1 Intelligent trigger for Hyper-K
Akitaka Ariga University of Bern, Switzerland

2 Recent changes in design
Conventional design 10 compartments Noise rate in each of them is about SK scale Recently coming back to SK style For cost optimization 1 (or a few) large detector Longer gate width Larger number of PMT per detector Large noise rate to cope

3 Noise rate in Hyper-K SK -> HK : Smaller signal and larger background Detector size -> larger -> gate width longer 200ns ->500ns # of sensors -> larger N 12k -> 20k ~ 80k Noise rate -> larger N 4kHz -> 10kHz Photo coverage -> smaller  smaller S 40% -> 15% ~ 20% SK: 200ns x 12,000PMTs x 4kHz = 10 hits/gate (SK threshold = 33 hits) HK:500ns x 20,000PMTs x 10kHz = 100 hits/gate Direct impact on low energy neutrino physics, supernova and partially on proton decay

4 Signal / background Signal: 6 hits/MeV (SK,40%), 3 hits/MeV (HK,20%)
Noise level: expected number of hits in a gate SK: 200ns x 12,000PMTs x 4kHz = 10 hits/gate HK:500ns x 20,000PMTs x 10kHz = 100 hits/gate Noise hits will be dominant at low energy (E<30MeV) Solar neutrino Signal in SK (40%) Supernova Signal in HK (20%) Noise level in HK Noise level in SK

5 Detectable energy Detectable : Signal+Noise > Noise + noise fluctuation Noise issue is essential to access low energy physics below 20 MeV, where most of supernova, solar neutrino, some of proton decay signals exist. Signal + noise in SK Solar neutrino Supernova detectable Signal + noise in HK Noise + 5s fluctuation = realistic threshold

6 Need to improve trigger quality
Be intelligent! Use of 4D information hits, (x,y,z,t) Many ideas Exploit TOF information to narrow gate width  next page Vertex calculation: 2 hits can make a hyperbolic surface, 3 or more hits could make unique identification of vertex position  high-order hough transform like method – may not work with high BG Ring pattern fitting C Hyperbolic by B, C A B Hyperbolic by A, B

7 One of many ideas: Sub-volume triggering
The largest factor of noise increase is gate width due to large detector  Let’s make it small. Sub-volume triggering Divide detector into several sub-volumes In each sub-volume, perform inversion of hit-time using distance from hit-positions  smaller gate width, canceling detector size increase Large computing power required triggering in O(100) sub-volumes projected params A’ center of sub-volume V A t t’

8 Intelligent trigger with GPUs
To profit of 4D data, need more computing power GPU is an ideal solution: Expertise in LHEP-Bern GPU: Graphic Processing Unit Parallel processing with O(1000) processing cores Triggering code can be highly parallelized

9 Parallel processing GPU allow you a parallel processing with thousands of processing cores. Serial process CPU Parallel process GPU task 1 task 2 .

10 High computing power = 8 TFLOPS = 5-10 TFLOPS NVIDIA Geforce Titan Z
1 full tower of CPU based computing cluster = 5-10 TFLOPS FLOPS = floating-point operations per second

11 Experience of LHEP-Bern 1: High speed emulsion reconstruction
Custom-made real-time scanning microscope CMOS camera 0.5 – 2.4 Gbyte/s (Real time) 3D track reconstruction with GPUs x90 faster Geforece GTX TITAN x 3 2688 cores, 6GB memory, 4.5 TFLOPs in each JINST 9 P04002 (2014), GTC2014, GPU in high energy physics (2014)

12 Experience of LHEP-Bern 2: Reconstruction of LAr-TPC
LAr detector (ArgonTube at LHEP-Bern) Hough transform with GPU x 50 faster processing achieved x 50 faster

13 Possible hardware for HK
Data will be distributed to several nodes equipped with GPUs O(100) processes run with O(100,000) GPU cores Processing machine CPU CPU GPU Processing machine CPU 2.5 Gbyte/s CPU GPU 4U processing server 2 CPU x 10 cores 8 GPUs (24,000 cores) Processing machine CPU CPU GPU

14 Status and outlook Discussing with the relevant people
electron generated at center of detector with WCSim Discussing with the relevant people Started using WCSim package Developing algorithm, checking performance (efficiency, S/N) on CPU Algorithm to be implemented in GPUs signal background

15 Summary Noise rate is a crucial issue for low energy neutrino, supernova and proton decay We are investigating an intelligent trigger by exploiting 4D data from detector Larger computing power of O(100) could be necessary  An use of GPUs is a promising solution More result will come soon

16

17 Trigger for Hyper-K In SK, the triggering has been done by software trigger. All hits are distributed to 6 PCs (48 processes) BG level kept low, so that SK performs low energy neutrino physics In HK, several issues (detector size, dark hits, NPMT) substantially increase BG