Performance of Legiolert™ for Quantification of Legionella pneumophila in Potable and Nonpotable water samples Dan Broder, Theresa Knight, Amy Pednault, Veronica Newport, Brian Swalla IDEXX Laboratories, Water R&D. Westbrook, ME 04093 Copyright Colin Purrington ( Introduction The opportunistic pathogen Legionella pneumophila is a Gram-negative organism commonly found in both potable and nonpotable water systems, and is the primary cause of a severe pneumonia-type illness termed Legionnaires’ Disease. Legionnaires’ Disease is highly preventable through the use of a well designed water management plan, a key feature of which is routine monitoring of premise water systems to confirm management practices are working as intended, to keep the L. pneumophila colonization levels below a minimum accepted level. Here we present a comparison of a new culture based tested called Legiolert to multiple standard culture methods for the quantification of L. pneumophila. Legiolert cultures exclusively L. pneumophila in an accurate quantification device and utilizes simple, fixed protocols and an easy, objective reading step. Method validations and field trials were conducted according to ISO-13843, ISO and Alternate Test Protocol statistical approaches, the results of which are presented. Results Results North American nonpotable water trial Sensitivity comparison (Table 4 and Figure 4): 0.1mL direct plating +/- acid (GVPC, PCV, CCVC, or DGVP) vs. 0.1mL Legiolert Legiolert showed equivalent sensitivity vs. all methods except DGVP Legiolert specificity: Subculturing of 671 wells in the full study revealed 652/671 (96.5%) were confirmed as L. pneumophila. German potable water trial Sensitivity comparison (Table 1 and Figure 2): 100mL MF + acid (GVPC) vs. 100mL Legiolert Legiolert showed greater sensitivity 1mL direct plating (GVPC) vs. 1mL Legiolert Equivalent sensitivity for both methods Legiolert specificity: Participants subcultured from positive QuantiTrays in order to confirm the specificity of Legiolert. Of the 716 trays with positive signals, 10% of all wells were examined on BCYE and BAP, of which 1991/2034 (97.9%) were confirmed as L. pneumophila. North American potable water trial Sensitivity comparison (Table 2 and Figure 3) mL concentrated and plated +/- acid treatment (CCVC) vs. 10mL Legiolert True positivity evaluation revealed that 199/199 Legiolert specificity: Subculturing of 199 positive wells revealed 199/199 (100%) were confirmed as L. pneumophila. Figure 2. Comparison of Legiolert to ISO for German potable water. Table 1. ISO relative difference analysis for Legiolert vs. German potable water. Volume compared Mean Rel. Diff. Lower 95% CI Upper N 100mL 89.3% 72.6% 106.1% 445 1mL -3.0% -15.7% 9.7% 278 Figure 4. Comparison of Legiolert to 4 laboratory standard culture methods for North American nonpotable water. Materials and methods Legiolert was evaluated against multiple culture methods: ISO Standard methods SM9260J CDC Procedures for Recovery of Legionella from the Environment Custom lab method 1 – PCV selective medium Custom lab method 2 – DGVP selective medium Statistics used: For ISO – Mean relative difference For all others – Wilcoxon signed rank Table 3. Wilcoxon signed rank analysis for Legiolert vs. SM9260J for N. American potable water. Parameter vs. CDC method custom PCV method SM9260J custom DGVP method N 92 74 49 76 Prob > |S| 0.258 0.328 0.728 <.0001 Prob > S 0.129 0.164 0.636 1.0000 Prob < S 0.871 0.836 0.363 p < 0.05 indicates a significant difference % False positive = 3.6% (652/671 confirmed as L. pneumophila) Table 2. Wilcoxon signed rank analysis for Legiolert vs. SM9260J for N. American potable water Parameter Value vs. SM9260J N 74 Prob > |S| <.0001 Prob > S Prob < S 1 p < 0.05 indicates a significant difference % False positive = 0% (199/199 confirmed as L. pneumophila) Conclusions: Difficulties associated with running gold standard culture methods can be several fold: Method variability from lab to lab High level of expertise required, still resulting in subjectivity Laborious procedure is error prone Multiple parallel conditions frequently required. Legiolert solves these problems by providing simple and easy to use protocols which are fixed for each water type. These characteristics, in conjunction with equivalent performance to standard culture methods, make Legiolert an excellent tool for consistent routine monitoring in conjunction with a water management plan. Further information: Figure 3. Comparison of Legiolert to SM9260J for N. American potable water. References: Standard Methods Committee (2007) Standard Methods for the Examination of Water and Wastewater. Chapter 9260J: Detection of Pathogenic Bacteria. Legionella. U.S. Department of Health and Human Services Centers for Disease Control and Prevention (2007). Procedures for the Recovery of Legionella from the Environment. ISO (2004) Water Quality – Detection and Enumeration of Legionella – Part 2: Direct membrane filtration method for waters with low bacterial counts. Geneva: International Organization for Standardization. ISO (2014) Water Quality – Requirements for the comparison of the Relative Recovery of Microorganisms by Two Quantitative Methods. Geneva: International Organization for Standardization. Oshiro, RK, on behalf of U.S. Environmental Protection Agency, Office of Water (2010). EPA Microbiological Alternate Test Procedure (ATP) Protocol for Drinking Water, Ambient Water, Wastewater Monitoring Methods. September 2010. Figure 1. Legiolert protocols for potable and nonpotable water. Example standard method protocols for ISO and CDC.


Download ppt "IDEXX Laboratories, Water R&D. Westbrook, ME 04093"

Similar presentations


Ads by Google