Presentation is loading. Please wait.

Presentation is loading. Please wait.

biomechanics of the spine

Similar presentations


Presentation on theme: "biomechanics of the spine"— Presentation transcript:

1 biomechanics of the spine
Stanford Hospital and Clinics April 26, 2010 biomechanics of the spine

2 Motion segment VERTEBRAE FACET JOINT Carry 70-90% of static axial load
Vary in cervical, thoracic, lumbar, sacral and coccygeal FACET JOINT Carry 10-20% of static axial load Highly innervated and can be a source of low back pain Cervical spine: facet orientation is roof-tile shaped, coupling lateral bending and axial rotation in an opposite direction (i.e. bending the head to the left results automatically in an axial rotation to the left Thoracic spine: coronal plane orientation with a slight inward tilt in the transverse plane, permitting axial rotation movements with the center of rotation projecting into the vertebral body Lumbar spine: sagittal plane orientation of facet joints, effectively blocking axial rotation movements

3 Degree of Facet range of motion

4 Motion segment INTERVERTEBRAL DISC
Nucleus pulposus surrounded by annulus fibrosus Covers 30-50% of disc surface area and contains exclusively type II collagen fibers in a aqueous gel rich in proteoglycans Sharpey fibers insert from the annulus fibrosus into the epiphyseal ring Endplates are composed of a dense layer of trabecular bone further covered with a layer of hyaline cartilage Vascular channels within the vertebral bodies have been observed to run directly along the endplates, representing the predominant nutrient source for adult disc cells Cartilaginous end plates undergo progressive calcification with age, which impedes nutrition and contribute to the progressive disc degeneration throughout adulthood Disc degeneration also affects other elements of the motion segment. Through disc height loss and apparent changes in axial load transmission, the facet joints become incongruent and may become mechanically overloaded. Also, loss of disc height will result in ligament laxity, hypermobility and loss of segmental stiffness.

5 Intradiscal pressure for various activities

6 Motion segment MUSCLES LIGAMENTS

7 SPINAL MOTION Six degrees of freedom
Motion rarely involve a single degree of freedom only Segmental Instability “loss of ability of the spine under physiological loads to maintain its pattern of displacement so that there is no initial or additional neurological deficit, deformity or incapacitating pain.” - White & Panjabi

8 Biomechanics of spinal stabilization
Goals of spinal arthrodesis are: To support the spine when its structural integrity has been severely compromised To maintain correction following mechanical straightening of the spine. To prevent progression of deformity. To alleviate or eliminate pain by stiffening a region of the spine. Choose a stabilization method which will best achieve these goals. Therefore, the surgeon needs to have an understanding of how load is transferred throughout the spine and how this load transfer is altered by a specific injury or pathology.

9 Posterior stabilization
PROVIDES STABILIZATION IN EXTENSION AND LATERAL BENDING Pullout strength of pedicle screws is directly related to bone density It is possible to achieve an increase in pullout strength with convergent screw trajectories. Parallel pedicle screw in short segment constructs can result in an unstable “four bar” mechanism. Diagonal cross-linking is preferable to the horizontal configuration in terms of rotational stability. An increase in rod diameter provides a more stable construct, but at the same time produces higher internal loads in the implant, on the clamping device, and on the pedicle screws; thus, higher risk of screw breakage.

10 Posterior stabilization

11 Posterior stabilization

12 Posterior stabilization
In the thoracic spine, smaller overall pedicles can result in complications. An alternative is to increase pullout strength with extrapedicular screw trajectory.

13 Anterior stabilization
PROVIDES STABILIZATION IN FLEXION AND LATERAL BENDING. Anterior cervical plates function as tension band during extension and buttress plate during flexion. Constrained cervical systems have a rigid, angle-stable connection between the plate and screws, whereas, unconstrained systems rely on friction generated by compression of the plate against the anterior cortex for stability. In extended biomechanical testing, constrained systems have shown a greater rigidity over time, whereas, unconstrained systems can lose stability over time. No significant difference in stability between monocortical and bicortical screws in the cervical spine.

14 INTERVERTEBRAL CAGES Distraction of facet joints may be associated with instability

15 Adjacent segment effects
Fusing one or two levels will lead to increased stress at the remaining adjacent levels, the remaining motion segments will have to take up and accommodate the remaining motion of the spine, these adjacent levels will then tend to age and degenerate faster because of the resultant increased load and stress.

16 Arthroplasty of the spine
Many spinal arthroplasty surgeons propose that by performing a disc replacement and restoring motion to a diseased spinal segment, this reconstructed spinal motion segment will offload the stress to the adjacent levels and actually lower the risk of onset of accelerated adjacent segment degeneration. The spine is a mobile structure and motion will occur at the places of least resistance and stiffness, if motion can be restored by a disc replacement then this will lead to reduced stresses at other more degenerated parts of the spine

17 “Biomechanical study on the effect of cervical spine fusion on adjacent-level intradiscal pressure and segmental motion” Eck JC, Humphreys SC, Lim TH, Jeong ST, Kim JG, Hodges SD, An HS. Spine 2002. Intradiscal pressure and segmental motion are increased in adjacent disc segments after fusion. This cumulatively translates into increased stress on the adjacent non-operated discs, which can accelerate the rate of disc degeneration.

