POSITIVE CONTROL SAMPLES FOR PARENTERAL PRODUCT CLASSES ASTM F02 Committee on Barrier Packaging.

Similar presentations


Presentation on theme: "POSITIVE CONTROL SAMPLES FOR PARENTERAL PRODUCT CLASSES ASTM F02 Committee on Barrier Packaging."— Presentation transcript:

1 POSITIVE CONTROL SAMPLES FOR PARENTERAL PRODUCT CLASSES ASTM F02 Committee on Barrier Packaging

2 CHALLENGE Various methods for positive controls Dependent on package contents  Compressible fluid (gas)  Non-Compressible fluid (liquids)  Various liquid characteristics “Proteinaceous product may interfere with defect detection.” 1 1 Li, Lei. American Pharmaceutical Review. February 20, 2013. Container Closure Integrity Testing Method Development and Validation for Prefilled Syringes.

3 PARENTERAL TARGET LEAK SIZES Study Details:  Used pipettes.  Full submersion and pressure cycling in microbial bath.  Liquid continuously present on both sides of the defect. Kirsch, et al, PDA J Pharm Sci & Technol 51, 5, 1997 p. 200

4 POSITIVE CONTROL TYPES Mechanical (drilling, puncture, crack formation, etc.) Pipette (“Sharp Edge”) Capillary Laser Drilled Defect Controlled Air Flow Natural Vial Defect

5 DEFECT SIZE & GAS FLOW RATES  Direct relationship between defect size and gas flow rate.  Various methods available to simulate gas flow rates.

6 LASER DRILLED DEFECTS Nominal hole size 5 µm

7 CAPILLARY (TUBE) DEFECTS Accuracy of a 20 micron ID capillary; Avg. = 20.1 μm, σ = 0.54 μm.

8 CAPILLARY FLOW RATE 30µ Pinhole – ~3.26 sccm 30µ 20mm Channel – ~0.16 sccm 30µ 40mm Channel – ~0.08 sccm

9 PIPETTE GAS FLOW Pipette tip formed to create specific diameter defect. Certified with flowrate. Sharp defect geometry. Target defect diameter at tip.

10 PIPETTE GAS FLOW RATE

11 COMPARABLE GAS FLOW RATES

12 PIPETTE MENISCUS Significant liquid surface area within pipette.

13 CAPILLARY ACTION Factors of Capillary Action  liquid-air surface tension(force/unit length),  θ is the contact angle,  ρ is the density of liquid  g is local acceleration due to gravity  r is radius of tube Thus the more narrow the space in which the water can travel, the further up it goes. Variables for Water: γ = 0.0728 N/m at 20 °C, θ = 0° (cos(0) = 1), ρ is 1000 kg/m 3, and g = 9.81 m/s 2.

14 PIPETTE MENISCUS 10 micron – 0.48mm meniscus diameter 5 micron – 0.26mm meniscus diameter

15 PIPETTE SUBMERSION 5 Micron - 15 Seconds Submersion 5 Micron - 1 Minute Submersion 5 Micron - 10 Minutes Submersion 10 Micron - 15 Seconds Submersion Damaged Pipette Tip – 5 seconds

16 PREFERENTIAL CONDITIONS “Proteinaceous product may interfere with defect detection.” 1 1 Li, Lei. American Pharmaceutical Review. February 20, 2013. Container Closure Integrity Testing Method Development and Validation for Prefilled Syringes.  Naturally occurring defects and laser defects are susceptible to blockage when testing.  Solutes may be deposited internal to the defect passage during testing due to liquid vaporization.  Pipettes draw liquid through the calibrated defect into the pipette cavity ahead of test.  Volume of liquid exposed to vacuum with low potential for solute blockage before test.  Ideal condition for detection.  Not representative of naturally occurring defects.

17 PIPETTE FLOW RATE COMPARISON

18 CAPILLARY ACTION AND DEEP VACUUM 1.0 mm 3 of water exposed to the test chamber before any vacuum force, the liquid vaporization rate occurs would cause significant vacuum decay at deep vacuum regardless of the tip ID.

19 CAPILLARY LIQUID FLOW RATE  Liquid defects will similarly affect capillaries.  No sharp edge to simulate natural defect geometry.  The meniscus will produce a liquid surface area the same area of the internal geometry of the capillary.

20 LASER DRILLED DEFECTS Nominal hole size 5 µm “Better resembles natural defects in glass (cracks) and polymers (pinholes).” 1 1 Li, Lei. American Pharmaceutical Review. February 20, 2013. Container Closure Integrity Testing Method Development and Validation for Prefilled Syringes.

21 CONCLUSION A variety of positive control types provide accurate a reliable methods for creating defects for gas filled defects. Micropipettes and capillaries acceptable for gas flow (dry product) leak testing. Use of capillary and pipette defects will provide a unique circumstance, improving the detection capability of liquid defects with deep vacuum based methods.