Download presentation
Presentation is loading. Please wait.
Published byValentine Patrick Modified over 8 years ago
1
Date of download: 7/9/2016 Copyright © 2016 SPIE. All rights reserved. Schematic diagram of the coordinate system; θ is the viewing angle and O.R. represents a typical ray passing through the phase object P.O. Figure Legend: From: New reconstruction algorithm for moiré tomography in flow field measurements Opt. Eng. 2006;45(11):117002-117002-8. doi:10.1117/1.2395922
2
Date of download: 7/9/2016 Copyright © 2016 SPIE. All rights reserved. Schematic diagram illustrating the geometry associated with the calculation of the partial derivative. Figure Legend: From: New reconstruction algorithm for moiré tomography in flow field measurements Opt. Eng. 2006;45(11):117002-117002-8. doi:10.1117/1.2395922
3
Date of download: 7/9/2016 Copyright © 2016 SPIE. All rights reserved. Comparison of the reconstruction obtained by different algorithms: (a) exact temperature distribution, (b) reconstruction by our previous algorithm, and (c) reconstruction by modified ART. Figure Legend: From: New reconstruction algorithm for moiré tomography in flow field measurements Opt. Eng. 2006;45(11):117002-117002-8. doi:10.1117/1.2395922
4
Date of download: 7/9/2016 Copyright © 2016 SPIE. All rights reserved. Comparison of the reconstruction errors resulting from different algorithms: (a) normalized distance errors and (b) maximum value errors. Figure Legend: From: New reconstruction algorithm for moiré tomography in flow field measurements Opt. Eng. 2006;45(11):117002-117002-8. doi:10.1117/1.2395922
5
Date of download: 7/9/2016 Copyright © 2016 SPIE. All rights reserved. Schematic diagram of rotatable deflectometric system. Figure Legend: From: New reconstruction algorithm for moiré tomography in flow field measurements Opt. Eng. 2006;45(11):117002-117002-8. doi:10.1117/1.2395922
6
Date of download: 7/9/2016 Copyright © 2016 SPIE. All rights reserved. Deformed moiré deflectograms recorded at three view angles in the experiment: (a) 0, (b) 60, and (c) 120deg. Figure Legend: From: New reconstruction algorithm for moiré tomography in flow field measurements Opt. Eng. 2006;45(11):117002-117002-8. doi:10.1117/1.2395922
7
Date of download: 7/9/2016 Copyright © 2016 SPIE. All rights reserved. Reconstructed temperature distribution at a designated section. (a) Asymmetric temperature distribution and (b) temperature contour map. Figure Legend: From: New reconstruction algorithm for moiré tomography in flow field measurements Opt. Eng. 2006;45(11):117002-117002-8. doi:10.1117/1.2395922
8
Date of download: 7/9/2016 Copyright © 2016 SPIE. All rights reserved. Schematic diagram of experimental setup. Figure Legend: From: New reconstruction algorithm for moiré tomography in flow field measurements Opt. Eng. 2006;45(11):117002-117002-8. doi:10.1117/1.2395922
9
Date of download: 7/9/2016 Copyright © 2016 SPIE. All rights reserved. Deflectogram of rocket exhausted jet and the designated cross sections for reconstruction. Figure Legend: From: New reconstruction algorithm for moiré tomography in flow field measurements Opt. Eng. 2006;45(11):117002-117002-8. doi:10.1117/1.2395922
Similar presentations
© 2024 SlidePlayer.com Inc.
All rights reserved.