18 “Radiculopathy and myelopathy at segments adjacent to site of previous anterior cervical arthrodesis” Hilibrand AS, Carlson GD, Palumbo MA, Jones PK, Bohlman HH. J Bone Joint Surg, 1999. Studied 374 patients and found that symptomatic adjacent segment disease occurred at a relatively constant rate of 2.9% during the decade after surgical fusion.

19 Indications and contraindications
Failure in medical management Normal cervical alignment and mobility with radiculopathy cause by: soft or hard disc herniation foraminal osteophytes myelopathy due to soft disc herniation Arthroplasty is contraindicated in the setting of significant segmental or global deformity Radiographic instability should be treated with arthrodesis Recent history of infection or osteomyelitis preclude the use of prosthetic device Relative contraindications are RA, RF, osteoporosis, cancer, chronic corticosteroid use Marked degenerative changes and no segmental motion cannot be expected to regain mobility by implanting a total disc replacement Outcomes of patients with isolated axial cervical pain who are treated with an arthroplasty have not been well delineated

20 DISC ARTHROPLASTY Artificial discs approved by the FDA for use:
Charite by DePuy for use in the lumbar spine ProDisc by Synthes for use in the lumbar spine and cervical spine Prestige by Medtronics for use in the cervical spine Bryan Disc by Medtronics for use in the cervical spine These are FDA approved for one-level applications, after clinical trials showed patient improvement in motion and pain equivalent to spinal fusion. Two-level disc replacement surgery is considered experimental in the United States, but has been performed in Europe for many years. Some insurance companies in the United States do not cover the surgery, still classifying it as experimental. Effective August 14, 2007, the Centers for Medicare & Medicaid Services (CMS) will not cover Lumbar Artificial Disc Replacement (LADR) for patients over the age of 60, on a national basis. Individual localities regulate the use of the procedure in patients 60 and under.

21 Prestige® ST Cervical disc
Became available in 2002 Constructed of stainless steel in a two-piece ball and trough configuration and attaches to the vertebrae with screws Provides relatively unconstrained motion comparable to that of a normal cervical spinal segment Angulation between the base and anterior portion matches the normal anatomy of cervical vertebrae The surfaces of the device contacting the endplates are grit-blasted to promote bone osteointegration.

22 Prestige® LP Cervical disc
Manufactured from a unique titanium ceramic composite material that is highly durable and CT/MRI compatible Ball and trough configuration is identical to Prestige ST Initial fixation is achieved via four rails, two on each component A porous titanium plasma-spray coating on the endplate surface facilitates bone ingrowth and long-term fixation

23 Bryan cervical Disc Conceived in the early 1990s by neurosurgeon Vincent Bryan and first implanted in Belgium in 2000 by Dr. Jan Goffin. Cervical disc replacement designed to allow for motion similar to the normal cervical spine functional unit. Consists of two titanium alloy shells with a polyurethane nucleus. The bone implant interface of each shell has applied porous coating to facilitate ingrowth of bone and promote long-term stability. The nucleus is surrounded with a polyurethane sheath to establish a closed articulation environment. Sterile saline is injected into this sheath and functions as an initial lubricant. Titanium alloy seal plugs allow for retention of the saline lubricant Small anterior flanges on the shells serve to grasp the device for insertion.

24 Prodisc-C cervical disc
Similar design principles as the Prodisc lumbar prosthesis. First implantation was in December 2002. Metal-on-polyethylene articulating device consisting of two cobalt-chromium molybdenum endplates and ultra high molecular weight polyethylene inlay. The endplates are initially secured to the vertebral body with central keels and have a plasma sprayed titanium coating for long-term fixation stability.

25 Pcm (Porous Coated Motion) Prosthesis
Made by Cervitech Inc, Rockaway, NJ. Uses metal on polyethylene articulating surface The cobalt-chromium-molybdenum alloy components are covered with a TiCaP porous coating Immediate fixation is achieved by inserting the prosthesis in a “press-fit” fashion.

26 Kineflex C Prosthetic Device
Developed in Africa and manufactured by Spinal Motion, Inc, Mountain View, CA Uses a three-piece modular design consisting of two-cobalt-chromium-molybdenum endplates and a mobile core. Opposing sides of the endplates have a highly polished concave articulating surfaces. The core is indented at its equator to permit seating within a retention ring which is an integral part of the inferior endplate. This prevents subluxation of the core. Initial fixation is achieve via central keel and a pyramidal surface. Endplate are plasma-sprayed.

27 Cervicore disc Total cervical disc replacement by Stryker Spine, Allendale NJ. Constructed of cobalt-chromium alloy. Articulation occurs across a pair of saddle-shaped bearing surfaces. Two fins containing three fixation spikes provide initial stability. Bony contact surfaces have titanium plasma-sprayed coating.

28 Future direction Some companies are working to develop products and methodologies to replace only the inner portion of the disc, referred to as disc nucleus replacement. These new techniques would allow for posterior insertion and a potentially shorter surgery with fewer complications. Recently new artificial discs with innovative designs that incorporate an artificial nucleus to allow shock absorption and a woven fiber annulus for graded variable motion resistance in all directions have been approved in Europe. These next generation implants are designed to reduce the risk of implant migration found with earlier designs. They also should protect against impact injury and facet joint wear.

29 Dynamic stabilization (Dynesys)

30 Interspinous process distraction


Download ppt "biomechanics of the spine"

Similar presentations


Ads by Google