Presentation is loading. Please wait.

Presentation is loading. Please wait.

24v 12v 0v Tx+ Tx- SPK1 SPK2 MIC PA 1 PA 2 Use CW1308 Twisted Pair or Tunstall Telecom Cable (use 0.8mm pair for 24v & 0v) Minimum Cabling requirements.

Similar presentations


Presentation on theme: "24v 12v 0v Tx+ Tx- SPK1 SPK2 MIC PA 1 PA 2 Use CW1308 Twisted Pair or Tunstall Telecom Cable (use 0.8mm pair for 24v & 0v) Minimum Cabling requirements."— Presentation transcript:

1

2

3

4 24v 12v 0v Tx+ Tx- SPK1 SPK2 MIC PA 1 PA 2 Use CW1308 Twisted Pair or Tunstall Telecom Cable (use 0.8mm pair for 24v & 0v) Minimum Cabling requirements for Advent ‘xt’ with Door Entry Combined & with All Call Minimum 5 twisted pairs required

5 Door Entry X 16 Up to 16 Door Entry Panels can be fitted to the system.

6 Door Panel Cabling + - 12v Lock Release W00525 12v/2A PSU ZPD310 Door Panel 1.00mm Pair 12v 0v TX+ TX- C1 C2 CONC T/G EXLK 0v LKSP LKRT + - To Network Wiring SP1 SP2 MIC LCK PSU VR1 1 2 3 4 5 6 7 8 ON VR6 VR3 VR4 VR2 VR5 DIL SWITCH 1 ‘1’ SET ADDRESS 2 ‘2’ ADDRESS 3 ‘4’ 0 TO 15 4 ‘8’ 5 ON FOR DIGITAL 6 BOTH ON FOR 7 MANAGER BUTTON 8 OFF POT FUNCTION VR1 LCD CONTRAST VR2 AUDIO TO PHONE VOL VR3 AUDIO TO DOOR VOL VR4 VOX SENSITIVITY VR5 AUDIO TO WARDENS VR6 AUDIO FROM WARDENS Note: Diode MUST Be fitted on Locks (as without them back EMF can cause damage to the Door Panel Circuits) Note: Door Panel MUST be Earthed to mains earth

7 Door Panel Cabling ZPD310 Door Panel 12v 0v TX+ TX- C1 C2 CONC T/G EXLK 0v LKSP LKRT + - SP1 SP2 MIC LCK PSU VR1 1 2 3 4 5 6 7 8 ON VR6 VR3 VR4 VR2 VR5 DIL SWITCH 1 ‘1’ SET ADDRESS 2 ‘2’ ADDRESS 3 ‘4’ 0 TO 15 4 ‘8’ 5 ON FOR DIGITAL 6 BOTH ON FOR 7 MANAGER BUTTON 8 OFF POT FUNCTION VR1 LCD CONTRAST VR2 AUDIO TO PHONE VOL VR3 AUDIO TO DOOR VOL VR4 VOX SENSITIVITY VR5 AUDIO TO WARDENS VR6 AUDIO FROM WARDENS A00381 Termination Board

8 Advent xt Intercom to Flat Telephone Cabling for Door Entry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 20 19 18 17 16 0v Com Advent xt Intercom Termination Board 10v 0v SCLK SDATA C2 C1 STROBE ZFT320 Telephone Handset To Advent xt Network Wiring Copy for each Flat To Slave H/Set

9 Advent xt Intercom Set Up for Door Entry

10 ‘Master’ Telephone Set Up for Door Entry 10v 0v SCLK SDATA C2 C1 STROBE ZFT320 Master Telephone Handset SDATA SCLK A B LK3 LK2 LK1 Fit LK1/LK2 in the SDATA/SCLK positions A – Master B - Slave Fit LK3 to position ‘A’ for Master Telephone

11 ‘Slave’ Telephone Set Up for Door Entry 10v 0v SCLK SDATA C2 C1 STROBE ZFT320 Slave Telephone Handset SDATA SCLK A B LK2 LK1 Fit LK1/LK2 in the SDATA/SCLK positions A – Master B - Slave Fit LK3 to position ‘B’ for Slave Telephone LK3

