1 Optical Blocking Filter and Dust-proof Film for HXMT
Tianxiang Chen IHEP, Beijing, 21 March 2017

2 The overview of Optical Blocking Filter and dust-proof Film

3 The Dimension design of Optical Blocking Filters
The dimension of optical blocking filter is in accordance with collimators

4 The structure of optical blocking filter
100 nm Al ≥65 μm Ni 400 nm PI 100 nm Al PI Ni The dust-proof Film is composed by 300 nm polyimide film and ≥65 μm Ni frame with no mesh and no aluminum films compared with optical blocking filters

5 The transmittance of optical blocking filters in UV-VIS band
Different thickness Al film coated on 400 nm polyimide The transmittance is beyond the resolution of the UV-VIS spectrometer for 120 nm and 180 nm Al.

6 The transmittance of filters in soft X-ray band
The transmittance of an optical blocking filter (Al/PI/Al = 100/230/100nm) in soft X-ray band the soft X-ray transmittance of optical blocking filter (Al/PI/Al=100/246/100nm) before and after irradiation. Irradiated A and Irradiated B curves were the two samples exposed with proton irradiation in the same dose (1010 protons/cm2) and energy (10MeV)

7 Acoustic test of optical blocking filters and dust-proof film
Test condition The optical blocking filters and dust-proof films are mounted on the top and bottom of the collimators which are assembled in a light shielding structure Frequency (Hz) SPL(dB) Reference sound pressure amplitude:2×10-5 Pa Acceptance level Appraisal level Tolerance (dB) 31.5 120 124 -2 ~ +4 63 126 130 125 131 135 250 137 141 500 139 1000 133 2000 4000 122 127 -5 ~ +5 8000 115 119 Total SPL 145 -1 ~ +2 time 1 min 2 min Sound field Reverberation field

8 Acoustic test of optical blocking filters and dust-proof film
The light shielding structure are mounted in the reverberation room Samples with defect in polyimide will be broken. Samples with no mesh can also survive after acoustic test. Al/PI/Al=100/400/100 nm sample 4 and 2 Al/PI/Al=100/200/100 nm sample 3

9 Other test of optical blocking filters
Thermal cycling test conditions: Appraisal level temperature range: -50~+40℃; Thermal cycling 25.5 times; average temperature change rate 3~5℃/min; filled with dry nitrogen; Avoid direct blow the temperature monitoring point with the circulation wind in the test. Thermal vacuum test conditions: 1. Tolerance:High temperature(0~+2℃),low temperature(-2~0℃) 2. Appraisal level temperature range :-95~-15℃ 3. vacuum level:≤1.3x10-3Pa 4. Thermal circulation 6.5 times,total 13 working conditions.

10 Other test of optical blocking filters
Random vibration test condition Frequency(Hz) Power spectral density(g2/Hz) Appraisal level Acceptance level 10~100 +3dB/oct 100~600 0.125 0.05 600~2000 -9dB/oct RMS acceleration 10.14g 6.41g time 2min 1min direction Along X、Y、Z three axis Sine vibration test condition axis Frequency(Hz) acceleration / Amplitude 0~P Appraisal level Acceptance level X、Y、Z 5-15 13.5mm 9.0mm 15-85 12g 8g 85-100 10g 6.7g Scan speed Every axis:2 Oct/min Every axis:4 Oct/min Impact test condition Frequency(Hz) Appraisal level(g)Q=10 100~500 +6dB/oct 500~4000 200 direction 3 axises Times every axis 3

11 Thermal filter for LAD in eXTP
Thermal filter photo taken in IAPS LUXEL Polyimide: 1 micron Aluminum: 40 nm From the paper“Baseline design of the filters for the LAD detector on board LOFT”. Marco Barbera etc.

12 The feasibility of manufacturing thermal filters for LAD
1 micron polyimide film is easy to manufacture by spinning; 40 nm aluminum film is easy to prepare by vacuum coating; Nickel frame is easy to prepare by electroplating. 120mm 80mm 4mm 6 inch

13 Smaller thermal filter prepared for LAD
900nm PI 40nm Al Electroplating Ni frame with no mesh More than 100 micron The wafer supported by our Mask Aligner is 6 inch. The wafer supported by our magnetron sputtering deposition system is 4 inch.

14 The instruments used for measuring the properties of optical blocking filters
UV-3600Plus UV-VIS-NIR Spectrophotometer is used for measuring the transmittance of the filters in the UV-VIS-NIR band KLA-Tencor Alpha-Step D-100 profilometer is used for measuring the thickness of films