a large variety of industries, including: Cement Processing, Metal Plant, and Rubber Mixing/Processing. Agriculture industries, Pharmaceutical industry, Food and Beverages, Miningleading manufacturers of pulse jet valves  MANIKS caters to its customer’s requirements, provides quality service and technical support through a dedicated and highly experienced team of agents and a global network of local offices. http://www.maniks.com/pilot-operated-pulse-valve.html

12  Installation of pulse jet valve  Mounting in any position will not affect operation.  However good engineering practice is to avoid scale and condensed water entering valve body for trouble free performance.  Standard end connections of BSP are provided. http://www.maniks.com/pilot-operated-pulse-valve.html

13  Special services by Maniks  We offer special service for your existing system components for pneumatic pulse application.  To recondition your inoperative pulse jet valves and assure operating reliability as good as new.  DO NOT scrap your valves (ONLY IMPORTED) unless inspected by our experts.  We offer Spare diaphragm, Pilot solenoid and Coils for your Existing Imported Valves.Spare diaphragm  We provide special enclosures for timers such as flame proof enclosures, SS enclosures, FRP enclosures, IP65 enclosures on request. http://www.maniks.com/pilot-operated-pulse-valve.html

14  Maniks offers pulse jet valves  For reverse jet bag filter, pulse jet valve can be coated in a variety of finishes.  Integral pulse jet valves are mounted directly on the diaphragm  Pulse jet valve available for high volume/low pressure applications.  Available types of pulse jet valve in: MEP – 16, MEP – 18, MEP – 112, MEP – 114, MEP – 116, MEP – 120,Etc. http://www.maniks.com/pilot-operated-pulse-valve.html