1 Setup for routine testing of SuperNEMO scintillators in Prague
NEMO3 and SuperNEMO Collaboration Meeting in Prague Aivaras Žukauskas, Charles University in Prague , Prague

2 NEMO3/SuperNEMO collaboration meeting, Prague
Overview Motivation Black box XY table, main parameters Functionality test Scintillator's response vs irradiation position Summary and plans NEMO3/SuperNEMO collaboration meeting, Prague / 10

3 NEMO3/SuperNEMO collaboration meeting, Prague
Motivation Routine tests of big amount of scintillators should be shared among several laboratories Prague will participate in the tests Details of a testing procedure are not decided yet Some setups already exist (Bordeaux, Dubna, ...) Proposal of F.Piquemal for „multibox setup“ Plan – setup in IEAP CTU Prague Prototype setup in IPNP CU Prague NEMO3/SuperNEMO collaboration meeting, Prague / 10

4 NEMO3/SuperNEMO collaboration meeting, Prague
Black box Steel black box, 100 x 130 x 130 cm XY table easily fits inside enough space for testing bigger scintillators Aluminum bottom window 40x40 cm for electrons outcomming from spectrometer Supporting structure prepared to carry the XY table with spectrometer movable on wheels NEMO3/SuperNEMO collaboration meeting, Prague / 10

5 XY table, main parameters
Range (max.): 40x40 cm Step = 25 m Velocity: 38 cm/min Load: designed for 100 kg, tested: 35 kg Operating: serial port PC NEMO3/SuperNEMO collaboration meeting, Prague / 10

6 NEMO3/SuperNEMO collaboration meeting, Prague
Functionality test PMT Spectrometer amplifier PC X Y NEMO3/SuperNEMO collaboration meeting, Prague / 10

7 Functionality test: arrangement
PMT 3" Photonis XP5312 Scintillator 50x50x20 mm, teflon wrapping, Al mylar entrance Fixed Movable Al filter, 3 mm Pb collimator, 10mm, 45x80x80 mm XY movable 207Bi source, 160 kBq NEMO3/SuperNEMO collaboration meeting, Prague / 10

8 Pb collimator with Al filter
NEMO3/SuperNEMO collaboration meeting, Prague / 10

9 Scintillator response vs irradiation position
position scan Peak position, ADC Irradiated area  11.6 mm 1 MeV, % 91.5 88.6 85.5 20 mm 20 mm 11.8 13.8 14.1 87.3 88.7 91.9 12.7 11.5 13.9 90.6 92.5 89.9 13.7 11.9 12.5 NEMO3/SuperNEMO collaboration meeting, Prague

10 NEMO3/SuperNEMO collaboration meeting, Prague
Summary and plans The prototype for routine scintillator tests is built and tested. XY table is functioning well with the load of 35 kg. We are prepared to read and analyze data (work is in progress). Prototype will be equipped with 90Sr/90Y source (spectrometer); New testing setup will be built at IEAP CTU based on our experience with the prototype, Bordeaux, Dubna, … NEMO3/SuperNEMO collaboration meeting, Prague / 10

11 NEMO3/SuperNEMO collaboration meeting, Prague
Backup slides NEMO3/SuperNEMO collaboration meeting, Prague

12 NEMO3/SuperNEMO collaboration meeting, Prague
PMT, electronics Photonis PMT XP5312B (3")‏ XP3540B (5")‏ Voltage splitter VD202K/01 ORTEC ScintiPack ADC – PC card NEMO3/SuperNEMO collaboration meeting, Prague

13 NEMO3/SuperNEMO collaboration meeting, Prague
Scintillators Polystyrene, Dubna 50x50x20 mm hexagon with diameter 100 mm, 20 mm thick 100 mm NEMO3/SuperNEMO collaboration meeting, Prague

14 NEMO3/SuperNEMO collaboration meeting, Prague
XY table, components GLEICH – Al desks 70x70x2 cm 70x30x2 cm 30x30x2 cm MICROCON 2x step motor 2x controller 1x power supply operating software HIWIN 4x rails, 700 mm 8x carts 2x screwed rods, 590 mm bearings etc. NEMO3/SuperNEMO collaboration meeting, Prague

15 NEMO3/SuperNEMO collaboration meeting, Prague
Black box Steel construction, 100 x 130 x 130 cm XY table easily fits inside a lot of space for testing bigger scintillators Supporting structure is able to carry the spectrometer and XY table is on wheels – enables to move the black box easily Thin aluminum bottom (xx mm)‏ NEMO3/SuperNEMO collaboration meeting, Prague

16 NEMO3/SuperNEMO collaboration meeting, Prague
Double Gaussian fit NEMO3/SuperNEMO collaboration meeting, Prague