1 COVIDIEN FOR ADVANCED TECHNOLOGIES
Dobromira Ribarova, rsr ltd

2 Ever Flex™ Self-expanding Peripheral Stent with Entrust™ Delivery System
Stent Delivery with Control and Accuracy

3 The EverFlex™ Stent Clinically Proven Performance: DURABILITY II
A proven stent patency rate at one year by Kaplan-Meier analysis(1): Freedom from loss of primary patency 77.2% 86.2% in lesion lengths ≤ 80 mm 69.6% in lesion lengths > 80 mm A low one-year stent fracture rate of 0.4% (1)Data on file. DURABILITY II IDE Study, 287 subjects enrolled.

4 Now the EverFlex™ System is even better
Now the EverFlex™ System is even better... Clinically Proven Performance: DURABILITY II EverFlex™ Self-expanding Peripheral Stent with Entrust™ Delivery System

5 The Entrust™ Delivery System
Low Profile System Without compromise Low 5 F sheath compatible profile with same EverFlex™ stent 150 cm catheter for brachial access 0.035” wire compatible for increased wire support

6 Controlled Delivery and Accurate Deployment
Comfortable, easy-to-use, ergonomic one-handed design Controlled wheel rotation reduces the risk of stent elongation and compression Triaxial design provides increased accuracy for more predictable outcomes

7 More Options in Challenging Anatomies Low 5 F Profile
Smaller puncture site Less time applying pressure1 Reduced need for closure device Quicker ambulatory rates Decreased hospital stays 1 Charles A. Bush, Douglas B. VanFossen, Albert J. Kolibash, Jr. et al. Caridac Catheterization and Coronary Angiography using 5 French Preformed (Judkins) Catheters from the Percutaneous Right Brachial Approach: A Comparative Analysis with the Femoral Approach. Cathet Cardiovasc Diagn. 1993;29:

8 Redesigned Tip for Easier Device Retrieval

9 Robust Choice: Broad Stent Matrix
Stents ranging from 20 mm – 200 mm Minimizes stent overlap during SFA placement

10

11 Innovating to Meet Patient Complexity: Entrust™ Delivery System
Low 5 F profile for more options in challenging patients Easy to use ergonomic one-handed design Triaxial design for increased accuracy Remains on workhorse 0.035” wire without tradeoffs 150 cm catheter for brachial access

12 Avigo .014 gidewire -product overview

13 Navien™ intracranial support catheter advantages

14 Pipeline™ Embolization Device Overview

15 Pipeline™ Embolization Device Clinical Overview
Over 14 series on the Pipeline™ embolization device have been published worldwide 2 Prospective Trials 4 Multi-Center Registries Up to 2 years follow-up time

16 new coil from Axium family
AXIUM Prime new coil from Axium family

17 Thank you!