12 Programming of Door Entry Advent xt Warden Call System Programming Diagnostics Door Entry Setup Number of Door Panels: 02 BST Adjustment: 01 Speech Time: 60 Lock Time: 10 Privacy Time: 60 Access Code 001: 1111 Access Code 002: FFFF Access Code 003: FFFF Access Code 004: FFFF Ring Cycles: 08 Door Open LED Enable: 01 Timed Coded Access Enabled: 00 Trade On Time 000: FFFFTrade On Time 001: FFFFTrade On Time 002: FFFF Trade On Time 003: FFFFTrade On Time 004: FFFFTrade On Time 005: FFFF Trade On Time 006: FFFFTrade On Time 007: FFFFTrade On Time 008: FFFF Trade On Time 009: FFFFTrade On Time 010: FFFFTrade On Time 011: FFFF Trade On Time 012: FFFFTrade On Time 013: FFFFTrade On Time 014: FFFF Trade On Time 015: FFFFTrade On Time 016: FFFFTrade On Time 017: FFFF Trade On Time 018: FFFFTrade On Time 019: FFFFTrade On Time 020: FFFF Trade Off Time 000: FFFFTrade Off Time 001: FFFFTrade Off Time 002: FFFF Trade Off Time 003: FFFFTrade Off Time 004: FFFFTrade Off Time 005: FFFF Trade Off Time 006: FFFFTrade Off Time 007: FFFFTrade Off Time 008: FFFF Trade Off Time 009: FFFFTrade Off Time 010: FFFFTrade Off Time 011: FFFF Trade Off Time 012: FFFFTrade Off Time 013: FFFFTrade Off Time 014: FFFF Trade Off Time 015: FFFFTrade Off Time 016: FFFFTrade Off Time 017: FFFF Trade Off Time 018: FFFFTrade Off Time 019: FFFFTrade Off Time 020: FFFF Call Transfer Time On: FFFFCall Transfer Time Off: FFFF

13 Programming of Door Entry Advent xt Warden Call System Programming Diagnostics General Setup System Type: 01Subunits: 32Sununit Fault Report: 00 Network Receiver Units: 00 Network Exchange Units: 00 Network Keyswitch Units: 00 PBX Ring Enable: 00 All Call Enable: 00 Fire Tone Enable: 00 BT Line Monitor Enable: 01 If the Advent xt system has 32 Intercoms fitted with 2 x Door Entry Panels, these 2 x Panels are NOT included in the Number Of Subunits programming.

14 Programming of Door Entry Advent xt Warden Call System Programming Diagnostics Tenants Unit Identity Simply program Door Panel I.D’s after the last Intercom I.D Flat 001: 0001Flat 002: 0002Flat 003: 0003Flat 004: 0004Flat 005: 0005Flat 006: 0006Flat 007: 0007Flat 008: 0008 Flat 009: 0009Flat 010: 0010Flat 011: 0011Flat 012: 0012Flat 013: 0013Flat 014: 0014Flat 015: 0015Flat 016: 0016 Flat 017: 0017Flat 018: 0018Flat 019: 0019Flat 020: 0020Flat 021: 0021Flat 022: 0022Flat 023: 0023Flat 024: 0024 Flat 025: 0025Flat 026: 0026Flat 027: 0027Flat 028: 0028Flat 029: 0029Flat 030: 0030Flat 031: 0031Flat 032: 0032 Flat 033: 0600Flat 034: 0601Flat 035: FFFFFlat 036: FFFFFlat 037: FFFFFlat 038: FFFFFlat 039: FFFFFlat 040: FFFF

15 Programming of Door Entry (for Call Transfer) Advent xt Warden Call System Programming Diagnostics Door Entry Setup Number of Door Panels: 02 BST Adjustment: 01 Speech Time: 60 Lock Time: 10 Privacy Time: 60 Access Code 001: 1111 Access Code 002: FFFF Access Code 003: FFFF Access Code 004: FFFF Ring Cycles: 08 Door Open LED Enable: 01 Timed Coded Access Enabled: 00 Trade On Time 000: FFFFTrade On Time 001: FFFFTrade On Time 002: FFFF Trade On Time 003: FFFFTrade On Time 004: FFFFTrade On Time 005: FFFF Trade On Time 006: FFFFTrade On Time 007: FFFFTrade On Time 008: FFFF Trade On Time 009: FFFFTrade On Time 010: FFFFTrade On Time 011: FFFF Trade On Time 012: FFFFTrade On Time 013: FFFFTrade On Time 014: FFFF Trade On Time 015: FFFFTrade On Time 016: FFFFTrade On Time 017: FFFF Trade On Time 018: FFFFTrade On Time 019: FFFFTrade On Time 020: FFFF Trade Off Time 000: FFFFTrade Off Time 001: FFFFTrade Off Time 002: FFFF Trade Off Time 003: FFFFTrade Off Time 004: FFFFTrade Off Time 005: FFFF Trade Off Time 006: FFFFTrade Off Time 007: FFFFTrade Off Time 008: FFFF Trade Off Time 009: FFFFTrade Off Time 010: FFFFTrade Off Time 011: FFFF Trade Off Time 012: FFFFTrade Off Time 013: FFFFTrade Off Time 014: FFFF Trade Off Time 015: FFFFTrade Off Time 016: FFFFTrade Off Time 017: FFFF Trade Off Time 018: FFFFTrade Off Time 019: FFFFTrade Off Time 020: FFFF Call Transfer Time On: 2000Call Transfer Time Off: 0700

