1 Process Simulation for the LCLS-II Cryogenic Systems
V Ravindranath1, H. Bai1, V. Heloin1, E. Fauve1, D. Pflueckhahn1, T. Peterson1, D. Arenius2, M. Bevins2, C. Scanlon2, R. Than3, G. Hays1, M. Ross SLAC(1), Jefferson Lab(2) & Brookhaven National Lab(3) Abstract—The Linac Coherent Light Source II (LCLS-II), a 4 GeV continuous-wave (CW) superconducting electron linear accelerator, is to be constructed in the existing two mile Linac facility at the SLAC National Accelerator Laboratory. The first light from the new facility is scheduled to be in The LCLS-II Linac consists of thirty-five, 1.3 GHz and two, 3.9 GHz superconducting cryomodules. The Linac cryomodules require cryogenic cooling for the super-conducting niobium cavities at 2.0 K, low temperature thermal intercept at K, and a thermal shield at K. The equivalent 4.5 K refrigeration capacity needed for the Linac operations range from a minimum of 11 kW to a maximum of 24 kW. Two cryogenic plants with 18 kW of equivalent 4.5 K refrigeration capacity will be used for supporting the Linac cryogenic cooling requirements. These cryogenic plants are based on the Jefferson Lab’s CHL-II cryogenic plant which uses the “Floating Pressure” design to support a wide variation in the cooling load. In this paper we describe the cryogenic process for the integrated LCLS-II cryogenic system with the help of a simulation for a 4.5 K cryoplant in combination with a 2 K cold compressor box, and the Linac cryomodules. 1. Introduction 2. LCLS-II Cryo-system Process Flow Diagram 3. Cryo-System Process Model LCLS-II 4K Cold Box (based on CHL-II cryoplant process cycle) designed for supporting a wide variation in load. For a single 4.5 K Cold Box Mode 1 (Maximum Capacity) : Cooling capacity equivalent to 18 kW of Refrigeration at 4K Mode 7 (50% of Maximum Capacity): 8.3 kW equivalent 4K Refrigeration Maximum 4.5K Liquefaction Capacity: 140 g/s (for cryomodule cool down) A. Process Modeling Approach The entire process model is split in small control volumes. At the boundary of the control volumes boundary conditions-temperature and pressure are prescribed as “independent variables” Mass Flows within each control volume starting from the “Cold End” (LINAC→Warm Compressor System) are computed using “Steady State Steady Flow Process” assumptions. B. For off-design conditions/turn down mode: The compressor (HP) discharge pressure/turbine inlet pressure is varied while ensuring that the computed turbine mass flow for each control volume satisfies the design turbine flow coefficients. The suction pressure of the HP and MP stages are solved given the mass flow from the cold box solution. Heat exchanger UA are estimated based on the reference design UA and the reduction in the mass flow rate. The temperature boundary conditions are adjusted to match with the estimated UA. Heat exchangers cooling curves are checked to ensure 2nd Law is not violated [i.e., no temperature reversal & crossing curves, inside the heat exchanger]. LN2 Dewar Cooling Tower GHe Storage Tanks Compressor Room 2 Cold Box Room Compressor Room 1 Two CDS Transfer lines Electrical Yard Klystron Gallery Figure 6: Mode 1, Maximum Capacity Process TS Diagram Figure 1: Cryoplant Building First Light One Cryoplant Two Cryomodule Strings U-Tube Connections 14 MV/m Gradient* 2.0≤ Qo ≤3.0 Gradient may be as high as 16 MV/m depending on final Qo Normal Beam Operations Two Cryoplants Two Cryomodule Strings U-Tube Connections Removed Gradient - 16 MV/m 2.0 ≤ Qo ≤ 3.0 Figure 7: Mode 7, 50% Turn Down Process TS Diagram Figure 5: LCLS-II Integrated Cryo-System Process Flow Model Table 4: Summary of 2K Operating Conditions at Cold Compressor Suction Table 1: 4.5 K Cold Box Operating Modes MODE 1 MODE 2 MODE 3 MODE 4 MODE 5 MODE 6 MODE 7 MODE 8 Max Cap Nom. Cap Max. Liq. Max. Ref Max. Fill 4K Standby 50% of Mode 1 50% of Mode 6 Heat Load Warm Shield [kW] 15.2 10.1 7.5 5 Cold Intercept [kW] 1.3 0.9 0.7 0.45 Refrigeration [kW] NA 9 0.5 0.25 Liquefaction [g/s] 15 140 45 Sub-Atm [kW] 4.0 3.14 2 Exergy [kW] 1199 844 1075 837 1215 169 553 84 4.5K Eq. Ref. Power [kW] 18 12.7 16.2 18.3 2.55 8.34 1.27 Figure 2: The simplified flow diagram shows the cryoplant configuration for the two commissioning phases of the LCLS-II Linac cryomodules, (a) First Light Configuration with a single cryoplant providing cooling capacity of both Linac strings: upstream & downstream and (b) Normal Beam Operation in which each Linac string supported by a dedicated cryoplant. (a) (b) Table 2: 2K Cold Compressor Specification-High Flow (CC1-CC5) Modes Mass Flow CC1 Suc. Press. CC1 Suc. Temp. CC Dis. Press CC Dis. Temp [g/s] [mbar] [K] [bar] [k] Max 215 27 3.5 1.2 < 30 Nom 157 28 3.6 Min 150 Table 2: 2K Cold Compressor Specification-Low Flow (CC2-CC6) Modes Mass Flow CC1 Suc. Press. CC1 Suc. Temp. CC Dis. Press CC Dis. Temp [g/s] [mbar] [K] [bar] [k] Max 132 27 3.5 1.2 < 30 Nom 120 Min 100 28 3.6 Figure 8: 2K Process Model Example (E=16 Mv/m, Q0 = 2.7x1010, Upstream LINAC) Summary: An integrated process model was developed for the LCLS-II cryogenic system using Microsoft Excel VBA tool. The process modeling capability served as a critical tool in defining the performance boundary for various components of the cryogenic system such as the 4.5K Cold Box and the 2K Cold Box. The process model developed for the LCLS-II cryogenic system was helpful in estimating the system performance under a wide variation in the Linac Heat Load (50% turn down). The process model results were also valuable in evaluating and cross checking vendor provided calculations. Figure 3: LCLS-II Linac Heat Load comprises of (1) Warm 40K, (2) 5K and (3) Cavities& 2K. The 2K heat load accounts for 80% of the total load on the cryoplant Figure 4: Shows the variation in the Linac heat load in terms of the 4.5K Equivalent Refrigeration Power versus Cavity Qo for (a) First Light and (b) Normal Beam Operation. The Equivalent 4.5 K refrigeration capacity needed for the Linac operations range from a minimum of 11 kW to a maximum of 24 kW


Download ppt "Process Simulation for the LCLS-II Cryogenic Systems"

Similar presentations


Ads by Google