R. Michaels, JLab PREX Mtg, July 2008 Recent Cavity Monitor Tests Credit: John Musson, Anna Boehle, Vince Sulkosky Good position & current for 10 nA to.

Similar presentations


Presentation on theme: "R. Michaels, JLab PREX Mtg, July 2008 Recent Cavity Monitor Tests Credit: John Musson, Anna Boehle, Vince Sulkosky Good position & current for 10 nA to."— Presentation transcript:

1 R. Michaels, JLab PREX Mtg, July 2008 Recent Cavity Monitor Tests Credit: John Musson, Anna Boehle, Vince Sulkosky Good position & current for 10 nA to 100 uA At 10 nA : Need absolute position to 0.2 mm Need resolution of ~ 0.5 mm (1-shot at 200 nsec) HRS rates ~ 200 kHz  good for Q Goals ~achieved, but need to repeat with a current & position scan with constant gain. 2

2 R. Michaels, JLab PREX Mtg, July 2008 Cavity BPM EPICS Interface (beam off)

3 R. Michaels, JLab PREX Mtg, July 2008 Cavity BPMs correlated to Striplines Spectrometer DAQ High current tests (Jan 2008) Good Saturated gain (oops) Good

4 R. Michaels, JLab PREX Mtg, July 2008 Beam Current correlated to Standard BCMs

5 R. Michaels, JLab PREX Mtg, July 2008 Low - Current ( 50 nA ) Tests Bigbite 8.8 kHz uA deflected beam Target Cavity X,Y,Q Stripline X,Y Steering Coils

6 R. Michaels, JLab PREX Mtg, July 2008 Cavities are calibrated here (1 uA)

7 R. Michaels, JLab PREX Mtg, July 2008 100 nA : Striplines disappear, Cavity positions ~ same

8 R. Michaels, JLab PREX Mtg, July 2008 50 nA: Calibration Changed ! (oops ! Gain adjusted)

9 R. Michaels, JLab PREX Mtg, July 2008 (oops ! Gain adjusted) At 9.5 uA

10 R. Michaels, JLab PREX Mtg, July 2008 Resolution Analysis Method 1: Use 1 BPM as a measure of beam motion on the other. Subtract it off, residual is the resolution (approx).

11 R. Michaels, JLab PREX Mtg, July 2008 50 nA Resolution ~ 400 um 1-shot at 200 nsec. It will be better with averaging

12 R. Michaels, JLab PREX Mtg, July 2008 Resolution Analysis Method 2: Using a line built from other monitors, look at residual to the line. Results comparable to method 1. Position is known much better than the beam pipe diameter !

13 R. Michaels, JLab PREX Mtg, July 2008 Summary -- Cavity Monitors Working well, we have the G0 version of electronics Good signals at 10 nA  Can measure Q Plan to repeat scan ( I beam, X, Y ) with constant gains 2 2