16 Programming of Door Entry (for Call Transfer) Advent xt Warden Call System Programming Diagnostics Door Entry Setup Call Transfer Time On: 2000Call Transfer Time Off: 0700 Example: Call Transfer Time set from 20:00 to 07:00 (8pm till 7am) Any calls made from the Front Door Panel to the residents during these times will be automatically transferred to the current system mode. (i.e Onsite Scheme Manager, Local Offsite or Remote Offsite).

17 Programming of Door Entry (for Call Transfer) Advent xt Warden Call However, even when the Call transfer times have been programmed via the P.C (for example 8pm till 7am) Individual Flats can be still be EXCLUDED from the call transfer mode by ENABLING 24HR DOOR ENTRY CALLS via code 8004* for each Flat. It is then again possible to revert these individual Flats back to CALL TRANSFER TIMES mode by DISABLING 24HR DOOR ENTRY CALL via code 8005* for each Flat. It is possible to LIST FLATS WITH 24HR DOOR ENTRY CALLS by simply entering code 8006*. It is also possible to CLEAR ALL 24HR DOOR ENTRY CALLS via code 8007*, so that all Flats are reverted back to CALL TRANSFER TIMES MODE.

18 Programming of Door Entry (for Flat Transfer) Advent xt Warden Call If a resident is on Holiday for example, that resident can get their Door Entry Calls tranfered to another Flat. (i.e Door Entry calls to Flat 6 can be transferred to Flat 26 to accept the calls). This can be achieved by entering code 8000* ENABLE DOOR ENTRY FLAT TRANSFER then simply entering the Flat No. that requires transferred, (e.g 6) then entering the Flat number that will be accepting the transferred Door Entry call (e.g 26). Flat 6 Flat 26

19 Programming of Door Entry (for Flat Transfer) Advent xt Warden Call If the resident then returns from Holiday for example, that resident can get their Door Entry Calls tranfered back to their own Flat. (i.e Door Entry calls to Flat 6 accepted by Flat 6). This can be achieved by entering code 8001* DISABLE DOOR ENTRY FLAT TRANSFER then simply entering the Flat No. that requires transferred back (e.g 6) Flat 6 Or, if this is the only DOOR ENTRY FLAT TRANSFER on the system then you can simply CLEAR ALL DOOR ENTRY FLAT TRANSFERS by entering code 8003* It is also possible to LIST FLATS WITH DOOR ENTRY FLAT TRANSFER by entering code 8002*

20 Programming of Door Entry (Telephones in Privacy) Advent xt Warden Call Privacy LED Red If any of the telephones are in PRIVACY MODE then a simple code 8008* can be entered to LIST FLATS WITH TELEPHONE IN PRIVACY MODE. However, if 2 Telephone Handsets are installed in a Flat, both telphones MUST be in PRIVACY MODE for system to list it as PRIVACY ON. Also, if any telephones have faults then a simple code 8009* can be entered to LIST FLATS WITH TELEPHONE FAULTS.

21 Door Entry Operation When calling a resident from the Door Panel simply type in the residents Flat Number followed by the CALL button.

22 Door Entry Operation (when 2 or more Door Panels are fitted) Flat 26 Example: When Flat 26 Telephone is called from a Door Panel All other Door Panels will Display ‘BUSY’ and NO Door Entry calls can be made from any other panel. Door Panel 1 Door Panel 2 However, calls to the Warden/Scheme Manager CAN be made from this and other Panels. The ACCESS CODE can also be used. Warden’s Dect Telephone