1 Validated magnetic data at cold
(SSS and S4). Status of the cold measurements in SM18 (MQ,MQM,MQY). Validated data that can be provided after cleaning Contribution from Block 4 data

2 Cold measurements in SM18 (validated data for FIDEL).
MQ’s: 41 SSS/392 at the end of the project (including 5XX series). 39 measured, 2 to be measured. MQY : 13 SSS/18 measured in SM18 (3 with TF only). MQM : 13 SSS / 60 measured in SM18 (5 with TF only) 9 of them can be used immediately for the model, for the others only partial information (to be checked). Correctors : Strength measured at the end of the cold tests : 4 MQT, 2 MQS, 3 MQTL, 8 MSCB, 6 MCBC, 1 MCBY, 4 MCS, 4 MCD.

3 Knowledge after cleaning.
Arc and special SSS’s Transfer function: TF for currents between injection and nominal in ramp up and ramp down (systematic correction with SSW measurements) Integrated harmonics: Integrated strength and multipoles between injection and nominal in ramp up and ramp down. Integrated components: Geometric, saturation, magnetization, hysteresis, decay (when it is measured). Variation of the decay with time (when it is measured). But data for a reference machine cycle!

4 Modeling of the other effects.
Powering history dependence of the decay (b2, b6) Influence of FT_current: measured on 1 MQ, 1 MQM, 1 MQY. Decay dependence of the injection current. Value of injection current : measured on 1 MQY Injection current duration : measured on 1 MQM, 2 MQY,2 MQ. A complete set of measurements foreseen for 2007.

5 Block 4 contribution Situation presented at the FQWG meeting on 31 March 2006, see: and on 19 September 2006, see: In brief: reproducibility of rotation axis from test to test gives a random error of the order of units for B2, but systematic over one run  Relative measurements are reliable: so Block 4 measurements can provide results in the form TF(I, t)+const, {bi(I,t), ai(I,t)} W-C correlations are more or less good depending on the shaft, for h102 and h103 very bad, for h100 and h101 better but still with outliers (possibly due to anomalous permeability)

6 Block 4 measurements, available after cleaning
Standard measurements now completed, that is: Load lines, mostly with min pre cycle current 100 A LHC cycles at 176 A (MQY) and 265 (MQM) injection current 48 MQM, 16 MQMC, 29 MQY apertures Need reconstruction of reference frame angle (already done for 38 MQM and 22 MQY apertures)

7 Strategy to reach reference tables for insertion quadrupoles
B4 cold data Vertical shaft Warm data QUIMM mole SM18 cold data SSW Horizontal shaft, scanner TF(I, t, History) + const. HARM(I, t, History) warm, low I TF, HARM TF(Inom) ± 5 units TF(I, t, History) + const. HARM(I, t, History) warm/cold correlation cross calibration with SSW EXPECTED UNCERTAINTIES 15 MQY , 18 MQM ε=5 units 5 MQY, 63 MQM ε=? units 4 MQY, 17 MQM ap ε=16 units 17 MQM ap ε=21 units (MQM = MQM, MQML, MQMC) Our goal: Cold TF(I, t, History) ± ε Cold HARM(I, t, History) For each MQY and MQM aperture